• Title/Summary/Keyword: metX

Search Result 148, Processing Time 0.026 seconds

A study on the fixation of heavy metals with modified soils in the landfill liner (개량혼합토를 이용한 폐기물 매립지 차수층의 중금속 고정능력에 관한 연구)

  • 노회정;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.63-71
    • /
    • 2002
  • The authors selected the modified soil method, and then performed the geotechnical and environmental laboratory test, and evaluated whether the modified soil liner could be accepted as a barrier layer in landfill. Unlike the results of the natural soil(CL), those of the hydraulic conductivity test of stabilized soil met the standard value. According to these results, the optimal mixing ratio of a mixture(cement : bentonite : stabilizing agent) was 90 : 60 : 1 with mass ratio(kg) for 1㎥ with soil, and it was possible to use poor quality bentonite. B\circled2 because of a little difference from results with high quality bentonite. B\circled1. The Cation Exchange Capacity(CEC) of the modified soil was increased about 1.5 times compared with the natural soil; however. the change of CEC with a sort of additives was not detected. In order to observe the change of the chemical components and crystal structures, the natural and the modified soils with the sorts of additives were measured by the XRF(X-Ray Flourescence Spectrometer) and SEM, but there was no significant change. The artificial leachate with the heavy meals ($Pb^{2+}$ , $Cu^{2+}$, $Cd^{2+}$ Zn$^{2+}$ 100mg/L) was passed through the natural soil and modified soils in columns. In the natural soil, Cd$^{2+}$ and $Zn^{2+}$ were identified, simultaneously the pH of outflow was lower, and then came to the breakthrough point. The removal efficiency of the natural soil was showed in order of following : $Pb^{2+}$$Cu^{2+}$ > $Zn^{2+}$ > $Cd^{2+}$ On the other hand, modified soils were not showed the breakthrough condition like the result of the natural soil. The modified soil with the lower quality bentonite, B\circled2(column3) was more stable with respect to chemical attack than that with the higher bentonite, B\circled1(column2) because the change range of outflow pH in columns was less than that of outflow pH in column2. In addition, the case of adding the stabilizing agent(column4) was markedly showed the phenomena.ena.

A Study on the Manual Skills of Experimental Apparatuses of Preservice Elementary School Teachers (초등 예비교사의 실험 기구 조작 능력에 대한 연구)

  • Lee, So-Ree;Choi, Hyun-Dong;Lim, Jae-Keun;Shin, Se-Young;Yang, Il-Ho
    • Journal of Science Education
    • /
    • v.35 no.1
    • /
    • pp.80-90
    • /
    • 2011
  • The purpose of this study is to investigate manual skills of experimental apparatuses of pre-service elementary school teachers by examining and analyzing the process of experiments conducted by pre-teachers. For this study, 24 pre-service elementary school teachers were selected as the subjects and 4 experimental apparatuses were chosen through analyzing science textbooks from 3rd grade to 6th grade in elementary school. The selected experimental apparatuses were alcohol burner, dropper, microscope, instruments for making a prepared specimen. In addition, a task was carefully chosen to conduct an investigation in real settings and a series of evaluation standards was developed. While 3 subjects conducted experiments in separated and independent space at the same time, 3 collaborators observed the experiment process and recorded whether the subject met the evaluation standards or not, using O, X. The study suggests that pre-service elementary school teachers' manual skills of experimental apparatuses were under far below our projections. Particularly, in case of alcohol burner, the subjects showed lower ability to properly light the burners - which is to brush through the lampwick with fire - and to adjust the height of tripods according to the flame. Also, when it comes to dropper, they were not held the way they were supposed to be. In addition, when designing prepared specimen, the subjects used their hands instead of tweezers and often skipped the process of dripping water drop and wiping water with an oilpaper. Moreover, they did not know how to use a microscope properly so there were many times that they could not focus a microscope, failing to observe the objects. Educational implications are discussed.

