• Title/Summary/Keyword: micro parts

검색결과 661건 처리시간 0.027초

압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구 (Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model)

  • 김동현;오일근
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

해양 플랜트 배관용 이종 소재(A105-A312) 및 이종 형상 마찰용접의 용접 특성 분석에 대한 연구 (A Study on Weld Characteristics Analysis of Dissimilar Material (A105-A312) and Shape Friction Welding for Marine Plant Piping)

  • 공유식;김태완;곽재섭;안용식;박영환
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.29-35
    • /
    • 2020
  • This paper studies the main parameters of tube-to-bar dissimilar material and shape friction welding for piping materials. The weldability of joint parts was investigated with respect to tensile tests, micro-Vickers hardness, the bond of area, and optical microstructure. The specimens are tested as-welded. Optimal welding conditions are n = 2000 rpm, HP = 50 MPa, UP = 100 MPa, HT = 5 sec, and UT = 10 sec when the metal loss (Mo) is 11 mm. Moreover, the same two materials for friction welding are strongly mixed with a well-combined structure of micro-particles without any molten material, particle growth, or defects. Therefore, the expected result of dissimilar material friction welding includes a reduction of cost and material in the welding process.

휴대폰용 2인치 LCD-BLU의 광특성에 미치는 음각 및 양각 광학 패턴의 영향 연구 : II. 금형 및 광특성 (A Study on the Effect of Optical Characteristic in 2 inch LCD-BLU by Negative and Positive Optical Pattern : II. Mold and Light Characteristics)

  • 황철진;고영배;김종선;민인기;유재원;윤경환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.339-340
    • /
    • 2006
  • Recently, many researches have been done to improve optical performance of LCD-BLU(Back Light Unit). One of the most important parts in LCD-BLU is LGP(Light Guiding Plate). Micro-patterned LGP is known to have different optical characteristics depending on their shape, pattern density and size, etc. In the present study, a micro-optical patterned LGP mold was fabricated using LiGA process. The difference in the optical characteristics between positive and negative patterned LGP's was investigated by fixing the density, location and size of each pattern. It was found that the negative patterned LGP showed better optical characteristics than positive one.

  • PDF

Implantable Drug Delivery Systems-Design Process

  • Vincent, Croquet;Benolt, Raucent;Onori, Mauro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권4호
    • /
    • pp.40-46
    • /
    • 2006
  • The market of programmable implantable pumps has bound to a monopolistic situation, inducing high device costs, thus making them inaccessible to most patients. Micro-mechanical and medical innovations allow improved performances by reducing the dimensions. This affects the consumption and weight, and, by reducing the number of parts, the cost is also affected. This paper presents the procedure followed to design an innovative implantable drug delivery system. This drug delivery system consists of a low flow pump which shall be implanted in the human body to relieve pain. In comparison to classical known solutions, this pump presents many advantages of high interest in both medical and mechanical terms. The first section of the article describes the specifications which would characterize a perfect delivery system from every points of view. This concerns shape, medication, flow, autonomy, biocompatibility, security and sterilization ability. Afterwards, an overview of existing systems is proposed in a decisional tree. Positive displacement motorized pumps are classified into three main groups: the continuous movement group, the fractioned translation group and the alternative movement group. These systems are described and the different problems which are specific to these mechanisms are presented. Since none of them fully satisfy the specifications, an innovation is justified.. The decisional tree is therefore extended by adding new principles: fractioned refilling and fractioned injection within the fractioned translation movement group, spider guiding system within the alternative translation movement group, rotational bearing guided device and notch hinge guided device in the alternative rotation movement group.

초정밀 가공기용 마이크로 스테이지의 힌지 형상에 따른 안정성 해석 (Stability Analysis According to Hinge Type Alteration on Micro Stage for Micro Cutting Machine)

  • 김재열;곽이구;심재기;안재신;송경석;한재호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.993-998
    • /
    • 2002
  • Ultra precision processing technology is the field which is seriously protected its technology by advanced nations. Because of this reason, this technology is very difficult to supply for domestic companies, also domestic companies are revealed the limit of technology development by itself. And then, those are depend on the technology development of advanced nation, domestic companies are not conquer application step with already developed parts. Of course, some cases of its research are succeed. those are included element technology, system technology and so on, for development of ultra precision processing system. To conquer technology holding ultra precision processing accuracy of no level, active research are needed. In this paper, stability of ultra precision cutting unit is analyzed, this unit is the kernel unit in ultra precision processing machine. According to alteration of shape and material about hinge, stability investigation is performed Through this stability investigation, trial and error is reduced in design and manufacture, at the same time, we are accumulated foundation data for un it control.

  • PDF

Epigenetics: A key paradigm in reproductive health

  • Bunkar, Neha;Pathak, Neelam;Lohiya, Nirmal Kumar;Mishra, Pradyumna Kumar
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제43권2호
    • /
    • pp.59-81
    • /
    • 2016
  • It is well established that there is a heritable element of susceptibility to chronic human ailments, yet there is compelling evidence that some components of such heritability are transmitted through non-genetic factors. Due to the complexity of reproductive processes, identifying the inheritance patterns of these factors is not easy. But little doubt exists that besides the genomic backbone, a range of epigenetic cues affect our genetic programme. The inter-generational transmission of epigenetic marks is believed to operate via four principal means that dramatically differ in their information content: DNA methylation, histone modifications, microRNAs and nucleosome positioning. These epigenetic signatures influence the cellular machinery through positive and negative feedback mechanisms either alone or interactively. Understanding how these mechanisms work to activate or deactivate parts of our genetic programme not only on a day-to-day basis but also over generations is an important area of reproductive health research.

