DOI QR코드

DOI QR Code

Development of Diagnosis Protocol for Micro-spike Biopsy Using Paraffin-based Tissue Collecting tool

파라핀 기반의 조직회수도구를 사용한 채취 조직의 진단 프로토콜 개발

  • Jeong, Hyo-Young (ASRI / ISRC, School of Electrical Engineering and Computer Sciences, Seoul National University) ;
  • Koo, Kyo-In (ASRI / ISRC, School of Electrical Engineering and Computer Sciences, Seoul National University) ;
  • Lee, Sang-Min (ASRI / ISRC, School of Electrical Engineering and Computer Sciences, Seoul National University) ;
  • Park, Ho-Soo (ASRI / ISRC, School of Electrical Engineering and Computer Sciences, Seoul National University) ;
  • Hong, Suk-Jun (ASRI / ISRC, School of Electrical Engineering and Computer Sciences, Seoul National University) ;
  • Bang, Seoung-Min (Department of Internal Medicine, College of Medicine, Yonsei University) ;
  • Song, Si-Young (Department of Internal Medicine, College of Medicine, Yonsei University) ;
  • Cho, Dong-Il (ASRI / ISRC, School of Electrical Engineering and Computer Sciences, Seoul National University)
  • 정효영 (서울대학교 공과대학 전기컴퓨터공학부 자동화시스템연구소 / 반도체연구소) ;
  • 구교인 (서울대학교 공과대학 전기컴퓨터공학부 자동화시스템연구소 / 반도체연구소) ;
  • 이상민 (서울대학교 공과대학 전기컴퓨터공학부 자동화시스템연구소 / 반도체연구소) ;
  • 박호수 (서울대학교 공과대학 전기컴퓨터공학부 자동화시스템연구소 / 반도체연구소) ;
  • 홍석준 (서울대학교 공과대학 전기컴퓨터공학부 자동화시스템연구소 / 반도체연구소) ;
  • 방승민 (연세대학교 의과대학 소화기내과) ;
  • 송시영 (연세대학교 의과대학 소화기내과) ;
  • 조동일 (서울대학교 공과대학 전기컴퓨터공학부 자동화시스템연구소 / 반도체연구소)
  • Received : 2009.11.18
  • Accepted : 2010.04.04
  • Published : 2010.06.30

Abstract

We have developed and reported several micro-spikes for minimally invasive biopsy. This paper presents a diagnosis protocol for micro-spike biopsy using paraffin-based tissue collecting tool. Using the proposed tissue collecting tool, which has a negative micro-spike structure in a porous chamber, the biopsied tissue in a micro-spike is effectively detached. The proposed diagnosis protocol prevents the loss of tissues in a paraffin embedding and sectioning process. Hence, it is compatible with conventional histopathology without additional reagents and processes. The gastro-intestinal tissue of a pig is biopsied in an in vivo environment, and then it is detached from a micro-spike using the paraffin-based tissue collecting tool. A histopathological photomicrograph of the detached tissue is acquired with the proposed diagnosis protocol. The acquired image offers clinical quality. This result shows that the paraffin-based tissue collecting tool is applicable to the medical practice.

Keywords

References

  1. Donald C. Zavola, "Diagnostic fiberoptic bronchoscopy: Techniques and results of biopsy in 600 patients," Chest, vol. 68, no. 1, pp. 12-19, 1975. https://doi.org/10.1378/chest.68.1.12
  2. K. L. Woods, B. S. Anand, R. A. Cole, M. S. Osato, Robert, M. Genta, H. Malaty, I. E. Gurer, and D. De Rossi, "Influence of endoscopic biopsy forceps characteristics on tissue specimens : results of a prospective randomized study," Gastrointestinal endoscopy, vol. 49, no. 2, pp. 177-183, 1999. https://doi.org/10.1016/S0016-5107(99)70483-9
  3. DD. Wadas, and R.A. Sanowski, "Complications of the hot biopsy forceps technique," Gastrointestinal endoscopy, vol. 34, no. 1, pp. 32-39, 1988. https://doi.org/10.1016/S0016-5107(88)71226-2
  4. A. R. Lee, S. J. Paik, K. I. Koo, S. G. Park, B. D. Choi, M. J. Jeong, H. M. Choi, J. M. Lim, J. M. Seo, K. A Kim, H. Chung, D. Y. Jeon, S. S. Lee, and D. I. Cho, "A Novel Microbiopsy Tool for Microsurgery," in Proc. of the Korean Sensors Society Conference, Cheju, Korea, Nov. 12-13, 2004, pp. 154-155.
  5. S. Byun, J. M. Lim, S. J. Palk, A. Lee, K. Koo, S. Park, J. Park, B. D. Choi, J. M. Seo, K. Kim, H. Chung, S. Y. Song, D. Jeon, and D. "Dan" Cho, "Barbed micro-spikes for micro-scale biopsy," J. Micromech. Microeng., vol. 15, no. 6, pp. 1279-1284, 2005. https://doi.org/10.1088/0960-1317/15/6/020
  6. A. R. Lee, S. J. Paik, S. G. Park, M. J. Jeong, K. I. Koo, H. M. Choi, J. M. Seo, K. A. Kim, H., Chung, S. Y. Song, S. M. Bang, D. Y. Jeon, J. M. Lim, and D. L Cho, "3D Silicon-micromachined Microbiopsy Tool and In-vivo Experiment," The 13th international Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Jun. 2005. pp. 1199-1202.
  7. S. K. Park, A. R, Lee, M. J. Jeong, H. M. Choi, S. Y. Song, S. M. Bang, S. J. Paik, J. M. Lim, D. Y. Jean, S. K. Lee, C N. Chu, and D. I. Cho, "A Disposable MEMS-Based Micro-Biopsy Catheter for the Minimally Invasive Tissue Sampling," IEEE/RSJ international Conference on Intelligent Robots and Systems, Alberta, Canada, Aug. 2005.
  8. G. S. Kim, S. K. Park, K l., Koo, H. M. Chai, M. J. Jung, S. Y. Song, S. M. Bang, and D. I. Cho, "Nickel Micro-spike for Micro-scale Biopsy Using LiGA Process," The 9th International Conference on Synchrotron Radiation Instrumentation, Daegu, Korea, May. 2006, pp. 1449-1502.
  9. G. S. Kim, S. Park, K. Koo, M. Jeong, H. Choi, S. Paik, S. M. Bang, S. Y. Song, and D. "Dan" Cho, "Micro spike for endoscopic gastro biopsy," Asia-Pacific Conference of Transducers and Micro-Nono Technology, Singapore, Singapore, Jun. 2006.
  10. H.Y. Jeong, K. I. Kyo, S. M. Lee, J. W.Ban, H. S. Park, S. M. Bang, S.Y. Song, and D. I. Cho, " Micro-tissue Collecting Tool for Diagnosis of Micro-spike Biopsy," Journal of the Korean Sensors Society, vol. 18, no. 2, pp. 122-127, 2009.
  11. S.I. Kim, Y.C. Shin, Y. S. Yang, G. Y Oh, Histopathology, Seoul, Daehakseorim, Press, 1995, pp. 41-48, pp. 155-164.
  12. Becker E. W., Ehrfeld W., Hagmann P., Maner A, and Munchmeyer D., "Fabrication of microstructures with high aspect ratios and great structural heights by synchrotron radiation lithography, galvanoforming, and plastic moulding (LIGA process)", Microelectronic Eng., vol.4, no. 1, pp. 35-56, 1986. https://doi.org/10.1016/0167-9317(86)90004-3