• 제목/요약/키워드: micro chamber

검색결과 242건 처리시간 0.025초

Thrust Performances of a Very Low-Power Micro-Arcjet

  • Hotaka Ashiya;Tsuyoshi Noda;Hideyuki Horisawa;Kim, Itsuro ura
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.611-616
    • /
    • 2004
  • In this study, microfabrication of a micro-arcjet nozzle with Fifth-harmonic generation Nd:YAG pulses (wavelength 213 nm) and its thrust performance tests were conducted. A micro-arcjet nozzle was machined in a 1.2 mm thick quartz plate. Sizes of the nozzle were 0.44 mm in width of the nozzle exit and constrictor diameter of 0.1 mm. For an anode, a thin film of Au (~100 nm thick) was deposited by DC discharge PVD in vacuum on divergent part of the nozzle. As for a cathode, an Au film was also coated on inner wall surface. In operational tests, a stable discharge was observed for mass flow of 1.0mg/sec, discharge current of 6 ㎃, discharge voltage of 600 V, or 3.6 W input power (specific power of 3.6 MW/kg). In this case, plenum pressure of the discharge chamber was 80 ㎪. With 3.6 W input power, thrust obtained was 1.4 mN giving specific impulse of 138 sec with thrust efficiency of 24 %.

  • PDF

의료용 도뇨관 표면의 도선용 구리 박막 증착을 위한 스퍼터링-열증착 연속공정장비의 설계 및 개발 (Design and Development of Sputter-evaporation System for Micro-wiring on Medical Catheter)

  • 장준근;정석
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.62-71
    • /
    • 1999
  • Integrating micro-machined sensors and actuators on the conventional devices with the copper power lines was incompatible to fabricate the mass produced micro electromechanical system (MEMS) devices. To achieve the compatibility of the wiring method between MEMS parts and devices, we developed the three-dimensional sputter-evaporation system that coats micropatterned thin copper films on the surface of the MEMS element. The system consists of a process chamber, two branch chambers, the substrate holder, and a linear-rotary motion feedthrough. Thin copper film was sputtered and evaporated on the biocompatible polymer, Pellethane$^{circed{R}}$ and silicone, catheter that is 2 mm in diameter and 700 mm in length. The metal film coating technique with three-dimensional thin film sputter-evaporation system was developed to apply the power and signal lines on the micro active endoscope. In this paper, we developed the three-dimensional metal film sputter-evaporation system operated on the low temperature for the biopolymeric substrates used in the medical MEMS devices.

  • PDF

후면기공을 갖는 마이크로스피커와 덕트형 스피커시스템사이의 연관성 해석 (Analysis of the Relation Between Micro-Speaker with the Back Holes and the Ducted Speaker-System)

  • 이에스더;오세진
    • 한국음향학회지
    • /
    • 제26권3호
    • /
    • pp.115-122
    • /
    • 2007
  • 본 연구에서는 마이크로스피커의 구조와 특성을 유닛과 덕트형 인클로저로 구성되어 있는 일종의 덕트형 스피커시스템처럼 취급할 수 있음을 처음으로 보여주었다. 후면기공의 면적이 증가할수록 스티프니스는 감소하고 컴플라이언스는 증가하였다. 그 결과로써, 후면기공의 면적이 증가할수록 공명진동수가 컴플라이언스의 제곱근에 비례하여 증가하였다. 후면기공의 면적이 감소함에 의하여 중저음 영역에서의 기준음압레벨이 지수함수적으로 감소하였다.

마이크로/나노 핸들링을 위한 마이크로 로보틱 플랫폼: 비전 기반 3자유도 절대위치센서 개발 (A Micro-robotic Platform for Micro/nano Assembly: Development of a Compact Vision-based 3 DOF Absolute Position Sensor)

  • 이재하;;;양승한
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.125-133
    • /
    • 2010
  • A versatile micro-robotic platform for micro/nano scale assembly has been demanded in a variety of application areas such as micro-biology and nanotechnology. In the near future, a flexible and compact platform could be effectively used in a scanning electron microscope chamber. We are developing a platform that consists of miniature mobile robots and a compact positioning stage with multi degree-of-freedom. This paper presents the design and the implementation of a low-cost and compact multi degree of freedom position sensor that is capable of measuring absolute translational and rotational displacement. The proposed sensor is implemented by using a CMOS type image sensor and a target with specific hole patterns. Experimental design based on statistics was applied to finding optimal design of the target. Efficient algorithms for image processing and absolute position decoding are discussed. Simple calibration to eliminate the influence of inaccuracy of the fabricated target on the measuring performance also presented. The developed sensor was characterized by using a laser interferometer. It can be concluded that the sensor system has submicron resolution and accuracy of ${\pm}4{\mu}m$ over full travel range. The proposed vision-based sensor is cost-effective and used as a compact feedback device for implementation of a micro robotic platform.

