• Title/Summary/Keyword: mesiobuccal

Search Result 82, Processing Time 0.029 seconds

Comparison of panoramic radiography and cone-beam computed tomography for assessing radiographic signs indicating root protrusion into the maxillary sinus

  • Jung, Yun-Hoa;Cho, Bong-Hae;Hwang, Jae Joon
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.309-318
    • /
    • 2020
  • Purpose: This study investigated correlations between findings on panoramic radiographs and cone-beam computed tomography (CBCT) to assess the relationship between the maxillary sinus floor and the roots of maxillary posterior teeth. In addition, radiographic signs indicating actual root protrusion into the maxillary sinus were evaluated on panoramic radiographs. Materials and Methods: Paired panoramic radiographs and CBCT images from 305 subjects were analyzed. This analysis classified 2,440 maxillary premolars and molars according to their relationship with the maxillary sinus floor on panoramic radiographs and CBCT images. In addition, interruption of the sinus floor was examined on panoramic radiographs. Results: Root protrusion into the maxillary sinus occurred most frequently in the mesiobuccal roots of the second molars. The classification according to panoramic radiographs and CBCT images was the same in more than 90% of cases when there was no contact between the root apex and the sinus floor. When the panoramic radiograph showed root protrusion into the sinus, the CBCT images showed the same classification in 67.5% of second molars, 48.8% of first molars, and 53.3% of second premolars. There was a statistically significant relationship between interruption of the sinus floor on panoramic radiographs and root protrusion into the sinus on CBCT images. Conclusion: The presence of root protrusion into the sinus on panoramic radiographs demonstrated a moderate ability to predict root protrusion into the maxillary sinus. Interruption of the maxillary sinus floor could be considered an indicator of actual root protrusion into the maxillary sinus.

A STUDY FOR OCCLUSAL FEATURES OF FIRST PERMANENT MOLAR AND SECOND PRIMARY MOLAR (제 1대구치와 제 2유구치의 교합면 양상에 관한 연구)

  • Jeon, So-Hee;Kim, Jae-Gon;Yang, Yeon-Mi;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.89-100
    • /
    • 2005
  • The purpose of this study was to analyze the morphometrics of primary second molar and permanent first molar. Samples were consisted of normal occlusion in the primary dentition(50 males and 50 females) and permanent dentition(43 males and 43 females). Their upper and lower plaster casts were used and their measuring points were decided, through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), fitting standard horizontal plane were made for measuring the intercuspal distance, volume of intercuspal area and section curve. The results were as follows; 1. Average distance from the fit plane to the cusp tips of mandibular primary second molar was smaller than any other tooth. (0.05-0.09 mm in male and 0.04-0.09 mm in female). 2. Intercuspal distances of mandibular primary second molar and permanent first molar were larger in male than in female. Especially, there was statistical significance in primary second molar(p<0.05). 3. Intercuspal distance between distobuccal and distolingual cusp was larger in maxillary primary second molar, except cross intercuspal distances. And distances between distal and distolingual cusp, in mandibular primary second molar, between mesiolingual and mesiobuccal cusp, in maxillary first molar, and between distolingual and mesiolingual cusp, in mandibular first molar were larger than any other intercuspal distance. 4. Volume of intercuspal area of primary second molar and permanent first molar was larger in mandible than in maxilla and that of permanent first molar was 1.40-1.75 times of primary second molar (p<0.05). Also it was larger in male than in female, but there was no statistical significance. 5. In most cases, section curves were wider and deeper in permanent dentition than in primary dentition. Except cross intercuspal distances, in maxilla, section curve between mesiobuccal and mesiolingual cusp was the deepest in both dentition. In mandible, section curve between distobuccal and distal cusp was the deepest in permanent dentition and between distolingual and distal cusp was the deepest in primary dentition.

  • PDF

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

The Influence of Home Position(H.P.) and Random Position(R.P.) on the Shape of Prepared Tooth Surfaces -Upper Left 1st Molar for Full Cast Crown- (시술자세가 치관 삭제면 형태에 미치는 영향 -상악 좌측 제 1 대구치의 전부 주조관-)

