• 제목/요약/키워드: membrane resistance

검색결과 859건 처리시간 0.024초

망간과 휴믹산에 의한 세라믹 막 오염의 제어를 위한 약품 스팀세정의 적용 (Chemically enhanced steam cleaning for the control of ceramic membrane fouling caused by manganese and humic acid)

  • 안선아;박철규;이진산;김한승
    • 상하수도학회지
    • /
    • 제35권6호
    • /
    • pp.425-436
    • /
    • 2021
  • In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, R c/R f increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.

Polysulfone과 Poly(Phenylene Sulfide Sulfone)의 블록 공중합체를 이용한 양이온 교환막의 제조 및 전기화학적 특성 (Preparation of Cation Exchange Membrane using Block Copolymer of Polysulfone and Poly(Phenylene Sulfide Sulfone) and its Electrochemical Characteristics)

  • 임희찬;강안수
    • 멤브레인
    • /
    • 제10권2호
    • /
    • pp.66-74
    • /
    • 2000
  • In consideration that a high tensile strength and ion exchange capacity are maintained as the swelling of membrane is controlled by the coagulation of PSf with the introduction of ion exchange groups and PPSS without the introduction of ion exchange groups, the block copolymer of PSf and PPSS were synthesized. The cation exchange membrane was prepared by sulfonation with CSA and casted. The synthesized block copolymer and cation exchange membrane were characterized by FT-IR and their thermal stability was confirmed by TGA. The optimum sulfonation could be accomplished at a mole ratio of BPSf to CSA 1:3. The best electrochemical properties obtained by the optimal condition were area resistance of 4.37 $\Omega$$\textrm{cm}^2$, ion exchange capacity of 1.71 meq/g dry membrane, water content of 0.2941 g $H_2O$/g dry membrane, and fixed ion concentration of 5.81 meq/g $H_2O$. When GBL was used as an additive, area resistance was increased by 13.7 % and ion exchange capacity was increased by 14.6%. When the membrane was fabricated in a form of composite using non woven cloth as a support. the tensile strength of membrane could be improved, but the electrochemical characteristics were not influenced.

  • PDF

Performance Evaluation of Platinum Dispersed Self-humidifying Polymer Electrolyte Membrane Prepared by Using RF Magnetron Sputter

  • Kwak, Sang-Hee;Yang, Tae-Hyun;Kim, Chang-Soo;Yoon, Ki-Hyun
    • 한국세라믹학회지
    • /
    • 제40권2호
    • /
    • pp.118-122
    • /
    • 2003
  • The performance evaluation on Pt loading in the self-humidifying polymer electrolyte membrane for Polymer Electrolyte Mem-Brane Fuel Cell(PEMFC) was investigated by using single cell test and measurement of membrane resistance. The self-humidifying membrane comprised two membranes made of perfluorosulfonylfluroride copolymer resin and fine Pt particles tying between them, coated by sputtering. From the results of performance characteristics of self-humidifying membrane cell with different Pt loading, a single cell using self-humidifying membrane with 0.15 mg/$\textrm{cm}^2$ Pt loading showed better performance than that with the others over entire current density. Also, a single cell with 0.15 mg/$\textrm{cm}^2$ Pt loading had a lower resistance value than the other cells under externally nonhumidifying condition. It is indicated that the water produced in the membrane cell with 0.15 mg/$\textrm{cm}^2$ Pt loading showed a higher provision to maintain ionic conductivity of the membrane than the other cells. The optimum amount of Pt particles embedded in the membrane for self-humidifying PEMFC was determined to be about 0.15 mg/$\textrm{cm}^2$.

막 오염 저항성이 우수한 나노 소재 정밀 여과막의 특성 연구 (Characterization of the Nano-material U Membranes with Excellent Fouling Resistance)

  • 최정환;이정빈;김인철
    • 멤브레인
    • /
    • 제15권4호
    • /
    • pp.289-296
    • /
    • 2005
  • MBR 공정에서 가장 문제시되는 부분은 실제 공정상에서 막 표면에 오염이 발생하는 문제이다. 일반적으로 막 오염은 활성 슬러지들이 막 표면에 퇴적되어서 일어나며 이로 인해 심각한 투과 유량의 감소를 야기하게 된다. 본 연구에서는 막 오염 저항성이 뛰어난 나노 입자를 분리막 표면에 함침시켜 MBR 막을 제작하였으며 이 입자들은 막 표면에서 활성 슬러지들이 쉽게 달라 붙지 못하는 역할을 수행하게 된다. 즉, 뛰어난 투수량을 지닌 정밀여과막에 나노 입자를 첨가함으로서 실제 MBR 공정에서 막 오염을 저감시킴으로서 투수량을 보전할 수 있게 하였다. 이들을 이용하여 MBR 공정에서 막 오염이 휠씬 적게 일어나는 것을 확인하였으며 이를 바탕으로 현장에 적용하여 막 오염 저항성을 확인하였다.

