• Title/Summary/Keyword: micro-degree

Search Result 409, Processing Time 0.027 seconds

The establishment of requirement and kinematic analysis of mechanism for deployable optical structure (전개형 광학구조체용 메커니즘 요구조건 수립 및 후보 메커니즘의 기구학적 해석)

  • Jeong, Seongmoon;Choi, Junwoo;Lee, Dongkyu;Hwang, Kukha;Kim, Sangwoo;Kim, Jangho;Kim, Byungkyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.701-706
    • /
    • 2014
  • In these days, there have been numerous researches on nano and micro satellites under the slogan of "Faster, Smaller, Better, Cheaper". Since optical structure occupies large portion of satellite volume, research on deployable optical structure gains great attention to reduce total volume of the satellite. In this paper, we establish the requirement of deployable optical structure based on specification of conventional optical structure and propose two candidate mechanisms which can satisfy the degree of deployment precision. Then, in order to evaluate the degree of deployment precision, we carry out kinematic analysis on de-space among tilt, de-space and de-center which influences optical characteristic of a satellite.

Antigenicity of Protein Entrapped in Poly(lactide-co-glycolide) Microspheres (폴리락티드-글리콜리드 마이크로스피어에 봉입된 단백질의 항원성 평가)

  • Song, Seh-Hyon;Cho, Seong-Wan;Shin, Taek-Hwan;Yoon, Mi-Kyoung;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.3
    • /
    • pp.191-196
    • /
    • 2001
  • Biodegradable polymeric microspheres were studied for their usefulness as carriers for the delivery of vaccine antigens. However, protein antigen could be denatured during microencapsulation processes due to the exposure to the organic phase and stress condition of cavitation and shear force. Therefore this study was carried out to re-evaluate the degree of protein denaturation during microencapsulation with poly(lactide-co-glycolide) (PLGA) copolymer. PLGA microspheres containing ovalbumin (OVA), prepared by W/O/W multiple emulsification method, were suspended in pH 7.4 PBS and incubated with shaking at $37.5^{\circ}C$. Drug released medium was collected periodically and analyzed for protein contents by micro-BCA protein assay. In order to evaluate the protein integrity, release medium was subjected to the analyses of SDS-PAGE and size exclusion chromatography (SEC). And enzyme-linked immunosorbent assay (ELISA) was introduced to measure the immunoreactivity of entrapped OVA and to get an insight into the three-dimensional structure of epitope. The structures of entrapped protein were not affected significantly by the results of SDS-PAGE and SEC. However, immunoreactivity of released antigen was varied, revealing the possibility of protein denaturation in some microspheres when it was evaluate by ELISA method. Therefore, in order to express the degree of protein denaturation, antigenicity ratio (AR) was obtained as follows: amount of immunoreactivity of OVA/total amount of OVA released ${\times}100(%)$. ELISA method was an efficient tool to detect a protein denaturation during microencapsulation and the comparison of AR values resulted in more accurate evaluation for immunoreactivity of entrapped protein.

  • PDF

Effect of Lymphangiogenic Factors on Survival in a Murine Model of Oral Squamous Cell Carcinoma (구강암 마우스모델에서 림프관형성 인자가 생존율에 미치는 영향)

  • Park, Young-Wook;Cho, Ju-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.1-12
    • /
    • 2013
  • Purpose: Vascular endothelial growth factor (VEGF)-C and its tyrosine kinase receptor, VEGF receptor (VEGFR)-3 are recently known to have lymphangiogenic activities in various tumor types. In this study, we determined whether the expression of lymphangiogenic factors correlate with nodal metastasis or survival in a nude mouse model of oral squamous cell carcinoma (OSCC). Methods: Three OSCC cells (KB, SCC4, SCC9) were xenografted into the right mandibular gland of athymic nude mice. The mice were followed for tumor development and growth, and the mice were sacrificed when they had lost more than 20% of their initial body weight, or the diameter of the induced tumor exceeds 20 mm. After necropsy, the murine tumors were examined histologically and radiologically (micro-positron emission tomography computed tomography) for regional or distant metastasis. We performed immunohistochemical assays with anti-VEGF-C, VEGFR-3, CD105, and D2-40 antibodies. Immunofluorescence double staining for LYVE-1/CD31 was also performed. To quantify the VEGF-C and VEGFR-3 level in the cancer tissue, Western blotting was performed. Finally, we determined the correlation between the degree of expression of VEGF-C/VEGFR-3 and the mean survival time. Results: OSCC tumor cells into the mandibular gland of the nude mice successfully resulted in the formation of recapitulating orthotopic tumor. Tumor cells of the induced tumor did not express VEGF-C. VEGF-C/VEGFR-3 expression was mainly distributed in the endothelial cells of the stromal area. There were no correlation between the degree of expression of VEGF-C/VEGFR-3 and the mean survival time of mice injected with different OSCC cell lines. Conclusion: An recapitulating orthotopic model of OSCC in nude mice was established, which copies the cervical nodal metastasis of human OSCC. Overexpression of lymphangiogenic factors seems to have no effect on survival of hosts in this in vivo experiment.