파라핀 기반의 조직회수도구를 사용한 채취 조직의 진단 프로토콜 개발 (Development of Diagnosis Protocol for Micro-spike Biopsy Using Paraffin-based Tissue Collecting tool)

  • 정효영;구교인;이상민;박호수;홍석준;방승민;송시영;조동일
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.234-239
    • /
    • 2010
  • We have developed and reported several micro-spikes for minimally invasive biopsy. This paper presents a diagnosis protocol for micro-spike biopsy using paraffin-based tissue collecting tool. Using the proposed tissue collecting tool, which has a negative micro-spike structure in a porous chamber, the biopsied tissue in a micro-spike is effectively detached. The proposed diagnosis protocol prevents the loss of tissues in a paraffin embedding and sectioning process. Hence, it is compatible with conventional histopathology without additional reagents and processes. The gastro-intestinal tissue of a pig is biopsied in an in vivo environment, and then it is detached from a micro-spike using the paraffin-based tissue collecting tool. A histopathological photomicrograph of the detached tissue is acquired with the proposed diagnosis protocol. The acquired image offers clinical quality. This result shows that the paraffin-based tissue collecting tool is applicable to the medical practice.

균일 유동 마이크로 반응기의 설계와 검증 (Design and Evaluation of a Uniform Flow Microreactor)

  • 박지민;이승재;김경천
    • 한국가시화정보학회지
    • /
    • 제8권3호
    • /
    • pp.29-34
    • /
    • 2010
  • This paper proposes a design method to provide uniform flow in a microreactor. Uniform momentum approach is adopted with 10 pillars before and after the chamber having a different slope inlet channel. The slope and number of pillars are two factors to make a uniform flow in the microreactor, covering the hexagonal gold layer. The CFD analysis about the designed microreactor is carried out and the velocity vector field measurements are made in the fabricated microreactor by micro PIV technique. The uniformity of microreactor flow was confirmed by both numerical simulation and experimental results.

Dieletrophoresis를 이용한 초소형 세포융합시스템의 설계 및 해석 (Design and Analysis of the Microfabricated Cell Fusion System using Dielectrophoretic Force)

  • 양성동;이상욱;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.201-203
    • /
    • 1993
  • Recently, micro-scaled cell fusion system in the bioiogical cell fusion is preferred to Nacro-scaled one by dint of microelectronic processes. The microfabricated cell fusion system has its components such as fusion chamber, selector and detector. In this paper, we describe the design rules of the micro-fabricated cell fusion system using dielectrophoretic force and analyze its components using finite element method.

  • PDF

구동력과 가스 제공을 위한 이산화탄소 발생기 (Novel Micro Gas Generator of Carbon Dioxide for Actuation and Gas Source)

  • 최요한;손상욱;이승섭
    • 대한기계학회논문집A
    • /
    • 제29권7호
    • /
    • pp.970-975
    • /
    • 2005
  • This paper presents a novel microgenerator of $CO_2$ (carbon dioxide) gas. $NaHCO_3$ (sodium bicarbonate) in a chamber is decomposed by the underlaid microheater. Alternatively, water droplet is caged by paraffin layer and released by heating. The released water dissolve HOC(COOH)$(CH_2COOH)_2$ (citric acid) powder and then, $NaHCO_3$ reacts with the solubilized HOC(COOH)$(CH_2COOH)_2$ and $CO_2$ is produced. Micropumps actuated by $CO_2$ generation were fabricated. A portable micro cell incubator of which pH is controlled by the produced $CO_2$ is also presented as one of the further applications.

감광유리를 이용한 MEMS 촉매 연소기의 제작 및 성능 평가 (Fabrication and Performance Test of MEMS Catalytic Combustors Using Photosensitive Glass Wafer)

  • 진정근;권세진
    • 대한기계학회논문집A
    • /
    • 제33권3호
    • /
    • pp.237-242
    • /
    • 2009
  • MEMS catalytic combustors were fabricated to use in micro-power sources as a heat source. The combustor was fabricated by photolithography and anisotropic wet etching of photosensitive glass wafers. Two different catalyst loading methods were used to complete the fabrication of the combustors. For thin film type, the $Al_2O_3$ was washcoated on the surface of the combustion chamber as a catalyst support, and for packed-bed type, ceramic foam was inserted after Pt was coated. The volume of the combustors was 1.8 $cm^3$ and 16W of heat was generated using the fabricated combustors with hydrogen. The energy density of combustor was about 8.9 W/$cm^3$.

Effects of Ru Co-Sputtering on the Properties of Porous Ni Thin Films

  • Kim, Woo-Sik;Choi, Sun-Hee;Lee, Hae-Weon;Kim, Joo-Sun
    • 한국세라믹학회지
    • /
    • 제43권11호
    • /
    • pp.746-750
    • /
    • 2006
  • NiO films and Ru co-sputtered NiO films were deposited by reactive magnetron sputtering for micro-solid oxide fuel cell anode applications. The deposited films were reduced to form porous films. The reduction kinetics of the Ru doped NiO film was more sluggish than that of the NiO film, and the resulting microstructure of the former exhibited finer pore networks. The possibility of using the films for the anodes of single chamber micro-SOFCs was investigated using an air/fuel mixed environment. It was found that the abrupt increase in the resistance is suppressed in the Ru co-sputtered film, as compared to undoped film.