Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
Mass Spectrometry Letters
/
v.5
no.2
/
pp.42-48
/
2014
A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.
A simple LC-MS/MS method of rabeprazole in human plasma was developed and validated. Rabeprazole and Internal standard (I.S), omeprazole, were extracted from human plasma by liquid liquid extraction, chromatographic separation of rabaprazole in plasma was achieved at $45^{\circ}C$ with a Shiseido UG120 $C_{18}$ column and methanol-10 mM ammonium acetate buffer (pH 9.42 with ammonium water), as mobile phase. Rabeprazole produced a protonated precursor ion [$(M+H)^+$] at m/z 360.10 and corresponding product ion at m/z 242.21. Internal standard produced a protonated precursor ion [$(M+H)^+$] at 346.09 and corresponding product ion at m/z 198.09. This method showed linear response over the concentration range of $1{\sim}500\;ng/mL$ with correalation coefficient greater than 0.99. The lower limit of quantitation (LLOQ) using 0.2 mL plasma was 1 ng/mL, which was sensitive enough for pharmacokinetics studies. The method was specific and validated with a limit of quantitation of 1 ng/mL. The intra-day and inter-day precision and accuracy were acceptable for all samples including the LLOQ. The applicability of the method was demonstrated by analysis of plasma after administration of a single 10 mg dose to 36 healthy subject. From the plasma rabeprazole concentration versus time curves, the mean $AUC_t$ (The area under the plasma concentration-time curve from time 0 to 12 hr ) was $691.36{\pm}321.88\;ng{\cdot}hr/mL$, $C_{max}$ (maximum plasma drug concentration) of $353.21{\pm}131.52\;ng/mL$ reached $3.4{\pm}1.1\;hr$ after adiministration. The mean biological half-life of rabeprazole was $1.37{\pm}0.75\;hr$. Based on the results, this simple method could readily be used in pharmacokinetics studies.
The moment analysis of cyclic adenosine monophosphate (cAMP) was performed using chromatograms that were obtained with the pulse input method from an octadecyl silica (ODS) high-performance liquid chromatography (HPLC) column. The general rate (GR) model was employed to calculate the first absolute moment and the second central moment. Three important coefficients for moment analysis, which are molecular diffusivity ($D_m$), external mass transfer coefficient ($k_f$), and intra-particle diffusivity ($D_e$), were estimated by the Wilke-Chang equation, Wilson-Geankoplis equation, and comparing van Deemter equation to theoretical plate number equation, respectively. Experiments were conducted by various conditions of flow rates, methanol volume ratio of the mobile phase, and solute concentration. After the moment analysis, results were organized by van Deemter plots. Also van Deemter coefficients were compared each other to effect $H_{ax}$, $H_f$, and $H_d$ on height equivalent to a theoretical plate (HETP, $H_{total}$). The value of intraparticle diffusion ($H_d$) was the primary factor which makes for HETP whereas external mass transfer ($H_f$) was disregardable factor.
Kim, Boyoung;Lee, Joohee;Kim, Seonyeob;Lee, Eunji;Choi, Chorong;Kho, Younglim
Journal of Environmental Health Sciences
/
v.42
no.1
/
pp.53-60
/
2016
Objectives: Preservatives are commonly used in pharmaceuticals, cosmetics and other products to extend the expiration date and prevent the growth of microorganisms. Preservatives are generally effective in controlling mold and inhibiting yeast growth, and against a wide range of bacterial attacks as well. They also adversely affect the quality of sperm and cause precocious puberty in children. This study was performed to analyze seven preservatives used in pharmaceuticals and personal care products. Methods: Five kinds of pharmaceuticals and personal care products (PPCPs) were examined for analysis with a high performance liquid chromatography-diode array detector. Each sample was homogenized and the targeted compounds were extracted with methanol. The suspended particulate was removed by syringe filter. Next, the sample was injected into an HPLC system. The separation of the seven preservatives was achieved with a C18 column and gradient mode. The accuracies were between 73% and 120% and precision was lower than 11.58% (RSD). Results: All of the calibration curves showed good linearity with a coefficient of determination ($r^2$) over 0.999. Among the PPCP samples, the detection rate of preservatives was 32.5% for pharmaceuticals, 44.8% for toothpaste, 76.9% for mouthwash, 40.0% for body lotion and 56.0% for wet tissues. The average concentrations of the preservatives in PPCPs were BA 1141.0 mg/kg, MP 709.8 mg/kg, EP 624.9 mg/kg, PP 216.9 mg/kg, BP 167.8 mg/kg, and TCS 538.2 mg/kg. The most frequently detected preservatives in pharmaceuticals and personal care products were BA, MP and PP. The concentrations of preservatives exceeded Korean regulatory standards in 11 samples of medicines, three of mouthwash and two of body lotion. Conclusion: We found that most of the PPCP samples contained various preservatives. It is necessary to identify which preservatives were used and to determine the level of preservatives in PPCPs and to assess the health risk to susceptible populations such as children.