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

A Case of Child with Obstructive Sleep Apnea Syndrome Recurred after Adenotonsillectomy (편도 및 아데노이드 절제술 후 재발한 폐쇄성 수면 무호흡 증후군 소아 1례)

  • Kim, Cu-Rie;Kim, Dong-Soon;Seo, Hyun-Joo;Shin, Hong-Beom;Kim, Eui-Joong;Shim, Hyun-Joon;Ahn, Young-Min
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.94-99
    • /
    • 2008
  • The most common cause of obstructive sleep apnea syndrome (OSAS) in childhood is adenotonsillar hypertrophy. Adenotonsillectomy improves the symptoms quite well in most cases. However, some patients could experience the OSAS again after adenotonsillectomy, who might have several risk factors such as incomplete operation, misdiagnosis, combined anatomical malformation, sinusitis or chronic allergic rhinitis, obesity, initial severe OSAS, and early onset OSAS. We report a case of 11-year-old obese boy who presented with snoring for several years. He was obese with body mass index (BMI) of $26.3kg/m^2$ and also found to have fatty liver by ultrasonogram. Initial polysomnography (PSG) showed that he met the criteria of severe OSAS with the apnea-hypopnea index (AHI) of 70.5. He underwent adenotonsillectomy and symptoms improved immediately. Four months later symptoms were relieved with AHI of 0, but 1 year after the adenotonsillectomy he started to complain snoring again and the subsequent PSG results showed that OSAS has relapsed with AHI of 43. Paranasal sinus X-ray and physical examination showed sinusitis and re-growth of adenoid. Obesity was proved not to be a contributing factor because his BMI decreased to normal range ($23.1kg/m^2$) after diet control and regular exercise. Also, liver transaminase was normalized and fatty liver was disappeared on follow-up abdominal ultrasonogram. After treatment of sinusitis, symptoms were relieved with decreased AHI (8.5). This case suggests that simple adenotonsillectomy might not be the end of OSAS treatment in childhood. Patients who had adenotonsillectomy should be followed by subsequent PSG if symptoms recur. It is also important to be aware of risk factors in the recurrent OSAS for the proper intervention according to the cause.

  • PDF

Study of Serious Bacterial Infections in Febrile Infants Younger than Three Months of Age (열이 있는 3개월 이하의 영아에서 세균성 감염의 예측에 대한 연구)

  • Jeon, Myeoung Won;Lee, Ji Young;Jang, Young Taek
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.2
    • /
    • pp.215-222
    • /
    • 2003
  • Purpose : This study was to analyze serious bacterial infections in infants younger than three months of age and to review the direction of treatments for these patients. Methods : 378 febrile infants with a rectal temperature ${\geq}38.0^{\circ}C$ visited from Jan. 2001 through Dec. 2002 were retrospectively studied. Infants with the following criteria belonged to the low risk group. WBC $5,000{\sim}15,000/mm^3$, WBC negative in urine stick test and negative for nitirite test, CSF WBC < $10/mm^3$ and negative in CSF gram stain, negative chest X-ray, stool WBC <5/HFP(high power field), and focal infection. If any of the above criteria were not met, they belonged to the high risk group. SBI was defined as a positive culture of urine, blood or CSF. SI was defined as aseptic meningitis or pneumonia including above laboratory tests of SBI. SBI patients were separately compared with two groups, high risk and low risk. Results : Of the 378 infants that were tested 216(57.1%) were in the high risk group and 162(42.9%) in the low risk group. Among 105 SBI(27.8%) and 172 SI(45.5%), there were 98 urinary tract infection(25.2%), 10 bacteremia(2.6%), 2 bacterial meningitis(0.6%), and 77 aseptic meningitis(22.8%). There were 76 SBI(35.2%) from the high risk group and 29 SBI(17.9%) from the low risk group identified. The results of the sensitivity(72.4%), the specificity(48.7%), the negative predictive value(82.1%) and the positive predictive value (35.2%) were calculated. Conclusion : Even though the probability of SBI in the low risk group is insignificant, it should still be considered in febrile infants younger than 3 months of age. I believe the CSF study is necessary because of the moderate high incidence of abnormal finding in our study.

