• 제목/요약/키워드: micro beads

검색결과 63건 처리시간 0.025초

Near-Field Detection of Aβ Proteins Using Micro Beads

  • Lee, Seung-Jun;Sung, Hee-Kyung;Choi, Yo-Han
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.319-323
    • /
    • 2012
  • In this paper, we present the possibility of quantification analysis for $A{\beta}$ captured by micro beads using Near-filed detection. In order to evaluate detection efficiency, detected signals were compared with different sizes of micro beads and a varied number of micro beads. Also, $A{\beta}$ deposits and $A{\beta}$ binding to micro beads were measured, therefore, we observed the $A{\beta}$ deposit and light scattering around the surface of micro beads induced by attached $A{\beta}$. This method can be used for quantitative analysis for not only the number of $A{\beta}$, but also the binding ratio of $A{\beta}$ to micro beads.

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channel and GMR-SV Device

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Khajidmaa, Purevdorj;Bolormaa, Munkhbat;Lee, Sang-Suk
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2015년도 임시총회 및 하계학술연구발표회
    • /
    • pp.161-163
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of RBC + ${\mu}Beads$ is controlled by the electrical AC input signal. The RBC + ${\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

  • PDF

A Micro Cell Counter Integrated with Oxygen Micropump

  • Son, Sang-Uk;Choi, Yo-Han;Lee, Seung-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2441-2444
    • /
    • 2003
  • This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and Sephadex G-25 beads counting experiment. The device utilized a phototransistor, microwindow, and light source of microscope for beads detection. Microheater and microchannel were used for pumping and guiding of beads to the microwindow. Counting capability of the device was tested with a peristaltic pump and the measured signals (${\sim}10\;mV$) with oscilloscope showed peak shape when beads passed the microwindow. Pumping of beads by the oxygen micropump was carried out by heating paraffin, which enveloped manganese dioxide (catalyst), to trigger the decomposition of hydrogen peroxide into water and oxygen. It lasted for 5 min with $7\;{\mu}l$ of wt. 30 % hydrogen peroxide. Beads counting by oxygen micropump showed peaks ($2{\sim}20\;mV$) with $30\;{\mu}l$ of beads sample and the number of peaks by magnitude was acquired.

  • PDF

3.0 T MRI 환경에서 마이크로비드를 이용한 서브복셀 추적에 관한 수치해석적 연구 (Numerical Study on the Sub-Voxel Tracking Using Micro-Beads in a 3.0 T MRI)

  • 한병희;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.102-107
    • /
    • 2007
  • In molecular imaging studies via magnetic resonance imaging, in vivo cell tracking is an important issue for the observation of cell therapy or disease behavior. High resolution imaging and longitudinal study are necessary to track the cell movement. Since the field inhomogeneity extends over several voxels, we have performed the numerical analysis using the sub-voxel method dividing a voxel of MR image into several elements and the information about the field inhomogeneity distribution around the micro-beads. We imbedded ferrite-composite micro-beads with the size of $20-150{\mu}m$ in the subject substituted for cells to induce local field distortion. In the phantom imaging with the isotropic voxel size of $200{\mu}m^3$, we could confirm the feasibility of sub-voxel tracking in a 3.0 T MRI.

Improved Immobilized Enzyme Systems Using Spherical Micro Silica Sol-Gel Enzyme Beads

  • Lee, Chang-Won;Yi, Song-Se;Kim, Ju-Han;Lee, Yoon-Sik;Kim, Byung-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권4호
    • /
    • pp.277-281
    • /
    • 2006
  • Spherical micro silica sol-gel immobilized enzyme beads were prepared in an emulsion system using cyclohexanone and Triton-X 114. The beads were used for the in situ immobilization of transaminase, trypsin, and lipase. Immobilization during the sol to gel phase transition was investigated to determine the effect of the emulsifying solvents, surfactants, and mixing process on the formation of spherical micro sol-gel enzyme beads and their catalytic activity. The different combinations of sol-gel precursors affected both activity and the stability of the enzymes, which suggests that each enzyme has a unique preference for the silica gel matrix dependent upon the characteristics of the precursors. The resulting enzyme-entrapped micronsized beads were characterized and utilized for several enzyme reaction cycles. These results indicated improved stability compared to the conventional crushed form silica sol-gel immobilized enzyme systems.

고대 유리구슬의 재질분석 연구-고성 내산리 출토 유리구슬을 중심으로 (The scientific analysis of glass beads excavated from Naesanri in Gosung)

  • 문환석;황진주;조남철;홍종욱
    • 보존과학연구
    • /
    • 통권21호
    • /
    • pp.57-75
    • /
    • 2000
  • We performed the scientific analysis through composition analysis, micro-structure investigation, melting point and hardness test to the glass beads excavated at Naesanri in Gosung. Through this investigation, we could examine closely the characterization of raw materials and manufacture technique As a result of micro-structure investigation of glass beads, it appeared that the bubbles in glass beads have remained. Coloring agents of yellow glass bead was remained to the shape of inclusion. And on observing the transparent solid particle, we can know that these do not melt the raw materials because of low melting temperature of a crucible. The result of composition analysis of all glass beads using ICP, these were classified as $Na_2O_2$-$SiO_2$ type of glass. Also, these added to $AI_2O_3$ to improve the durability. The value of Vickers hardness of glass beads appeared the HV 490-530. The HV 1,440 of the transparent solid particle was much more than that of inner glass bead. This means that raw materials do not melt because of a low melting temperature of a crucible. The result of melting temperature analysis of glass beads using DSC/TGA, it was measured about $1,250^{\circ}C$.

