• 제목/요약/키워드: micro-indentation

검색결과 103건 처리시간 0.026초

Comparison of tooth movement and biological response in corticotomy and micro-osteoperforation in rabbits

  • Kim, Junghan;Kook, Yoon-Ah;Bayome, Mohamed;Park, Jae Hyun;Lee, Won;Choi, Hojae;Abbas, Noha H.
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.205-213
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the amount of tooth movement and histologic changes with different corticotomy designs and micro-osteoperforation in rabbits. Methods: The sample consisted of 24 rabbits divided into three experimental groups (triangular corticotomy [TC] and indentation corticotomy [IC] with flap, and flapless micro-osteoperforations [MP]) and a control. A traction force of 100 cN was applied by connecting the first premolars to the incisors. The amount of tooth movement was measured. Kruskal-Wallis test was used to assess differences in tooth movement between the groups. Micro-computed tomography, hematoxylin and eosin staining, and tartrate-resistant acidic phosphatase (TRAP) analysis were performed. Analysis of variance was applied to assess differences in TRAP-positive osteoclast count between the groups. Results: The amount of tooth movement increased by 46.5% and 32.0% in the IC and MP groups, respectively, while the bone fraction analysis showed 69.7% and 8.5% less mineralization compared to the control. There were no significant intergroup differences in the number of TRAP-positive osteoclasts. Conclusions: The micro-osteoperforation group showed no significant differences in the amount of tooth movement compared to the corticotomy groups, nor in the TRAP-positive osteoclast count compared to both corticotomy groups and control.

Effect of Doping Si in DLC Thin Films Growth on Their Mechanical Properties

  • 김대영;박민석;진인태
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.369.2-369.2
    • /
    • 2014
  • Diamond-like Carbon(DLC) films doping Si were deposited by linear ion source(LIS)-physical vapor deposition method on Si wafer. We have studied the effects of Si content on friction and wear properties of DLC films and the characteristics of the films were investigated using Nano-indentation, Micro raman spectroscopy, Field Emission-Scanning Electron Microscope (FM-SEM) and X-ray Photoelectron Spectroscopy (XPS). The films has been various low-friction and low-stress by varying the flow rates of silane gas. Under the about 2% of Si doping is very suitable for improving the adhesion of films and reducing internal stress while maintaining the surfaces hardness of DLC films. Linear ion source (LIS)를 사용하여 Si wafer위에 Si 이온이 첨가된 DLC 박막을 증착하였다. 참가된Si 이온의 양에 따라 DLC 박막에 미치는 영향을 분석하기 위하여 마찰 계수 및 경도를 비교하였고, Micro raman spectroscopy, Field Emission-Scanning Electron Microscope (FM-SEM) and X-ray Photoelectron Spectroscopy (XPS)를 통하여 표면 상태를 분석하였다. 천체 주입된 가스량의 약 2%까지 Si 이온 주입이 늘어날수록 DLC 박막의 마찰계수는 낮아졌고, 경도는 Si 이온이 주입되지 않았을 경우와 비슷한 값(약 20~23 GPa)을 가졌다. 2% 이상의 주입량에서는 마찰계수는 주입량이 늘어날수록 높아졌으며 경도는 떨어지는 경향을 보였다. 이는 Si이온이 2%이하로 첨가되었을 경우, DLC 박막의 생성시 탄소 이온들의 결합 Stress를 줄여 마찰계수가 줄어든다고 볼 수 있으며, 그 양이 2%이상이 되면 오히려 불순물로 작용하여 DLC 박막의 Stress는 급격히 증가하고 마찰계수도 높아짐을 알 수 있다.

  • PDF

Effects of ceramic fillers on fracture resistance of barrier ribs of PDP

  • Baek, Se-Kyung;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.552-554
    • /
    • 2004
  • Barrier ribs of plasma display panel (PDP) are glass matrix composite reinforced with alumina particles. Mechanical properties of the ribs are very crucial for the improvement in reliability of the panel as the ribs might fracture during transportation and service. In this study, therefore, the effects of filler type and content on the mechanical properties of the ribs were investigated. The fillers used include $Al_2O_3$, $TiO_2$, $ZrO_2$ and fused silica. The content of the filler was changed from 0 to 40 vol.%. The mechanical properties of the ribs measured were hardness, Young's modulus, fracture toughness, and 3-point bending modulus. The fracture toughness evaluated by micro-Vicker's indentation of the composites, in general, was measured to increase with the content of the filler until the sintered density does not decrease significantly. The improvement, however, was dependent on the type of filler employed.

  • PDF

Micro Indentor를 이용한 Stiction Free Slider 개발 (Fabrication and Investigation of a Method of the Reduced-Stiction Slider)

  • 박준우;김대은
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.842-845
    • /
    • 2000
  • It is essential to reduce stiction between the slider and the disk for super-smooth media such as glass disk for high density recording. We developed a stiction-reduced slider by fabricating mechanical bumps on the air bearing surface of the slider by indentation technique. This paper presents a possibility and concept of Stiction-Free-Slider which can operate on the data zone of a magnetic disk. The slider hat many bumps and their heights are in the tens of nm range. The SFS shows good performance on the data zone. Moreover, little wear of the bumps was observed when the preload was small.

