• Title/Summary/Keyword: metallic contamination

Search Result 57, Processing Time 0.027 seconds

중금속 오염이 n형 실리콘 태양전지의 전기적 특성에 미치는 영향에 대한 연구 (Influence of Metallic Contamination on Photovoltaic Characteristics of n-type Silicon Solar-cells)

  • 김일환;박준성;박재근
    • Current Photovoltaic Research
    • /
    • 제6권1호
    • /
    • pp.17-20
    • /
    • 2018
  • The dependency of the photovoltaic performance of p-/n-type silicon solar-cells on the metallic contaminant type (Fe, Cu, and Ni) and concentration was investigated. The minority-carrier recombination lifetime was degraded with increasing metallic contaminant concentration, however, the degradation sensitivity of recombination lifetime was lower at n-type than p-type silicon wafer, which means n-type silicon wafer have an immunity to the effect of metallic contamination. This is because heavy metal ions with positive charge have a much larger capture cross section of electron than hole, so that reaction with electrons occurs much more easily. The power conversion efficiency of n-type solar-cells was degraded by 9.73% when metallic impurities were introduced in the silicon bulk, which is lower degradation compared to p-type solar-cells (15.61% of efficiency degradation). Therefore, n-type silicon solar-cells have a potential to achieve high efficiency of the solar-cell in the future with a merit of immunity against metal contamination.

폐광산 인근 농경지 및 하천 퇴적토의 중금속 오염 특성 (Distribution of Metallic Elements Contamination in River Deposits and Farmland in the Vicinity of an Abandoned Korean Mine)

  • 이환;이윤진
    • 자원환경지질
    • /
    • 제53권2호
    • /
    • pp.133-145
    • /
    • 2020
  • 본 연구는 대한민국 충청도에 위치한 폐광산을 대상으로 오염경로를 분석하기 위해 갱구, 하천 퇴적토 및 인근 농경지의 중금속 오염 확산 특성을 조사하였다. 연구대상지역에서 갱내수 유출지점으로부터 약 61 m까지 적화현상이 관찰되었고 총 1800 ㎥의 폐석 유실구간이 확인하였다. 갱내수는 우기기간동안 pH 4.9, 황산염의 농도 1557.8 mg/L를 나타냈다. 동일한 기간에 황산염 농도는 하천시료에서 평균 773.6 mg/L으로 나타났다. 하천에서 채취한 황갈색 시료를 분석한 결과 침철석과 페리하이드라이트(ferrihydrite)로 나타났다. 본 연구지역의 주요 오염원은 폐석 손실에 의한 것으로 여겨지며 토양오염우려기준을 초과한 오염 필지는 총 10,297 ㎡로 산정되었다.

동위원소를 이용한 폐금속광산 지역 오염원 추적 연구

  • 염승준;이평구;이인경;이욱종
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.209-212
    • /
    • 2006
  • Using sulfur sotope analysis of dissolved sulfate in surface water, we have investigated the source of sulfate in order to identify the abandoned metallic mines, which have the potential of heavy metal contamination within watershed. The range of the sulfur isotope values for dissolved sulfate in stream waters (DD-1 and 2) are similar to those of sulfides from the Dunjun mine, which suggests that oxidation of sulfides is the principal source of $SO_4^{2-}$ in these stream waters. Also, heavier sulfur isotopes in waters near Baekjun and Hamchang mines imply the possibility of contamination in waters by these metallic mines.

  • PDF

추출방법에 따른 금속광산 주변의 토양오염 특성 (Soil Pollution Characteristics of Metallic Mine Area according to Extraction Methods)

  • 양중석;이주영;박영태;백기태;최재영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권3호
    • /
    • pp.1-6
    • /
    • 2010
  • This study investigated the change of metal contamination levels according to amendment of enforcement regulation of the Soil Environmental Conservation Act in Korea. As an analytical result of 87 samples in abandoned metallic mine area, the extracted amount of As, Pb and Cu with aqua regia was 4.3~29.6 times higher than that with hydrochloric acid extraction and the number of samples, which contamination levels were found to exceed soil contamination standards, was also increased. On the other hand, in case of Cd, Zn, and Ni, the number of samples, which contamination levels were found to exceed soil contamination standards, was decreased or similar. These results can be used as a preliminary material in comparison between the soil pollution data accumulated previously and the data obtained by the revised standard method for the examination of soil pollution.