Isotope dilution mass spectrometry (ID-MS) based on liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed for the accurate determination of sorbic acid in tea-drink. An isotope analogue of sorbic acid, $^{13}C_2$-sorbic acid, was obtained by custom synthesis. MS was operated in the negative mode with selected reaction monitoring (SRM) mode of $[M-H]^-$${\rightarrow}$$[M-CO_2H]^-$ channel at m/z 111 ${\rightarrow}$ 67 for sorbic acid and at m/z 113 ${\rightarrow}$ 68 for its isotope analogue. Chromatographic separation was accomplished with a C18 column and an isocratic mobile phase of 55% of 50 mM ammonium acetate (pH 4.5) and 45% of methanol. Homogeneous reference materials were prepared for validation of this method, including repeatability and reproducibility tests, by fortifying tea-drink with sorbic acid in our laboratory. Repeatability and reproducibility studies showed that the ID-LC/MS method is a reliable and reproducible method which provides less than 3.8% of relative standard deviation (RSD) for the analysis of sorbic acid.
Kim, Il-Young;Du, Ok-Ju;Lee, Sung-Dck;Park, Young-He;Kim, Mi-Sun;Bea, Chung-Ho;Chae, Young-Zoo
Journal of Food Hygiene and Safety
/
v.25
no.2
/
pp.118-121
/
2010
A HPLC-MS/MS method was developed for simultaneous determination of six sweeteners (acesulfame-K, cyclamate, saccharin, sucralose, stevioside, aspartame) in children's favorite foods. The procedure involves an extraction of the six sweeteners with 50% methanol solution, sample clean-up using the Carrez clearing reagent and filtering with cartridge filter. The HPLC separation was performed on a Hypersil Gold (150 mm ${\times}$ 2.1 mm 5 um) column using the water/acetonitrile mobile phase (95:5). Mass spectrometric analysis was carried out using the TSQ Quantum Ultra operated in negative and positive ESI/SRM. With this method, good linear relationship, sensitivity and reproducibility were obtained. The spike recoveries of six sweeteners for 2 kinds of foods spiked into 0.4 mg/ kg ranged from 87.4 to 114.7%. The detection limits were above 0.02 mg/kg. The method has been applied to determination of six sweeteners in children's favorite foods.
Previous screening of the pharmacological action of Gastrodia elata (GE) root (Orchidaceae) showed that methanol (MeOH) extracts have significant anti-inflammatory properties. The antiinflammatory agents of GE, however, remain unclear. In this experiment, MeOH extracts of GE were fractionated with organic solvents for the anti-inflammatory activity-guided separation of GE. Eight phenolic compounds from the ether (EtOEt) and ethyl acetate (EtOAc) fractions were isolated by column chromatography: 4-hydroxybenzaldehyde (I), 4-hydroxybenzyl alcohol (II), benzyl alcohol (III), bis-(4-hydroxyphenyl) methane (IV), 4(4'-hydroxybenzyloxy)benzyl-methylether (V), 4-hydroxy-3-methoxybenzyl alcohol (VI), 4-hydroxy-3-methoxybenzaldehyde (VII), and 4-hydroxy-3-methoxybenzoic acid (VIII). To investigate the anti-inflammatory and anti-oxidant activity of these compounds, their effects on carrageenan-induced paw edema, arachidonic acid (AA)-induced ear edema and analgesic activity in acetic acid (HAc)-induced writhing response were carried out in vivo; cyclooxygenase (COX) activity, reactive oxygen species (ROS) generation in rat basophilic leukemia (RBL 2H3) cells and 1,1-diphenyl-2-picryl-hydroazyl (DPPH) scavenging activity were determined in vitro. These phenolic compounds not only had anti-inflammatory and analgesic properties in vivo, but also inhibited COX activity and silica-induced ROS generation in a dose-dependent manner. Among these phenolic compounds, compound VII was the most potent anti-inflammatory and analgesic. Compound VII significantly inhibited silica-induced ROS generation and compound VI significantly increased DPPH radical scavenging activity. Compounds I, II and III significantly inhibited the activity of COX-I and II. These results indicate that phenolic compounds of GE are anti-inflammatory, which may be related to inhibition of COX activity and to anti-oxidant activity. Consideration of the structure-activity relationship of the phenolic derivatives from GE on the anti-inflammatory action revealed that both C-4 hydroxy and C-3 methoxy radicals of benzyl aldehyde play an important role in anti-inflammatory activities.