Noble Metal이 코팅된 금속분리판 개발 및 성능 평가 (Development and Evaluation of Bipolar Plates Coated with Noble Metals for Polymer Electrolyte Membrane Fuel Cells)

  • 서하규;한인수;정지훈;김민성;신현길;허태욱;조성백
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.90.2-90.2
    • /
    • 2010
  • The coated metallic bipolar plates are getting attractive due to their good feasibility of mass production, low contact resistance, high electrical/thermal conductivity, low gas permeability and good mechanical strength comparing with graphite materials. Yet, metallic bipolar plates for polymer electrolyte membrane(PEM) fuel cells typically require coatings for corrosion protection. Other requirements for the corrosion protective coatings include low electrical contact resistance between metallic bipolar plate and gas diffusion layer, good mechanical robustness, low mechanical and fabrication cost. The authors have evaluated a number of protective coatings deposited on stainless steel substrate by electroplating. The coated metallic bipolar plates are investigated with an electrochemical polarization tests, salt dipping tests, adhesion tests for corrosion resistance and then the contact resistance was measured. The results showed that the selective samples electroplated with optimized method, satisfied the DOE target for corrosion resistance and contact resistance, and also were very stabilized in the typical fuel cell environments in the long-term.

  • PDF

금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감 (Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation)

  • 김종오;정종태
    • 멤브레인
    • /
    • 제14권1호
    • /
    • pp.66-74
    • /
    • 2004
  • 합성 하수 및 실제 하수를 이용한 금속 막의 정밀 여과 공정에서 분리 막의 전체 저항의 증가는 입자의 막 표면 축적에 의한 케이크 층의 저항 ($R_c$)에 가장 큰 영향을 받았다. 막 오염 저감을 위한 방법으로 오존 가스를 이용한 간헐적 역세정은 공기에 의한 경우보다 막 오염 저감에 훨씬 더 효과적인 것으로 나타났다. 운전 인자에 대한 영향으로 동일한 오존 주입량에서는 주입시간을 길게 하기보다는 주입 가스 유량을 크게 할수록 더 높은 막 투과 유속의 회복을 보였다. 여과시간이 길수록 오존가스를 이용한 막 오염 저감효과가 감소하는 것으로 나타나 부착층 및 막 내부에서 파울링 물질에 의한 비가역적인 막 오염이 발생하기 전에 막 세정을 실시하는 것이 바람직한 것으로 판단된다.

액적의 충격력 측정을 위한 유연 멤브레인 센서의 PDMS 변형에 의한 민감도의 영향 (The Effect of the Deformation on the Sensitivity of a Flexible PDMS Membrane Sensor to Measure the Impact Force of a Water Droplet)

  • 강동관;이상민
    • 한국기계가공학회지
    • /
    • 제21권5호
    • /
    • pp.16-21
    • /
    • 2022
  • This study investigates the effect of the deformation on the sensitivity of a flexible polydimethylsiloxane (PDMS) membrane sensor. A PDMS membrane sensor was developed to measure the impact force of a water droplet using a silver nanowire (AgNW). The initial deformation of the membrane was confirmed with the application of a tensile force (i.e., tension) and fixing force (i.e., compressive force) at the gripers, which affects the sensitivity. The experimental results show that as the tension applied to the membrane increased, the sensitivity of the sensor decreased. The initial electrical resistance increased as the fixing force increased, while the sensitivity of the sensor decreased as the initial resistance increased. The movement of the membrane due to the impact force of the water droplet was observed with a high-speed camera, and was correlated with the measured sensor signal. The analysis of the motion of the membrane and droplets after collision confirmed the periodic movement of not only the membrane but also the change in the height of the droplet.

PTFE 막의 표면 개질 방법 (Surface Modification of Poly(tetrafluoroethylene) (PTFE) Membranes)

  • 장준규;윤채원;박호범
    • 멤브레인
    • /
    • 제33권1호
    • /
    • pp.1-12
    • /
    • 2023
  • 본 총설은 소수성 불소수지계 분리막의 표면 개질에 대한 개론으로 다양한 표면 개질 방법 및 그 연구 결과를 중점적으로 서술하였다. PTFE로 대표되는 불소수지계 고분자 분리막은 막 증류, 유수 분리, 기체 분리를 포함한 다양한 막 분리 공정에서 사용되어왔다. PTFE 막은 내화학성, 내열성, 높은 기계적 강도와 같은 뛰어난 물성에도 불구하고 소수성 표면 특성으로 인해 기술 적용의 확장에 제한적이다. 친수성 향상을 위해 습식 화학법, 친수성 고분자 코팅, 플라즈마 처리, 조사, 원자층 증착과 같은 다양한 PTFE 표면 개질 방법을 이용하며 이를 통해 불소수지계 분리막의 응용분야가 확장될 수 있다.

우레탄계와 아크릴계 도막 방수재가 도포된 바탕 모르타르의 염해 저항성 평가 (Salt damage resistance of mortar substrate coated by the urethane and acrylic waterproofing membranes)

  • 이준;미야우치 히로유키;구경모;최경철;미야우치 카오리;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.329-331
    • /
    • 2013
  • The salt damage resistance of waterproofing membrane was evaluated on the cracked mortar substrate. The types of specimens are urethane, acrylic waterproofing membrane, and no coating mortar substrate. After these specimens were cured by water curing for 4 weeks, they were cured by atmospheric curing at 20±2Co for 8 weeks. The salt water immersion test was carried out by following KS F 2737, and the penetration depth of chloride ion into substrate was measured in 1, 4, 8, and 13 weeks. As a result, in the case of non coating specimen, the chloride ion penetrated within one week. In the coated specimens, a regardless of the membrane type, the chloride ion did not penetrate during 13 weeks-tests on condition that the cracked width of substrate is less than 0.3mm. Also, the penetration speeds of the coated specimens were lower than that of non coating specimen. Therefore, our results reached a conclusion that waterproofing membrane has high salt damage resistance.

  • PDF