Compact Cascaded Quadruplet Bandpass Filter Using Modified Coaxial Cavity Resonator with Q-Factor Improvement (품질계수가 향상된 변형된 동축 공동 공진기를 이용한 다단 Quadruplet 대역통과 여파기)

  • Jang, Geon-Ho;Wang, Xu-Guang;Lee, Bo-Ram;Park, Nam-Shin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.966-977
    • /
    • 2015
  • This paper presents a novel modified coaxial cavity resonator and its application to bandpass filters with compact size and improved quality factor(Q-factor). The proposed resonator is made up of ${\Gamma}-shape$ or curved four inner conductive posts within a single cavity, which provides quadruplet to realize bandpass filter. No metallic walls inside the cavity are required, and thus the utilization efficiency of the cavity space is improved. As a result, the unloaded Q can be approximately 15 % higher in comparison to the conventional coaxial resonator, or more than 35 % volume saving can be achieved while maintaining the similar Q-factor value with the conventional designs. In addition, due to the multiple cross-coupling occurring within the cavity, including the source-to-load coupling, four flexible transmission zeros can be created to realize different filtering functions. Simulations as well as experimental results of four- and eight-pole filters are presented to validate this attractive design concept. Good agreement between measured and computed results is obtained.

Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2014
  • Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

Antenna sensor skin for fatigue crack detection and monitoring

  • Deshmukh, Srikar;Xu, Xiang;Mohammad, Irshad;Huang, Haiying
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.93-105
    • /
    • 2011
  • This paper presents a flexible low-profile antenna sensor for fatigue crack detection and monitoring. The sensor was inspired by the sense of pain in bio-systems as a protection mechanism. Because the antenna sensor does not need wiring for power supply or data transmission, it is an ideal candidate as sensing elements for the implementation of engineering sensor skins with a dense sensor distribution. Based on the principle of microstrip patch antenna, the antenna sensor is essentially an electromagnetic cavity that radiates at certain resonant frequencies. By implementing a metallic structure as the ground plane of the antenna sensor, crack development in the metallic structure due to fatigue loading can be detected from the resonant frequency shift of the antenna sensor. A monostatic microwave radar system was developed to interrogate the antenna sensor remotely. Fabrication and characterization of the antenna sensor for crack monitoring as well as the implementation of the remote interrogation system are presented.

Evaluation on Liquid Formability of Bulk Amorphous Alloys (벌크비정질합금의 액상 성형성 평가)

  • Joo, Hye-Sook;Kang, Bok-Hyun;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.26 no.5
    • /
    • pp.227-231
    • /
    • 2006
  • Liquid formability of bulk amorphous alloys is known to be very poor due to their high viscosity comparing with conventional metallic materials. It is important to have the fabricating technology of bulk amorphous alloys in order to make the components with complicated shape. Liquid formability includes the mold cavity filling ability and the hot tear(crack) resistance during solidification. A mold made of a commercial tool steel for the formability test was designed. Melting was performed by the arc melting furnace with melting capacity of 200 g in an argon atmosphere. Liquid formability and glass forming ability of Cu base and Ni base bulk amorphous alloys were measured and evaluated. Mold filling ability of Ni-Zr-Ti-Si-Sn alloy was better than that of Cu-Ni-Zr-Ti alloy, however the reverse is the hot tear resistance. Bulk amorphous alloy is very susceptible to crack if partial crystallization occurs during solidification. Crack resistance was thought to be closely related with the glass forming ability.

A Self-Oscillation Type SAW Microgyroscope Based on the Coriolis Effect of Progressive Waves (진행파의 코리올리효과를 이용한 자가발진형 표면탄성파 초소형 자이로스코프)

  • Oh, Hae-Kwan;Choi, Ki-Sun;Lee, Hyung-Keun;Lee, Kee-Keun;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.390-396
    • /
    • 2010
  • An 80MHz surface acoustic wave (SAW)-based gyroscope utilizing a progressive wave was developed on a piezoelectric substrate. The developed sensor consists of two SAW oscillators in which one is used for sensing element and has metallic dots in the cavity between input and output IDTs. The other is used for a reference element. Coupling of mode (COM) modeling was conducted to determine the optimal device parameters prior to fabrication. According to the simulation results, the device was fabricated and then measured on a rate table. When the device was subjected to an angular rotation, oscillation frequency differences between the two oscillators were observed because of the Coriolis force acting on the metallic dots. Depending on the angular rate, the difference of the oscillation frequency was modulated. The obtained sensitivity was approximately 52.35 Hz/deg.s within the angular rate range of 0~1000 deg/s. The performances of devices with three IDT structures for two kinds of piezoelectric substrates were characterized. Good thermal stability was also observed during the evaluation process.