Benzoic acid, methyl paraben, and butyl paraben are preservatives that have been used in pharmaceutical, cosmetic, and food products. However, as their toxicities for human have been reported, many nations and organizations including Korea have established a regulation limit for thier usage of these preservatives in food products. The present study developed the isotope dilution liquid chromatography mass spectrometry method for accurate determination of three target preseratives in soysauce. In this study, the isotope dilution liquid chromatography mass spectrometry method was developed for accurate determination of three target preservatives in soy sauce. LC separation was optimized considering the pKa of benzoic acid which is lower than those of methyl and butyl parabens. A C18 column was used with 5 mM ammonium acetate and methanol as mobile phases. Mass spectrometry was operated in negative mode and selected reaction monitoring mode (SRM). Soy sauce sample was cleaned-up with C18 SPE cartridge for removing matrix inferences and color material. Optimized conditions and the method were validated with soy sauce reference materials for the analysis of food preservatives from Health Science Authority in Singapore. The measured values of benzoic acid, methyl and butyl paraben agreed well with reference values within their uncertainties.
The objective of this research is to present method development and validation for the simultaneous determination of lutein and zeaxanthin using ultra performance liquid chromatography (UPLC). Also, rapid quantification was performed on six green leafy vegetables (Allium tuberosum, Aster scaber, Hemerocallis fulva, Pimpinella brachycarpa, Sedum sarmentosum and Spinacia oleracea) that are commonly consumed in Korea. Separation and quantification were successfully achieved with a Waters Acquity BEH C18 ($50{\times}2.1mm$, $1.7{\mu}m$) column by 85% methanol within 5 min. Two compounds showed good linearity ($r^2$ > 0.9968) in $1-150{\mu}g/mL$. Limit of detection (LOD) and quantification (LOQ) for lutein and zeaxanthin were 1.7 and 5.1 g/mL and 2.1 and 6.3 g/mL, respectively. The RSD for intra- and inter-day precision of each compound was less than 10.69%. The recovery of each compound was in the range of 91.75-105.13%. Aster scaber and Spinacia oleracea contained significantly higher amounts of lutein ($4.06{\pm}0.24$ and $3.97{\pm}0.10mg$/100 g of fresh weight), respectively.
Chung, Hyung Suk;Lee, Young Jun;Lee, Han Sol;Rahman, Md. Musfiqur;Kabir, Md. Humayun;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
Korean Journal of Environmental Agriculture
/
v.36
no.3
/
pp.201-210
/
2017
BACKGROUND: The current study was to monitor of 9 veterinary antibiotics (ceftiofur, clopidol, florfenicol, sulfamethazine, sulfamethoxazole, sulfathiazole, tetracycline, tiamulin, and tylosin) in manure using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive and negative electrospray ionization mode. METHODS AND RESULTS: Sample preparation was carried out using Mcllvaine buffer and citrate salts to adjust the pH of the sample followed by purification with dispersive solid phase extraction (d-SPE). Separation of analytes during LC-MS/MS analysis was conducted using an Eclipse Plus $C_{18}$ column and the mobile phase was in gradient mode with, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations of all tested antibiotics was good, with $R^2$ determination coefficients ${\geq}0.9920$. The limit of detection (LOD) and quantifications (LOQ) were $0.1-67.0{\mu}g/kg$ and $0.4-200.0{\mu}g/kg$, respectively. Analysis of 13 solid and liquid manure samples taken from the Republic of Korea revealed concentrations less than $0.7{\mu}g/kg$ for tiamulin, $1497.6{\mu}g/kg$ for sulfamethazine. CONCLUSION: To monitor 9 veterinary antibiotics from manure samples in 13 provincial areas throughout the Republic of Korea, an analytical method was developed. The developed method was fully validated and successfully applied for monitoring various veterinary antibiotics in manure samples.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.