  • PDF

Effect of Dietary Factors on Bone Mineral Density in Korean College Women (한국 여대생의 골밀도에 영향을 미치는 식이 요인 분석)

  • 백희영;송윤주
    • Journal of Nutrition and Health
    • /
    • v.35 no.4
    • /
    • pp.464-472
    • /
    • 2002
  • This study was conducted to investigate dietary and other factors affecting bone mineral density in young Korean collage women. Thirty subjects were recruited; the mean age was 22.1 years and the mean age at menarche was 12.6 years. Bone mineral density (BMD) was measured in the spine (LS), femoral neck (FN), ward's triangle (WT), and femoral trochanter (FT) by Dual Energy X-ray Absorptiometry (DEXA), and physical activity was assessed by a questionnaire. Dietary intake data were obtained 8 times by using a 24 hour recall method to evaluate the subjects' usual diet. Bone mineral densities of lumbar spine, femoral neck, ward's triangle and femoral trochanter were 1.149 g/$\textrm{cm}^2$, 0.980 g/$\textrm{cm}^2$, 0.936 g/$\textrm{cm}^2$ and 0.759 g/$\textrm{cm}^2$ respectively. The met energy intake of subjects was 1,790 kcal, and calcium and iron intakes were found to be inadequate compared to the Korean RDA. The BMD of the lumbar spine was significantly and positively related to the BMI and intake of vitamin C, carbohydrate, potatoes, fruits and plant food. The BMD of the femur (FN, WT, FT) was positively related to the BMI, to carbohydrate and fruit intake, and to the percentage of plant food in total food intake. Multiple recession analysis showed that fruit intake was significantly related to the BMD of the LS. The subjects'ages and fruit intakes were significantly related to the BMD of the femur (FN, WT, FT). These results indicate that higher fruit intakes may have a beneficial effect on bone mineral density.

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

The Effects of Diltiazem and Pentoxifylline on Apoptosis of Irradiated Rat Salivary Gland (흰쥐 침샘의 방사선조사시 Apoptosis에 대한 Diltiazem과 Pentoxifylline의 효과)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.367-375
    • /
    • 1998
  • Purpose : Xerostomia is a complication met by almost all patients who have radiotherapy for cancers of head and neck. Many studies for prevention of xerostomia will be necessary. Radiation-induced acute response of salivary glands has been defined as interphase death or apoptosis. Increased intracellular calcium level have an important role in radiation-induced apoptosis. Calcium channel blocker may prevent radiation-induced apoptosis of salivary glands. This study was designed to evaluate the effectiveness of diltiazem known as calcium channel blocker and pentoxifylline with inhibition of inflammatory response on the apoptosis as an acute response of radiation in rat salivary glands. Materials and Methods : Sprague-Dawley rats with about body weight 200-250 g were divided into 5 study groups : control, radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation. The diltiazen and pentoxifylline were injected intraperitoneally 20 mg/kg and 50 mg/kg, 30 and 20 mimute before irradiation. respectively. Irradiation was given with a 4 MV linear accelerator. The 1600 cGy of radiation was delivered in a single fraction through a single anterior portal encompassing the entire neck. After 24 h of irradiation, rats were sacrificed and parotid and submandibular glands were removed and stained with hematoxylin and eosin. The quantification of apoptosis was performed by microscopic examination of stained tissue sections at a magnification of 200X and the percentage of apoptotic cell was calculated. Results : On parotid glands, the percentage of apoptosis by radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.72$\%$ (8.35/486), 0.64$\%$ (2.9/453), 0.23$\%$ (1.2/516), and 0.28$\%$ (1.1/399), respectively. The apoptosis was markedly reduced in the groups receiving drugs compared with groups receivinge, radiation alone (p<0.05). In serous cell of submandibular glands, the percentages of apoptosis of radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.94$\%$ (l1/567), 0.34$\%$ (1.9/554), 0.28$\%$ (1.8/637), and 0.22$\%$ (1.3/601), respectively. In the mucus cell of submandibular glands, the percentages of apoptosis were 0.92$\%$ (5.1/552), 0.41$\%$ (2.5/612), 0.29$\%$ (1.3/455), and 0.18$\%$ (1.0/562), respectively. The apoptosis was markedly reduced in the serous glands (p<0.05), but there was no difference in development of apoptosis in each group of mucus gland. Conclusion : These results suggest that radiation-induced apoptosis of serous cells of salivary glands may be decreased by diltiazem and pentoxifylline administration.

  • PDF