  • Lee, Seung-Jeong;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.257-274
    • /
    • 2001
  • To properly prepare teeth, dentists require a direct view of the working area and are often placed in a difficult position, moreover, a high proportion of dentists suffer from headache and back pain. Dentists who make use of the dental mirror and position their patients carefully to gain a proper view report less headache, pain and discomfort in the shoulders. It is recommended that dentists learn the "Home Position(H.P.)" which among the various "Random Position(R.P.)" methods, enables dentists to approach their patients in a stable posture. The purpose of this study was to compare tooth preparation in the H.P. and the R.P., and evaluate the clinical efficacy of the H.P.. Tooth preparation for a full cast crown was performed on the maxillary left 1st molar using the H.P. and the R.P., and the shapes of the prepared tooth surfaces at the two different operating positions were compared. The amount of occlusal reduction, marginal width, height, and axial taper were measured and analyzed. A T-test was performed separately to compare the results of the H.P. and the R.P. with respect to the accuracy of the corresponding tooth reduction. The results were as follows. ; 1. The amount of occlusal reduction was excessive on the mesiobuccal cusp(P<0.05), and deficient on the lingual cusp in the H.P.(P<0.01). In the R.P., this was excessive on the buccal cusp and deficient on the fossa and distolingual cusp(P<0.01). 2. The amounts of marginal width were excessive in all areas except on the lingual and mesial surfaces in the H.P. and lingual surface in the R.P.(P<0.01). 3. The marginal heights were achieved more accurately in the R.P. than the H.P.(P<0.01). 4. Axial surface taper was excessive in all areas in the H.P.(P<0.01). But the axial taper of measured areas was even, and tooth is more like to retain its original axis after reduction. In the R.P., axial surface taper was excessive on the mesial and buccal area, and deficient on the distolingual area(P<0.01), and therefore, the axis of the prepared teeth was tipped in the distolingual direction. 5. The times needed for preparation were 12 minutes and 49 seconds in the H.P., and 11 minutes and 35 seconds in the R.P., and the R.P. was statistically faster(P<0.01). The tooth preparation in the H.P. achieved its goal, in that it enabled the operator to make even tooth reduction. In conclusion, the H.P. system offers an improved method that can be used in clinic after specific training.

  • PDF

An analysis of the dental arch and skeletal characteristics in adult patients exhibiting open bite (Openbite을 나타내는 성인의 치열 특성 및 그에 따른 골격적 특성 분석)

  • Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.289-301
    • /
    • 2004
  • It is the purpose of this study to characterize oral symptoms and to comprehend the cause and the relapse possibility of patients with open bite. This case study examines the orthodontic treatment of a group of female patients with open bite and Angle's Class I malocclusion. A cephalograph of the patient was taken and tracing of the radiograph was completed. In addition to Bjork and Ricketts analysis, additional measurements of specific areas were taken. The occlusal plane was determined by drawing a line connecting the mesiobuccal cusp tip of the maxillary first molar and the incisal edge of the maxillary central incisors. Patients were divided into two groups depending on the relationship between the marginal ridge of the maxillayy first premolar and the drawn line. Those patients with marginal ridges above the occlusal plane were placed into Group 1, while Group 2 subjects exhibited marginal ridges lower than the occlusal plane. The common characteristics within each group and the characteristic differences between each group both prior to and after orthodontic treatment were examined, and finally, the functional oral volume of each patient was analyzed. The results of the case study were as follows: 1. An examination of the skeletal relationship and anatomical form for both Group 1 and 2 showed that all subjects exhibited hyperdivergent skeletal forms, but Group 2 subjects generally demonstrated underdevelopment of the mandible and a smaller articular angle, resulting in an anterior positioning tendency of the mandible. 2. An analysis of the maxillary arches of Group 1 subjects prior to and after orthodontic treatment showed that the antero-inferior direction had changed to an antero-superior directional tendency, while the maxillary arches of the Group 2 patients showed a trend from an antero-superior direction to an antero-inferior relationship. The mandibular arches in both groups showed a change to an antero-superior direction. 3. Functional space analysis showed that Group 2 patients exhibited a greater tendency of haying palatal planes that drop in a postero-inferior direction, resulting in a more severe open bite than their Group 1 counterparts. The results of this case study show that although patients belonging to either Group 1 or 2 exhibited few external differences in the appearance of open bite, an examination of the dental and skeletal relationships by analyzing patient cephalographs showed that patients presenting with flat maxillary occlusal planes exhibited more severe open bite relationships than patients with curved occlusal planes.

A Comparison of Stainless-Steel File and MFile-System® Ni-Ti Rotary Instrument in Canal Preparation using Dental Computed Tomography (치과용 단층촬영을 이용한 Stainless-Steel File과 MFile-System® 전동식 기구의 근관 성형 능력에 대한 비교 연구)

  • Seo, Dong-Jin;Yoon, Mi-Ran;Lee, Rin;Yu, Mi-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.173-180
    • /
    • 2006
  • Objectives The aim of this study is to compare the quality of root canal preparation completed using MFile-$System^{(R)}$ instrument ( Komet, Gebr.Brsaseler, Germany) and conventional stainless steel file in the canals of Maxillary molar teeth that had a canal curvature between $25^{\circ}$ or more Materials & Methods Buccal canals of 24 first and second maxillary molar teeth, extracted for periodontal and prosthetic reasons were used. Tissue fragments and calcified debris were removed from teeth by scaling and the teeth were stored in 10% formalin solution for 24 hour. Then, teeth were stored in saline until used. To be included the roots had to have completed formed apices and angle of curvature ranging between $25^{\circ}$ or more according to the criteria described by Schneider(1971). Palatal and Second mesiobuccal canals were not included. Teeth were embedded into transparent acrylic. The teeth were randomly divided into two experimental groups. All teeth were scanned by Dental CT (PSR9000N, Asahi, Japan) to determine the root canal shape before instrumentation. Image slices were prepared from the apical end point to the pulp chamber. The first two sections were 2 mm from the apical end of root and 2 mm below the orifice. Further section was recorded, dividing the distance between the sections of apical and coronal levels into two equal lengths. 12 teeth were instrumented using stainless steel fileand another 12 teeth were instrumented using MFile-$System^{(R)}$. Following the completion of the instrumentation, the teeth were again scanned and compared with the cross sectional images taken prior to canal preparation. Amount of transportation and centering ability was assessed. Student's t-test was used for statistical analysis. Result Less transportation occurred with MFile-$System^{(R)}$ rotary instrumentation than stainless steel instrument. MFile-$System^{(R)}$ had better centering ability than stainless steel instrument. Conclusion MFile-$System^{(R)}$ rotary instrumentation transported canals less and had good centering ability.