Degradation Degree Evaluation of Heat Resisting Steel by Electrochemical Technique Part 2 : Effect of Testing Conditions on Evaluation Value of Degradation Degree and Changes of Mechaical Properties (전기화학적 방법에 의한 내열강의 열화도측정 제2보 : 열화도측정치에 미치는 측정조건들의 영향과 기계적성질 변화에 대해서)

  • 정희돈;권영각;장래웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.300-312
    • /
    • 1993
  • The material deterioration of service-exposed boiler tube steels in fossil power plant was evaluated by using the electrochemical technique namely, modified electrochemical potentiokinetic reactivation(EPR). It was focused that the passivation of Mo$_{6}$C carbide which governs the mechanical properties of Mo alloyed steels did not occur even in the passivity region of steel in sodium molybdate solution and the reactivation peak current (Ip) observed as the result of non-passivation indicating the precipitation of Mo$_{6}$C carbides. To obtain the optimal test conditions for the field test by using the specially designed electrochemical cell, the effects of scan rate, the surface roughness and the pH of electrolyte on Ip value were also investigated. Furthermore, the change of mechanical properties occurred during the long time exposure at high temperature was evlauated quantitatively by small punch(SP) tests and micro hardness test taking account of the metallurgical changes. It is known that reactivation peak current (Ip) has a good relationship with Larson-Miller Parameter(LMP) which represents the information about material deterioration occurred at high temperature environment. In addition it was possible to estimate the ductile-brittle transition temperature (DBTT) by means of the SP test. The Sp test could be, therefore, suggested as a reliable test method for evaluating the material degradation of boiler tube steels. From the good correaltion between the SP DBTT and Ip values shown in this study, it was knows that the change of mechanical properties could be evaluated non-destructively by measurring only Ip values.ues.

Evaluation of the $\sigma$-Phase Degradation for Cast Stainless Steel CF8M by the Electrochemical Method (전기화학적 방법에 의한 주조 스테인리스강 CF8M $\sigma$상 열화평가)

  • Gwon, Jae-Do;Kim, Jung-Hyeong;Park, Jung-Cheol;Byeon, Jang-Hwan;Lee, U-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.2014-2021
    • /
    • 1999
  • The present investigation is concerned with the degradation characteristics of cast stainless steel(CF8M), exposed to the $\sigma$-phase degradation at $700^{\circ}C$. In the present paper, the degradation of CF8 M at $700^{\circ}C$ is evaluated by a non-destructive test, DL-EPR(double loop electrochemical potentiokinetic reactivation). The surface of specimens is observed by using scanning electron microscopy after DL-EPR test. Also. chromium contents of matrix, grain boundary and ferrite phase are analyzed by electron probe X-ray micro analyzer. Through the experiments, the following results are obtained 1) The degree of sensitization(DOS) of CF8M aged up to 15hr at $700^{\circ}C$ is increased with acing time while that is decreased with aging time from 15hr to 150hr. 2) The impact energy decreases with increase of $\sigma$-phase while DOS increases with $\sigma$-phase until aging time reaches to 15hr. After the aging time. 15hr, the $\sigma$-phase and the rate of impact energy with respect to aging time decreases. Therefore the degradation behavior of the CF8M can be evaluated by comparing SEM micrographs and the value of DOS.

The Limit of the Continuum Assumption Based on Compressible Flow Structures in an Axisymmetric Micro-Thruster Used for a Satellite (인공위성용 축대칭 소형 추력기의 압축성 유동 구조 계산에 의한 연속체 가정의 적용 한계)

  • Kwon, Soon-Duk;Kim, Sung-Cho;Kim, Jeong-Soo;Choi, Jong-Wook;Lee, Kee-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.281-285
    • /
    • 2007
  • The flow characteristics in the thruster should be analyzed considering its geometry and the pressure ratio to estimate its performance and etc. This paper suggests the computational result of an axisymmetric real nozzle for the altitude control of a satellite to find out the application limit that the assumption of continuum mechanics holds. The steady non-reacted compressible flow field in the unstructured grid system is computed and analyzed with varying the environmental pressure (or the degree of vacuum) under the fixed pressure ratio in a real thruster of which the area ratio of exit to throat is 56. The assumption of the continuum mechanics is not approved when the environmental pressure is reduced less than $10^{-3}$ atm.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTHS AND MICROLEAKAGES OF THREE BONDING AGENTS ON DENTIN (상아질 접착제의 전단결합강도와 미세누출에 관한 연구)