화순천의 퇴적환경 및 퇴적물과 하천수의 지구화학적 특성 (Sedimentary Environments, Geochemical Characteristics of Sediments and River waters, Hwasun-cheon)

  • 오강호;고영구;김주용;김해경
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.881-895
    • /
    • 2002
  • Sediments and river waters form the channel of Hwasun-cheon were studied in sedimentological size and geochemical analyses of metallic elements for the purposes of identification of depositional environments and geochemical characteristics. The sizes of sediments are assigned to pebble to coarse sand in mean size and polymodal in distribution. And the sediments are poorly to very poorly sorted and positively skewed. According to the grain size distributions of the sediments, the Hwasun-cheon belongs to gravel-bed river on the basis of the grain size distribution of the sediments. The behaviors of metallic elements in the sediments mainly depend on not grain size distribution but the geology connected with geomorphological reliefs near the stream. Contamination indices(CI) of Zn, Cu and Pb are 2.83 to 6.96 with average 4.31 in the sediments. Hwasun-cheon is assigned to general stream type in accordance with water quality of physical factors and chemical characteristics by Piper's diagram. Though meaningful values of BOD, T-N, T-P were locally depicted near Masan-ri, Hwasun-eup and Jiseok-cheon areas, artificial metal concentration do not represent in the most area of the stream. Sediments and river water are considered that the relatively more or less high metallic contents in the stream are originated from coal mine and urban area.

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

CHARACTERIZATION OF METALLIC CONTAMINATION OF SILICON WAFER SURFACES FOR 1G DRAM USING SYNCHROTRON ACCELERATOR

  • Kim, Heung-Rak;Kun-Kul, Ryoo
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.239-243
    • /
    • 1999
  • At Present, 200mm wafer technology is being applied for commercial fabrications of 64, 128, and 256 M DRAM devices, and 300mm technology will be evolved for 1G DRAM devices in the early 21th century, recognizing limitations of several process technologies. In particular recognition has been realized in harmful effects of surface contamination of trace metals introduced during devicing processes. Such a guide line for surface metal contamination has been proposed as 1E9 and 1E10 atoms/$\textrm{cm}^2$ of individual metal contamination for wafering and devicing of 1G DRAM, respectively, and so its measurement limit should be at least 1E8 atoms/$\textrm{cm}^2$. The detection limit of present measurement systems is 2E9 atoms/$\textrm{cm}^2$ obtainable with TRXFA(Total Reflection X-Ray Fluorescence Analysis). TRXFA is nondestructive and the simplest in terms of operation, and it maps the whole wafer surfaces but needs detection improvement. X-Ray intensity produced with synchrotron accelerator is much higher than that of conventional X-ray sources by order of 4-5 magnitudes. Hence theoretically its reactivity with silicon surfaces is expected to be much higher than the conventional one, realizing improvement of detection limit. X-ray produced with synchrotron accelerator is illuminated at a very low angle with silicon wafer surfaces such as 0.1 degree and reflects totally. Hence informations only from surface can be collected and utilized without overlapping with bulk informations. This study shows the total reflection phenomenon and quantitative improvement of detection limit for metallic contamination. It is confirmed that synchrotron X-ray can be a very promising alternative for realizing improvement of detection limit for the next generation devices.