  • PDF

Improvement of Adhesion Strength of DLC Films on Nitrided Layer Prepared by Linear Ion Source

  • Shin, Chang-Seouk;Kim, Wang-Ryeol;Park, Min-Seok;Jung, Uoo-Chang;Chung, Won-Sub
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.177-179
    • /
    • 2011
  • The purpose of this study is to enhance an adhesion between substrate and Diamond-like Carbon (DLC) film. DLC has many outstanding properties such as low friction, high wear resistance and corrosion resistance. However, it is difficult to achieve enough adhesion because of weak bonding between DLC film and the substrate. For improvement adhesion, a layer between DLC film and the substrate was prepared by dual post plasma. DLC film was deposited on nitrided layer by linear ion source. The composed compound layer between substrate and DLC film was investigated by Glow Discharge Spectrometer (GDS) and Scanning Electron Microscope (SEM). The synthesized bonding structure of DLC film was analyzed using a micro raman spectrometer. Mechanical properties were measured by nano-indentation. In order to clarify the mechanism for improvement in adhesive strength, it was observed by scratch test.

  • PDF

광화마그마내에서의 백금, 안티모니, 테루리움 거동에 관한 연구(I) (Behavior of Pt, Sb, Te during Crystallizaion of Ore Magma (I))

  • 김원사
    • 한국광물학회지
    • /
    • 제9권2호
    • /
    • pp.93-101
    • /
    • 1996
  • Behavior of platinum group elements during crystallization within ore magma is of interest. In this study platinum is selected and its mineralogical and geochemical behavior in the presence of antimony and tellurium is investigated at 600$^{\circ}C$. High purity Pt, Sb, and Te are used as starting material and silica quartz tubings are as container. Rection products have been examined by use of ore microscope, X-ray diffractometer, electron microprobe analyser and micro-indentation hardness tester. stable phases at 600$^{\circ}C$ are platinum (Pt), Pt5Sb, Pt3Sb, PtSb, stumpflite (PtSb), geversite (PtSb), PtTe, Pt3Te4, Pt2Te3, moncheite (PtTe2), tellurantimony (Sb2Te3), and antimony (Sb). Geversite is the mineral showing the most significant extent of solid solution by up to 27 at% between Sb and Te elements. Isothermal section of 600$^{\circ}C$ is established in this study. It is noted that platinum cannot coexists with stumpflite or geversite under equilibrium condition, and stumpflite composition in equilibrium with geversite may be used as geothermometer.

  • PDF

Influence of Electric Poling an Fracture Toughness of Ferroelectric-Ferroelastic PZT Ceramics

  • Zuokai Ke;Sunggi Baik
    • The Korean Journal of Ceramics
    • /
    • 제1권4호
    • /
    • pp.197-203
    • /
    • 1995
  • Nearly fully dense PZT samples both with tetragonal and with morphotropic phase boundary compositions were prepared by the conventional powder processing and sintering. A micro-indentation technique was used to evaluate the dependence of fracture toughness on remanent polarization, crack length and the direction of crack propagation. The result shows that the toughness increases with the remanent polarization along the poling direction and decreases in the transverse direction. The dependence of toughness on the remanent polarization is neither symmetric nor linear but rather shown to be saturated quickly with the increase in remanent polariztion. R-curve behaviors are observed in both poled and unpoled samples. Sequential SEM and XRD studies on annealed, poled, ground, fractured and etched samples show that domain switching is evident as a viable toughening mechanism but might depend upon the rate of crack propagation. Grain bridging is also observed as one of the active toughening mechanisms.

  • PDF

음향방출과 다구찌 방법을 이용한 나노머시닝 가공조건의 최적화 (Optimization of Nano Machining Parameters Using Acoustic Emission and the Taguchi Method)

  • 이성환;손정무
    • 한국정밀공학회지
    • /
    • 제21권3호
    • /
    • pp.163-170
    • /
    • 2004
  • Atomic force microscope (AFM) techniques are increasingly used fur tribological studies of engineering surfaces at scales ranging from atomic and molecular to micro-scale. Recently, AFM with suitable tips is being used for nano fabrication/nano machining purposes. In this paper, machining characteristics of silicon were investigated by nano indentation and nano scratch. Nano-scale material removal mechanisms are studied and the Taguchi method was introduced to acquire optimum parameters for nano machining. Also, Acoustic Emission (AR) is used for the monitoring of nano machining.

Novel characterisation methods for Polymer Applications

  • Bailey, R.S.;McNicol, A.;Lambert, P.
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.142-143
    • /
    • 2006
  • Combinatorial methods are being used increasingly to develop the next generation of polymers, coatings and adhesive formulations. Allied to this approach, a new genre of measurement and characterization methods are emerging. These characterization techniques are required to handle and take measurements from small samples. This has led to a number of uses for this technology which usefully fall between convention test specimen and micro- or nano-scale test methods. A versatile measurement platform will be presented which can offer useful indentation, puncture, compression, adhesion and scratch resistance data for a wide variety of material types and that continues to develop and evolve in capability.

  • PDF