• 제목/요약/키워드: metal flow

검색결과 1,270건 처리시간 0.031초

심층혼합기둥체 차수벽을 이용한 중금속 오염물질의 이동 제어 (Containing Heavy Metal Contaminants Using Soil-Cement Column Barrier)

  • 정문경;천찬란;이주형;김강석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.821-826
    • /
    • 2003
  • Laboratory experiments were peformed to understand physical properties of soil-cement column under the influence of acidic flow including metal contaminants and its retaining capacity against metal migration. The contaminant used in this study was nitric acid with Cu and Cd. The Permeability of soil-cement column decreased when pH of the column began to drop below 12. Decreases in pH led to significant reduction of compressive strength of clayey soil-cement specimen, while relatively marginal reduction for sandy soil-cement specimen. The metal contaminants did not leachate from soil-cement column until pH of soil-cement dropped below 7∼8 for Cu and 9∼10 for Cd. Metal contaminants were precipitated and trapped inside the soil-cement column at pHs higher than those mentioned as verified with metal analysis and visual inspection. This indicated that soil-cement column not only performs well as a cut-off wall, but also helps alleviating the level of contamination of the surrounding environment.

  • PDF

Thixoforming을 위한 금속 복합재료의 다단 재가열 공정 (Multi-Step Reheating Process of Metal Matrix Composites for Thixoforming)

  • 허재찬;강충길
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.180-183
    • /
    • 1997
  • The forming process of metal matrix composites by the die casting and squeeze casting process are limited in size and dimension in term of final parts without machining. The thixoforming process for metal matrix composites has numerous advantages compared to die casting, squeeze casting and compocasting. The characteristics of thixoforming process can decrease the liquid segregation because of he improvement in fluidity in a globular microstructure state and utilizes flow without air entrapment. Therefore, in order to obtain the sound parts of metal matrix composites by using thixoforming process which as co-existing solidus-liquidus pahse, it si very important to obtain reheating condition. However, for he thixoforming process, the billet with the desired volume fraction must be heated to obtain a uniform temperature distribution over the entire cross-sectional areas. To obtain the reheating conditions of composites, the particulate reinforced metal matrix composites for thixoforming were fabricated by combined stirring process which is simultaneously performed with electro-magnetic stirring process which is simultaneously performed with electro-magnetic stirring and mechanical stirring process.

  • PDF

발포 금속을 사용하는 채널의 열전달 특성 실험 및 해석 (Experiment and Analysis on the Heat Transfer Characteristics of a Channel Filled with Metal Form)

  • 손영석;신지영;조영일
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.448-453
    • /
    • 2010
  • Porous media containing complex fluid passage have especially large surface area per unit volume. This study is aimed to identify the heat transfer characteristics of high-porosity metal foams in a horizontal channel. Experiment is performed under various heat flux, velocity and pore density. Nusselt number decreases with higher pore density. Metal foams shows higher heat transfer coefficients than pin-fin structure with the same porosity. This is due to the more complex flow passage and larger heat transfer area based on the structure of the metal foams. The analysis on the pin-fin structure may not be suitable to the metal foam structure but should be identified extensively through further study.

액체 금속 구동용 선형유도전자램프의 자속밀도 분포 해석 (Flux Density Analysis of Linear Induction Electromagnetic Pumps for Liquid Metal)

  • 장남영;은재정;박태봉;최훈기;유근종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.906-908
    • /
    • 2003
  • A Linear induction electromagnetic(EM) pump of liquid metal fast breeder reactor(LMFBR) is used for the purpose that the liquid metal of high temperature is transported by EM force. This paper evaluates magnetic flux density necessary for transporting liquid metal, using analytical model of the linear induction EM pump. Using the 2-D finite element method(2-D FEM), magnetic flux density is estimated in consideration of a geometric model, electric parameter, and velocity of liquid metal. From the viewpoint of hydrodynamics, the results can be used for flow analysis of the liquid metal.

