• 제목/요약/키워드: metal insulation

검색결과 154건 처리시간 0.027초

금속단열재 박판의 설계인자별 단열성능 영향 연구 (Studies on Insulation Effect Related with Thin-Plate Design Factors for Reflective Metal Insulation(RMI) of Nuclear Power Plant)

  • 어민훈;이성명;장계환
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.350-354
    • /
    • 2016
  • Although fibrous insulations are generally used with resistive insulation type, metallic insulation is proper matter to satisfy low head-loss and equipment life when considering the specific condition, especially for Nuclear power plant. Common insulation is resistance insulation with a low thermal conductivity. but RMI is made of sheet plate with low emissivity and closed air space. Thermal radiation is blocked by stainless steel with low emissivity. Thermal conductivity and thermal convection are blocked by closed air space. This study shows the changes and effects of the heat loss according to shape and method of stacking sheet plates inserted into the insulation and analyzed the most optimized way for thermal insulation performance. The result shows that using sheet plate structure through raised and protruding shape processing was the appropriate model to optimize thermal performance. Additionally, insulating performance of RMI improved by placing the sheet plate in a high temperature region intensively.

원전 금속단열재의 구조 건전성 강화를 위한 설계 방안 (Design for Strengthening Structural Integrity of the Reflective Metal Insulation in the Nuclear Power Plant)

  • 이성명;어민훈;김승현;장계환
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.107-113
    • /
    • 2015
  • The goal of this paper is to investigate structural integrity factors of RMI(reflective metal insulation) to confirm the design requirements in nuclear power plant. Currently, a glass wool insulation is using now, but it will gradually be replaced with the reflective metal insulation maded by stainless steel plates. The main function of an insulation is to minimize a heat loss of vessel and pipes in RCS(reactor coolant system). It has to maintain structural a integrity in nuclear power plant life duration. In this study, the structural integrity analysis was carried out both multi-plate and outer shell plate by using a static analysis and experimental test. First, inner multi-plate has a self support structure for being air space. Because the effect of total static weight in multi-layer plate is low, a plate collapse possibility is not high. Considering optimum thin plate pressing process, it has to pre-check the basic physical properties. Second, the outer segment thickness and stiffener shape are verified by the numerical static analysis, and sample test for both type of panel and cylindrical pipe model.

알루미늄 용탕 운반용 고보온성 Ladle 설계 및 평가 (Design and Evaluation of High Insulation Ladle for Carrying Aluminum Molten Metal)

  • 박진영;최석환;윤필환;김억수
    • 한국주조공학회지
    • /
    • 제30권3호
    • /
    • pp.115-120
    • /
    • 2010
  • Recently, an advanced raw material supplying system in diecasting industry that molten metal produced by the raw material supplier can be directly delivered to the diecasting shops was proposed. It was known to have advantages of reducing melting process cost and improving working environment. However, for its successful mass production, the development of high insulation ladle is inevitable. In this study, the optimal mixing ratio of $SiO_2-Al_2O_3$ was investigated and the high insulation ladle with computer simulation result was built in a prototype and evaluated. The prototype which has refractory wall of $SiO_233%-Al_2O_3$ 35%-CaO 33% showed high insulation sufficient for carrying the Al molten metal for 138 minutes. Gas quantity result and SEM-EDS analysis on the melt poured in the ladle also showed extremely low level of 0.028 cc / 100 g and no penetration of Al molten metal into the refractory wall, satisfying the requirements for mass production.

유기박막 트랜지스터용 PVP (poly-4-vinylphenol) 게이트 절연막의 제작과 특성 (Preparation and Properties of PVP (poly-4-vinylphenol) Gate Insulation Film For Organic Thin Film Transistor)

  • 백인재;유재헉;임현승;장호정;박형호
    • 마이크로전자및패키징학회지
    • /
    • 제12권4호통권37호
    • /
    • pp.359-363
    • /
    • 2005
  • 유기 박막트랜지스터 (OTFT)를 제작하기 위하여 게이트 절연막으로서 PVP 계통의 유기막을 갖는 MIM(metal-insulator-metal)구조의 유기 절연층 소자를 제작하였다. 유기 절연층의 형은 ITO/Glass 기판위에 polyvinyl 계열의 PVP(poly-4-vinylphenol)를 용질로, PGMEA (propylene glycol monomethyl ether acetate)를 용매로 사용하여 co-polymer PVP를 제조하였다. 또한 열경화성 수지인 poly(melamine-co-formaldehyde)를 경화제로 사용하여 cross-linked PVP 절연막을 합성하였다. 유기 절연층의 전기적 특성은 co-polymer PVP 소자에 비해 cross-link 방식으로 제조된 소자에서 약 300 pA의 낮은 누설전류와 상대적으로 낮은 잡음전류의 특성을 나타내었다. 또한 cross-linked PVP 절연막에서 보다 양호한 표면형상 (거칠기)이 관찰되었으며 정전용량 값은 약 0.11${\~}$0.18 nF의 값을 나타내었다.

  • PDF

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.