40 GHz Vertical Transition with a Dual-Mode Cavity for a Low-Temperature Co-fired Ceramic Transceiver Module

  • Byun, Woo-Jin;Kim, Bong-Su;Kim, Kwang-Seon;Eun, Ki-Chan;Song, Myung-Sun;Kulke, Reinhard;Kersten, Olaf;Mollenbeck, Gregor;Rittweger, Matthias
    • ETRI Journal
    • /
    • v.32 no.2
    • /
    • pp.195-203
    • /
    • 2010
  • A new vertical transition between a substrate integrated waveguide in a low-temperature co-fired ceramic substrate and an air-filled standard waveguide is proposed in this paper. A rectangular cavity resonator with closely spaced metallic vias is designed to connect the substrate integrated waveguide to the standard air-filled waveguide. Physical characteristics of an air-filled WR-22 to WR-22 transition are compared with those of the proposed transition. Simulation and experiment demonstrate that the proposed transition shows a -1.3 dB insertion loss and 6.2 GHz bandwidth with a 10 dB return loss for the back-to-back module. A 40 GHz low-temperature co-fired ceramic module with the proposed vertical transition is also implemented. The implemented module is very compact, measuring 57 mm ${\times}$ 28 mm ${\times}$ 3.3 mm.

Reduction Characteristics of Electromagnetic Fields in Cavity by Lossy Dielectric Materials (손실 유전체를 이용한 공동 내부의 전자계 저감 특성)

  • 정광현;김기채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.950-954
    • /
    • 2003
  • This paper presents the delivered power and reflection coefficient in metallic shielding enclosure excited by the interior source, which are evaluated with the method of moments, and describes a method for reducing the radiation of electromagnetic fields in the cavity by putting lossy dielectric material in one inside wall. In this paper we introduce carbon polystyrene-foam as lossy dielectric material and observe it's effects of reduction when the thickness and permittivity of lossy dielectric material are changed. The results show that the reduction of the electromagnetic radiation can be achieved by controlling the amount of carbon in lossy dielectric material. The theoretical analysis is verified by the measured delivered power.

Thin Micro-Porous Scaffold Layer on Metallic Substrate (금속기질에 앓은 마이크로 다공질 스케폴드 코팅에 관한 연구)

  • Sin, D.C.;Miao, X.;Kim, W.C.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.41-47
    • /
    • 2010
  • 티타늄과 티타늄 합금은 재료적 특이성 때문에 심장 혈관 임플란트에서 일반적으로 사용되어 왔다. 일찍이 적용된 예로는 인공심장판막, 심박조율기의 보호케이스, 혈액 순환 장치 등이 있다. 하지만 물질유도혈전증(Material-induced thrombosis)은 혈전폐색에 의해 기인한 기능 손실로 심장혈관 임플란트 장치의 주된 합병증으로 존재하고 있으며, 심장혈관 임플란트의 혈전유전자는 심장혈관장치의 발달에 주된 난관 중 하나로 남아있다. 그리고 텍스처 혈액 접합 물질(Textured blood-contacting material)은 1960년대 초반 이후부터 혈액순환 보조 장치의 임상실험에 사용되고 있다. 접합 물질에 내장된 텍스처 섬유조직 표면은 형성, 성장, 안정적 부착, 생물학적 내벽(neointimal layer) 등 유도 혈액(entrapping blood) 성분에 의해 형성된다. 공동(cavity) 형상의 용해 가능한 미립자를 사용하는 SCPL법(Solvent casting/particulate leaching method)은 티타늄 기질 이전에 형성된 폴리우레탄 위에 텍스처(texture)를 생성하기 위해 사용되었다. 또한 콜라겐의 부동화(不動化)에 의한 공동(cavity)은 혈액 접합면에 잔존하기 위한 내피세포를 고정할 수 있는 효과가 있다. cpTi로 층화된 PU 기소공성(microporous)은 구조적 특성과 혈전증 감소를 위한 생물학적 내벽 사용의 잠재성을 평가하기 위한 세포 공동체 실험을 통해서 평가되었다.

A HIGH-RESOLUTION NUMERICAL ANALYSIS OF SHOCK FOCUSING IN CONCAVE REFLECTORS (반사경 내부 유동의 초점 형성에 관한 고해상도 수치 해석)

  • Jung, Y.G.;Chang, K.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.170-175
    • /
    • 2009
  • Shock focusing is related with explosive release of shock wave energy on a narrow spot in a short duration of time triggering a spontaneous high pressure near the focal point. It is well known that reflection of planar incident shock wave from the metallic concave mirror such as ellipsoidal, paraboloidal or hemispherical cavities will focus on a focal point. We intend to improve the computational results using a wave propagation algorithm and to resolve the mushroom-like structure. For computation of the concave cavity flow, it is not easy to use a single-block mesh because of the many singular points in geometry and coordinates. We have employed a uniform Cartesian-grid method for the wave propagation algorithm.

  • PDF

Coupling characteristics of localized modes of line defects in two-dimensional photonic crystals (2차원 광자결정 도파로에서 결함모드의 결합특성)

  • Cho, Dae-Hee;Park, Hye-Young;Kee, Chul-Sik;Lim, H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.270-272
    • /
    • 2003
  • We have investigated the coupling characteristics of localized modes of line defect i.e., guided modes, in photonic crystals. The parity of the coupled guided modes is not conserved when the distance between the line defects changes. By comparing the coupling characteristics of localized modes without the oscillatory nature such as cavity modes of metallic Fabry-Parot cavities with those of localized modes in photonic crystals, we confirmed that this parity nonconservation is attributed to the oscillatory nature of the evanescent waves of localized modes in photonic crystals.

  • PDF