  • Kim, Jeong-Ho;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.680-692
    • /
    • 1997
  • New bonding agent systems have been supplied which operators can simply apply to conditioned tooth surfaces. The purpose of this study was to evaluate the shear bond strengths and the microleakages of three bonding agents and composite resins to dentin. Seventy-five extracted human maxillary and mandibular molar teeth were used in this study. For the shear bond strength test, the entire occlusal dentin surfaces of thirty teeth were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A). For the microleakage test, Class V cavities were prepared in the buccal surfaces of fourtyfive teeth. They were randomly assigned into 3 groups according to dentin bonding agents ($Scotchbond^{TM}$ Multi-Purpose plus, ONE-$STEP^{TM}$ and Prime & $Bond^{TM}$)and composite resins (Z-100, $Aelitefil^{TM}$ and TPH $Spectrum^{TM}$) to be used. Bonding agents and composite resins were bonded to exposed dentin surfaces of the tooth crown and to Class V cavities on the buccal surfaces respectively according to manufacturer's directions. The shear bond strengths were measured by universal testing machine($U^{TM}$ AGS-100, Japan). In addition, the degree of micro leakage at the occlusal and gingival margin was examined by 2 % methylene blue and stereomicroscope(Olymous SZH 10, Japan). The results were as follows: 1. The shear bond strength to dentin was the highest value in SBMP-Plus group($16.68{\pm}7.38$ MPa) and the lowest value in Prime & Bond group($11.61{\pm}5.82$ MPa), but there was no significant difference of shear bond strength among three groups. 2. The degree of microleakage at both occlusal and gingival margin was showed the lowest in SBMP-Plus group and the highest in ONE-STEP group. 3. At both occlusal and gingival margin, there was significant difference of microleakage between SBMP-Plus and ONE-STEP/ Prime & Bond groups(p<0.05), but no significant difference of microleakage between ONE-STEP and Prime & Bond group(p>0.05).

  • PDF

The Evaluation of the thermal degradation and the degree of cure of glass/epoxy composite by ultrasonic technique (복합재료의 열화도 및 경화도에 따른 초음파 특성 연구)

  • 강길호;최원종;박상윤
    • Composites Research
    • /
    • v.16 no.6
    • /
    • pp.33-40
    • /
    • 2003
  • The initial thermal degradation of polymer matrix composite is not observed easily. At the beginning of thermal degradation of polymer matrix composites, phase transformation such as chain scission, oxidation occur, and then micro delamination is produced in matrix and interface between matrix and fiber before blistering. Initial heat damage deteriorate mechanical properties of composites. We presented the detection method of the initial heat damage of composites conveniently using ultrasonic technique. Absorption coefficient and material velocity was measured with thermal degradation and degree of cure. The more thermal degradation was progressed, the more absorption coefficient was increased. When the cure temperature is more high, the absorption coefficient of cured composite is increased and material velocity is decreased. We concluded that cure temperature is more high, the defects such as void is increased and molecular structure cured at high temperature has cross-linking structure which is more absorb the ultrasonic waves.

A STUDY ON THE APICAL MICROLEAKAGE OF GLASS IONOMER ROOT CANAL SEALER (Glass Ionomer Root Canal Sealer의 치근단 미세누출에 관한 연구)

  • Lee, So-Young;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.236-246
    • /
    • 1998
  • The purpose of this study was to compare the degree of micro- leakage of new glass ionomer root canal sealer, Ketac-Endo(ESPE Co., Seefeld, Germany) with that of AH-26(De Trey Co., Ltd., U.S.A.). Root canal treatment using K -file, H -file, Gate Glidden drill was conducted on 49 extracted single-rooted teeth. 45 teeth were randomly divided into 3 experimental groups(15 teeth per group) and 4 teeth were used as the control group. Group 1 was used AH -26 sealer with the lateral condensation method for canal filling, group 2 was used Ketac-Endo with the single cone method and group 3 was used Ketac-Endo with the lateral condensation method. The control group was obturated with the single cone method without sealer. The teeth were covered with two coats of nail varnish after 48 hours of obturation. The teeth were immersed in India ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows: 1. 7 teeth in group 1, 5 in group 2, and 3 in group 3, were showed evidence of microleakage implying appropriate canal filling. 2, The mean average of microleakage was $0.17{\pm}0.32mm$ in group 1, $0.30{\pm}0.37mm$ in group 2. $0.10{\pm}0.21mm$ in group 3, showing that canal filling using the lateral condensation canal filling method with Ketac-Endo showed the least microleakage and using the single cone method with Ketac-Endo showed the largest amount of microleakage, 3. There were no statistically significant difference in the variation of microleakage among groups. From the results above, Ketac-Endo which has the advantage of glass ionomer, whether using the single cone method or the lateral condensation method, showed similar results as AH-26, but for clinical application it is thought that were studies on the properties of Ketac-Endo should be followed.

  • PDF

Development of MEMS Sensor-based High Resolution Tilt Monitoring System (MEMS 센서 기반 고정밀 기울기 모니터링 시스템 설계)

  • Son, Young-Dal;Eun, Chang-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1364-1370
    • /
    • 2019
  • Tilt sensors are mainly used to measure the collapse of structures such as buildings, bridges and tunnels. Recently, due to the ease of use and low price, many tilt sensors using MEMS sensors have been used, but the measurement angle range is limited, and thus, they do not have high precision for 360 degree. This is due to the inherent offset and scale errors of MEMS sensors. In this paper, we proposed an algorithm for the calculation of precision angles to reduce the mechanical error of MEMS sensors, and produced a MEMS sensor module and a transmission module to compare the angle accuracy of sensor modules before calibration and the angle measurement accuracy after calibration. Experimental results show that the proposed technique has a precision of ± 0.015 degrees for all 360-degree.