  • PDF

Surface Plasmon Effect in Hot Electron Based Photovoltaic Devices

  • 이영근;정찬호;박종혁;박정영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.162-162
    • /
    • 2011
  • Nanometer-sized noble metals can trap and guide sunlight for enhanced absorption of light based on surface plasmon that is beneficial for generation of hot electron flows. A pulse of high kinetic energy electrons (1-3 eV), or hot electrons, in metals can be generated after surface exposure to external energy, such as in the absorption of light or in exothermic chemical processes. These energetic electrons are not at thermal equilibrium with the metal atoms. It is highly probable that the correlation between hot electron generation and surface plasmon can offer a new guide for energy conversion systems [1-3]. We show that hot electron flow is generated on the modified gold thin film (<10 nm) of metal-semiconductor (TiO2) Schottky diodes by photon absorption, which is amplified by localized surface plasmon resonance. The short-circuit photocurrent obtained with low energy photons (lower than bandgap of TiO2, ~3.1-3.2 eV) is consistent with Fowler's law, confirming the presence of hot electron flows. The morphology of the metal thin film was modified to a connected gold island structure after heating to 120, 160, 200, and 240$^{\circ}C$. These connected island structures exhibit both a significant increase in hot electron flow and a localized surface plasmon with the peak energy at 550-570 nm, which was separately characterized with UV-Vis [4]. The result indicates a strong correlation between the hot electron flow and localized surface plasmon resonance with possible application in hot electron based solar cells and photodetectors.

  • PDF

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

Bi-directional Two Terminal Switching Device with Metal/P/N+or Metal/N/P+ Junction

  • Kil, Gyu-Hyun;Lee, Sung-Hyun;Yang, Hyung-Jun;Lee, Jung-Min;Song, Yun-Heub
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.386-386
    • /
    • 2012
  • We studied a bilateral switching device for spin transfer torque (STT-MRAM) based on 3D device simulation. Metal/P/N+or Metal/N/P+ junction device with $30{\times}30nm2$ area which is composed of one side schottky junction at Metal/P/N+ and Metal/N/P+ provides sufficient bidirectional current flow to write data by a drain induced barrier lowering (DIBL). In this work, Junction device confirmed that write current is more than 30 uA at 2 V, It is also has high on-off ratio over 105 under read operation. Junction device has good process feasibility because metal material of junction device could have been replaced by bottom layer of MTJ. Therefore, additional process to fabricate two outer terminals is not need. so, it provides simple fabrication procedures. it is expected that Metal/P/N+ or Metal/N/P+ structure with one side schottky junction will be a promising switch device for beyond 30 nm STT-MRAM.

  • PDF

알루미늄 합금의 소실모형주조 시 유동도에 미치는 주조 조건의 영향 (The Effect of Casting Conditions on the Fluidity during Lost Foam Casting of Al Alloy)

  • 신승렬;한상원;이경환;이진형
    • 한국주조공학회지
    • /
    • 제24권1호
    • /
    • pp.34-39
    • /
    • 2004
  • The effects of casting condition and hot melt glue during Lost Foam Casting were investigated on the fluidity of Al alloy melt. The fluidity increased linearly with increasing pouring temperature in thick castings but non-linearly in thin casting due to the difference in main heat flow direction. The metal flow velocity was in range of $0.5{\sim}2.7$ cm/s in no evacuation condition and the minimum value of it was measured after the melt flow through the hot melt barrier. The mold evacuation improved the metal flow velocity by around $0.5{\sim}1$ cm/s. And the reaction zone layer thickness was about 1 cm in no-evacuation conditions but about 0.6 cm in mold evacuation condition of 710 torr due to the easier removal of pyrolsis product of EPS. And hot melt barrier thickness of 0.6 mm increased the reaction zone layer thickness up to about 2.5 cm. The fluidity decreased remarkably with an enlarged thickness of hot melt due to a lot of pyrolysis products.