Contact resistance characteristics of 2G HTS coils with metal insulation

  • Sohn, M.H.;Ha, H.;Kim, S.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.26-30
    • /
    • 2018
  • The turn-to-turn contact resistance of 2G high temperature superconducting (HTS) coils with metal insulation (MI) is closely related to the stability of the coils, current charging rate and delay time [1]. MI coils were fabricated using five kinds of metal tapes such as aluminum (Al) tape, brass tape, stainless steel (SS) tape, copper (Cu)-plated tape and one-sided Cu-plated SS tape. The turn-to-turn contact surface resistances of co-winding model coils using Al tape, brass tape, and SS tape were 342.6, 343.6 and $724.8{\mu}{\Omega}{\cdot}cm^2$, respectively. The turn-to-turn contact resistance of the model coil using the one-sided Cu-plated SS tape was $ 248.8{\mu}{\Omega}{\cdot}cm^2$, which was lower than that of Al and brass tape. Al or brass tape can be used to reduce contact resistance and improve the stability of the coil. Considering strength, SS tape is recommended. For strength and low contact resistance, SS tape with copper plating on one side can be used.

트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가 (Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame)

  • 송진희;이동윤;신동일;전현도;박철용;김상균
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

금속진공단열패널의 심재용 기포콘크리트의 성능에 관한 연구 (A Study on the Performance of Foamed Concrete for Cores Material of Metal Vacuum Insulation Panel)

  • 홍상훈;김봉주
    • 한국건축시공학회지
    • /
    • 제20권5호
    • /
    • pp.417-423
    • /
    • 2020
  • 건축물의 에너지 소비 중 40%인 냉·난방을 줄이기 위해 외피 단열향상이 중요시되고 있다. 이에 기존 단열재를 개선하기 위해 진공단열패널VIP(Vacuum Insulation Panel)을 건축물에 적용하기 위한 연구가 진행되고 있다. 하지만 VIP는 보수보강이 불가능해 이를 개선한 금속진공단열패널을 고려하였다. 금속진공단열패널의 심재는 진공압력을 버티고, 낮은 열전도율을 가져야 하므로 기포콘크리트를 채택하였다. 하지만 예비 실험을 통해 기포의 양이나 성질에 의해 0.001torr에 도달하는 시간이 다른 것을 확인하였다. 이러한 영향은 기포제의 종류 및 기포 슬러리 밀도 등에 의해 진공도달시간이 달라질 것이라 판단하여 최적 기포콘크리트 조건이 필요하다. 따라서 본 연구에서는 금속진공단열패널의 심재인 기포큰크리트의 기포제 종류 및 기포 슬러리 밀도에 따라 진공도달시간 및 열전도율 변화를 측정하여 심재로 적용 가능한 기초적 자료를 제시하는 것을 연구목적으로 한다.

금속-고분자 계면에서의 전하의 거동 (Charge Carrier Behaviour of Metal-Polymer Interface)

  • 윤주호;최용성;안성수;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.373-374
    • /
    • 2008
  • Insulating polymers and their composites have been widely used in various electric apparatus or cables. Recently, the effects of interfaces (metal/insulator or insulator/insulator interfaces) on electrical insulation have attracted much attention. However, interfacial phenomena in actual insulation systems and their physical backgrounds are not well understood yet. In this paper, the behaviour of charge carriers near the metal/polymer interface and its effects on conduction and breakdown phenomena are discussed. The metal/polymer interface strongly affects carrier injection, space charge formation and breakdown phenomena. Based on their experimental results, the physical backgrounds of the interfacial phenomena are explained.

  • PDF

원전용 금속단열재의 내부 형상결정을 위한 설계인자 별 열전달 특성 분석 (Analysis of Heat Transfer Characteristics Based on Design Factors for Determining the Internal Geometry of Metal Insulation in Nuclear Power Plant)

  • 송기오;유정호;이태호;전현익;하승우;조선영
    • 대한기계학회논문집A
    • /
    • 제39권11호
    • /
    • pp.1175-1181
    • /
    • 2015
  • 일반적으로 산업현장에서 많이 사용되고 있는 단열재는 유리섬유와 같은 열전도도가 낮은 재료를 사용함으로써 단열성능을 확보하고 있다. 이와 달리 원전용 금속단열재의 경우 높은 열전도도를 가진 TP 304 스테인리스 박판을 재료로 한정하고 있어 단열성능을 확보하기 위해서는 구조적 측면에서의 접근이 필요하다. 본 연구에서는 금속단열재 내부구조에 대한 설계인자를 전도, 대류, 복사로 구성된 3가지 열전달 모드를 고려해 추출하고 각 인자들이 열전달에 미치는 영향과 각각의 열전달이 전체 열전달에 차지하는 비율을 열 유동해석을 이용하여 파악하고자 하였다. 본 연구를 통해 단열재 내부에서 발생되는 대류현상을 최소화하기 위해 다수의 박판을 삽입함과 동시에 증가하는 전도 비율을 비교하여 내부형상결정을 위한 세 가지 열전달 모드 하에서의 단열성능을 분석하였다.