  • PDF

마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구 (Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device)

  • 박지수;김누리;정현준;이상석
    • 한국자기학회지
    • /
    • 제25권1호
    • /
    • pp.16-21
    • /
    • 2015
  • 광 리소그래피 공정을 이용하여 GMR-SV(Giant magnetoresistance-Spin valve) 다층박막 위에 마이크로 크기의 바이오센서용 소자와 코일-채널을 적층으로 각각 제작하였다. 직경 $1{\mu}m$ 크기인 여러 개의 자성비드가 결합된 적혈구가 마이크로 채널로 지나갈 때 코일에 인가하는 AC 신호로 정지 또는 통과하는 적혈구 움직임을 조절하였다. GMR-SV 소자 위에 포획된 적혈구-자성비드가 갖는 미세자기장은 자기저항비를 변화시켜 검출용 출력신호 특성으로 나타났다. 이것을 이용하여 자성비드를 결합한 적혈구의 막 변형에 따른 운동 특성을 분석하는 바이오센서로 활용할 수 있음을 보여주었다.

산소 미세 펌프가 내장된 미세 세포 계수기 (Micro Cell Counter Integrated with An Oxygen Micropump)

  • 손상욱;최요한;이승섭
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1159-1165
    • /
    • 2004
  • This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and counting experiment with Sephadex G-25 beads ($70{\sim}100\;{\mu}m$). The pumping part consisted of a microheater, catalyst (manganese dioxide) enveloped with paraffin, hydrogen peroxide, and microchannel, and the counting part consisted of collimated light, a microwindow, and a phototransistor including an external circuit. The micropump generated oxygen gas by decomposing hydrogen peroxide with manganese dioxide, which was initiated by melting the paraffin with the microheater, and pumped beads in the microchannel. When the beads passed the microwindow, they shaded the collimated light and changed the illumination on the phototransistor, which caused the current variation in the circuit. The signals, according to the bead size, reached up to 22 mV with noise level of 2 mV during 50 seconds and the numbers of peaks were analyzed by magnitude.

Micro Pre-concentration and Separation of Metal Ions Using Microchip Column Packed with Magnetic Particles Immobilized by Aminobenzyl Ethylenediaminetetraacetic Acid

  • Kim, Y.H.;Kim, G.Y.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권4호
    • /
    • pp.905-909
    • /
    • 2010
  • Magnetic beads (Dynabeads$^{(R)}$) embedded in ~1 micron size polystyrene beads bearing surface carboxylic acid groups were modified with aminobenzyl ethylenediaminetetraacetic acid (ABEDTA) to concentrate or separate metal ions using pH gradients on micro and nano scales. The immobilization of ABEDTA was achieved by amide formation. The presence of the metal chelating functional group in the fully deprotonated form was confirmed by FT-IR. The chelation efficiency of beads was tested by determining metal ions in supernatant using GFAAS when pH gradients from 3 to 7. Mixtures of Cu and Mg and of Cd and Mn (at 10 ng/mL of metal) were separated as the difference in formation constant with the functional group of ABEDTA. The separation was repeated twice with relative standard deviation of <18%. A polydimethylsiloxane (PDMS) microchip column packed with EDTA-coated magnetic beads was optimized to concentrate metal ion for practical applications by eluting a Cu solution of micro scale at pH 3.

Three Dimensionally Ordered Microstructure of Polycrystalline TiO2 Ceramics with Micro/meso Porosity

  • Chang, Myung Chul
    • 한국세라믹학회지
    • /
    • 제53권2호
    • /
    • pp.227-233
    • /
    • 2016
  • In order to make a highly ordered three-dimensional porous structure of titania ceramics, porogen beads of PS [Polystyrene] and PMMA [poly(methylmetacrylate)] were prepared by emulsion polymerization using styrene monomer and methyl methacrylate monomer, respectively. The uniform beads of PS or PMMA latex were closely packed by centrifugation as a porogen template for the infiltration of titanium butoxide solution. The mixed compound of PS or PMMA with titanium butoxide was dried and the dry compacts were calcined at $450^{\circ}C-750^{\circ}C$ according to the firing schedule to prepare micro- and meso- structures of polycrystalline titania with monodispersed porosity. Inorganic frameworks composed of $TiO_2$ were formed and showed a three Dimensionally Ordered Microstructure [3DOM] of $TiO_2$ ceramics. The pulverized particles of the $TiO_2$ ceramic skeleton were characterized using XRD analysis. A monodispersed crystalline micro-structure with micro/meso porosity was observed by FE-SEM with EDX analysis. The 3DOM $TiO_2$ skeleton showed opalescent color tuning according to the direction of light.