Assessment of Root and Root Canal Morphology of Human Primary Molars using CBCT (CBCT를 이용한 유구치의 치근 및 근관의 형태학적 평가)

  • Choi, Yoomin;Kim, Seonmi;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-35
    • /
    • 2020
  • The purpose of this study is to evaluate the morphological characteristics of the roots and roots canals of primary molar teeth using Cone-Beam Computed Tomography (CBCT). A total of 68 CBCT images of children aged 4 - 5 years was used for this study. A total of 160 molar teeth were analyzed. Various parameters such as the number of roots and canals, length of root and root canal, and the angulation and shape of the roots were analyzed. All maxillary primary molars had 3 roots. The presence of 2 root canals in 1 root was only observed in the mesiobuccal root of maxillary primary second molars. Most mandibular primary molars had 2 roots, and most mesial roots had 2 root canals. Concerning the length of the roots, the palatal root of the maxillary primary molar was found to be longest whereas the distobuccal root was shortest. In mandibular primary molars, the mesial root was longer than the distal root. In maxillary primary molars, the palatal root had the greatest angulation whereas the distal root has the greatest in mandibular molars. The root and root canals of maxillary primary molars were more curved in shape whereas mandibular primary molars were straight.

Positional symmetry of porion and external auditory meatus in facial asymmetry

  • Choi, Ji Wook;Jung, Seo Yeon;Kim, Hak-Jin;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.33.1-33.9
    • /
    • 2015
  • Background: The porion (Po) is used to construct the Frankfort horizontal (FH) plane for cephalometrics, and the external auditory meatus (EAM) is to transfer and mount the dental model with facebow. The classical assumption is that EAM represents Po by the parallel positioning. However, we are sometimes questioning about the possible positional disparity between Po and EAM, when the occlusal cant or facial midline is different from our clinical understandings. The purpose of this study was to evaluate the positional parallelism of Po and EAM in facial asymmetries, and also to investigate their relationship with the maxillary occlusal cant. Methods: The 67 subjects were classified into three groups. Group I had normal subjects with facial symmetry ($1.05{\pm}0.52mm$ of average chin deviation) with minimal occlusal cant (<1.5 mm). Asymmetry group II-A had no maxillary occlusal cant (average $0.60{\pm}0.36$), while asymmetry group II-B had occlusal cant (average $3.72{\pm}1.47$). The distances of bilateral Po, EAM, and mesiobuccal cusp tips of the maxillary first molars (Mx) from the horizontal orbital plane (Orb) and the coronal plane were measured on the three-dimensional computed tomographic images. Their right and left side distance discrepancies were calculated and statistically compared. Results: EAM was located 10.3 mm below and 2.3 mm anterior to Po in group I. The vertical distances from Po to EAM of both sides were significantly different in group II-B (p=0.001), while other groups were not. Interside discrepancy of the vertical distances from EAM to Mx in group II-B also showed the significant differences, as compared with those from Po to Mx and from Orb to Mx. Conclusions: The subjects with facial asymmetry and prominent maxillary occlusal cant tend to have the symmetric position of Po but asymmetric EAM. Some caution or other measures will be helpful for them to be used during the clinical procedures.

LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS (대구치에서 회전식 NiTi file의 수명과 파절양상)

  • Kim, Jin-Woo;Ahn, Byung-Doo;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.184-192
    • /
    • 2005
  • Intracanal separation of the rotary files is a serious concern in modern endodontic practice. The objective of this study was to compare the life span and fracture patterns of three NiTi rotary files in molar teeth Mesiobuccal roots of upper molar (n = 150) and mesial roots of lower molar (n = 150) were divided into three groups and each group was prepared with Profile, ProTaper, and K3 respectively. Every file was used until separation and/or deterioration of the cutting blade was happened, and then the number of canals to separation and/or unwinding were recorded. Radiographs and Scanning electon microscope (SEM) photographs were taken to evaluate the patterns of separation. The results were as follows: 1. There were no significant differences in numbers of canals to separation and/or unwinding among the groups. 2. Comparing between flaring files, K3 showed significant lower numbers of canals to separation and/or unwinding (p < 0.05), and there was no significant difference between shaping files 3. Separations of instruments were occurred at the midpoint of curvatures within the canals 4. In SEM observations, ductile fractures were seen in most of cases, characterized by shallow dimples. Additional researches is needed to provide a new guideline that informs the appropriate number of times to use NiTi files.