동력분산형 고속철도의 공력해석기술 연구 (Study on the Aerodynamic Analysis of the High-Speed EMU)

  • 노주현;구요천;윤수환;곽민호;박훈일;김규홍;이동호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1166-1171
    • /
    • 2008
  • Through Korean high speed train development project "G7 Leading Technology Development Project" from 1996 to 2002, HSR-350X has been developed. It can run the maximum operating speed of 350 km/h. Based on this technology, KTX-2 which will be served commercially has been developed till 2007. This paper introduces the aerodynamic analysis of the High-Speed EMU and shows the results of optimized aerodynamic nose shape design techniques and clean pantograph panhead original techniques study. These are the important parts of developments for high speed train which maximum speed is 400 km/h. Especially for decrease of tunnel micro pressure waves, the optimized nose area distributions were derived and the characteristics of micro pressure wave were analyzed. The robust optimized pantograph panhead shapes investigated to improve the performance and decrease the vortex flow which is thought to be its noise source. These shapes are clean and robust to external disturbances like unsteady accelerated flow or side wind was derived. Finally aerodynamic performances was verified with PIV and smog visualization by wind tunnel test.

  • PDF

실리콘 광벤치 및 자동 광섬유/필터 정렬시스템을 이용한 극소형 광통신용 Add/Drop 모듈의 설계 제작 및 실험 (Design, Fabrication and Test of the Micro Optical Add/Drop Module Using Silicon Optical Bench and Automatic Optical Fiber/Filter Alignment System)

  • 최두선;박한수;서영호;김성곤;제태진;황경현
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.211-215
    • /
    • 2004
  • Recently, one of remarkable tends in the development of optical communication industry is the miniaturization and integration of products. The alignment system of micro optical module is a key apparatus for the miniaturization of optical module and the development of optical communication parts with high functionality. In this research, we have developed a system capable of automatic alignment of a $30\mu\textrm{m}$-thick film filter and a lensed fiber in order to improve the speed and losses in the optical fiber-to-filter alignment of optical modules. Using the developed automatic alignment system and silicon optical bench, we have measured optical loss and characteristics of the assembled optical add/drop module before packaging $1{\times}1$ OADM optical module. Whole size of add/drop module was less than $5mm{\times}5mm{\times}1mm$. The measured maximum insertion loss was 0.294㏈ that is below 0.3㏈ which is a standard loss of optical module.

HR polishing에 의한 광경화성수지 성형용 글래스 몰드의 투과율 및 표면품위 향상 (Improvement of Transmittance and Surface Integrity of Glass Mold for light-hardening polymer Using MR Polishing)

  • 이정원;김동우;조명우
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.78-83
    • /
    • 2009
  • In general, Light-hardening polymer was used UV nanoimprint technology. A light-hardening polymer was had the problem of poor hardness, durability. In order to overcome the problem of polymer, inter change optical glass. However glass is very manufacture and a lowering of standars transmittance. In order to glass recover was necessary polishing process. The process is magnetorheological fluids polishing. MR polishing has been developed as a new precision finishing technique to obtain a fine surface. Hence, Magnetorheological fluids has been used for micro polishing to get micro parts. This polishing process guarantees high polishing quality by controlling the fluid density electrically. The applied material in experiments is fused silica glass. Fused silica glass is widely used in the optical field because of high degree of purity. For MR polishing experiments, MR fluid was composed with DI-water, carbonyl iron and nano slurry ceria. The wheel speed and electric current were chosen as the variables for analyzing the characteristics of MR polishing process. Outstanding surface roughness of Ra=1.58nm was obtained on the fused silica glass specimen. And originally glass transmittance was recover on the fused silica glass.

  • PDF

전해니켈도금된 대면적 롤금형 가공시 단결정 다이아몬드공구의 마모에 관한 연구 (Wear of Single Crystal Diamond(SCD) Tools in Ultra Precision Turning of Electro-Nickel Plated Drum)

  • 이동윤;홍상현;강호철;최헌종;이석우
    • 대한기계학회논문집A
    • /
    • 제33권7호
    • /
    • pp.621-628
    • /
    • 2009
  • Nickel-phosphorus alloys are attractive materials for diamond turning applications such as fabrication of large optics and other high precision parts. It is also well-known that the higher phosphorus content of the alloys minimizes the diamond tool wear. Due to the weakness of electoless nickel plating that the phosphorus contents is limited to 13-14% (wgt), increased attention has been paid at electro-nickel plating which enables the alloys with 15-16% phosphorus. In this study, experiments were carried out to observe the wear characteristic of single crystal diamond tools in micro-grooving of electro-nickel plated drums. The experiments shows that long distance (50km) machining of micro-grooving on electro-nickel plated drum is possible with a single crystal diamond tool without any significant tool wear and defective machined surface.