  • PDF

금속 불순물 Ca이 Si 기판의 표면 미세 거칠기에 미치는 영향 (The Effect on the Microroughness of Si Substrate by Metallic Impurity Ca)

  • 최형석;전형탁
    • 한국재료학회지
    • /
    • 제9권5호
    • /
    • pp.491-495
    • /
    • 1999
  • In this study, we focus on Ca contaminant which affects on the roughness Si substrate after thermal process. The initial Si substrates were contaminated intentionally by using a standard Ca solution. The contamination levels of Ca impurity were measured by TXRF and the chemical composition of that was analyzed by AES. Then we gre the thermal oxide to investigate the effect of Ca contaminants. The microroughness of the Si surface, the thermal oxide surface, and the surface after removing the thermal oxide were measured to examine the electrical characteristics. The initial substrates that were contaminated with the standard solution of Ca exhibited the contamination levels of 10\ulcorner~10\ulcorneratoms/$\textrm{cm}^2$ which was measured by TXRF. The Ca contaminants were detected by AES and exhibited the peaks of Ca, SI, C and O.After intentional contamination, the surface microroughness of this initial substrate was increased from $1.5\AA$ to 4$\AA$ as contamination levels became higher. The microroughness of the thermal oxide surfaces of both contaminated and bare Si substrates exhibits similar values. But the microroughness of the contaminated$ Si/SiO_2$ interface was increased as contamination increased. The thermal oxide of contaminated substrate exhibited the small minority carrier diffusion length, low breakdown voltage, and slightly high leakage current.

  • PDF

Exploration of Metallic Contamination in Fish Species of the Polluted Rivers in Bangladesh

  • Rahman, Mokhlesur;Jiku, Abu Sayem;Alim, Abdul;Kim, Jang-Eok
    • Journal of Applied Biological Chemistry
    • /
    • 제57권2호
    • /
    • pp.131-136
    • /
    • 2014
  • An attempt was made to assess metal ionic toxicity levels of different fishes in the polluted rivers viz., Buriganga and Turag. Fish samples collected from two polluted rivers were analyzed for the levels of metals such as Cd, Cr, Cu, Mn, Pb, and Zn in order to elucidate the status of these contaminants in fish meant for human consumption. The detected concentrations of Cr, Cu, Mn, and Zn ions in fish species collected from the polluted rivers were below the toxic levels and did not appear to pose a threat. Among the analyzed metals, Cd and Pb ions were detected above the permissible levels in liver and muscle tissues of stinging catfish (Heteropneustesfossilis), spotted snakehead (Channapunctata) and wallago (Wallagoattu) collected from the polluted rivers causing toxicity for human consumption. Stinging catfish (Heteropneustesfossilis) was the species found to highly bioaccumulate these metals. Fish species bioconcentrated appreciable amounts of Cd and Pb as toxic metals in the liver as compared to the muscle. Levels of these toxic metals varied depending on different tissues in fish species.

High-$T_c$ SQUID Application for Roll to Roll Metallic Contaminant Detector

  • Tanaka, S.;Kitamura, Y.;Uchida, Y.;Hatsukade, Y.;Ohtani, T.;Suzuki, S.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.82-86
    • /
    • 2012
  • A sensitive eight-channel high-Tc Superconducting Interference Device (SQUID) detection system for magnetic contaminant in a lithium ion battery anode was developed. Finding ultra-small metallic foreign matter is an important issue for a manufacturer because metallic contaminants carry the risk of an internal short. When contamination occurs, the manufacturer of the product suffers a great loss from recalling the tainted product. Metallic particles with outer dimensions smaller than 100 microns cannot be detected using a conventional X-ray imaging system. Therefore, a highly sensitive detection system for small foreign matter is required. We have already developed a detection system based on a single-channel SQUID gradiometer and horizontal magnetization. For practical use, the detection width of the system should be increased to at least 65 mm by employing multiple sensors. In this paper, we present an 8-ch high-Tc SQUID roll-to-roll system for inspecting a lithium-ion battery anode with a width of 65 mm. A special microscopic type of a cryostat was developed upon which eight SQUID gradiometers were mounted. As a result, small iron particles of 35 microns on a real lithium-ion battery anode with a width of 70 mm were successfully detected. This system is practical for the detection of contaminants in a lithium ion battery anode sheet.