• Title/Summary/Keyword: membrane performance

Search Result 1,790, Processing Time 0.028 seconds

Factors Affecting Biofouling in Membrane Coupled Sequencing Batch Reactor

  • Lee, Chung-Hak
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.7-10
    • /
    • 2003
  • Factors affecting filtration performance were investigated in a Sequencing Batch Reactor (SBR) coupled with a submerged microfiltration module. Special bioreactors for aerobic and anoxic phases, respectively, were specifically designed in order to differentiate tile effect of Dissolved oxygen (DO) from that of mixing intensity on membrane filterability. DO concentration as well as mixing intensity proved to have a major influence on the membrane performance regardless of the SBR phase. A higher DO concentration resulted in a slower rise in TMP, corresponding to less membrane fouling.

  • PDF

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber (PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer (멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구)

  • Oh, Mi-Hyun;Kwon, Shi-Won;Kang, Hyo-Jin;Jung, Hee-Won;Choi, In-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance quality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer (멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance duality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

Surfactant enhanced filtration performances of monochlorophenol isomers through low-pressure membrane

  • Kumar, Yogesh;Brahmbhatt, H.;Trivedi, G.S.;Bhattacharya, A.
    • Membrane and Water Treatment
    • /
    • v.2 no.3
    • /
    • pp.137-145
    • /
    • 2011
  • Membrane processes are major breakthrough for the removal of organic pollutants in water remediation. The separations of solutes depend on nature of the membranes and solutes. The separation performance depends on the nature of the solutes (i.e., molecular volume, polarity, and hydrophobicity) for the same membrane. As 4-chlorophenol is of more dipolemoment compared to 2-chlorophenol, the orientation of the molecule enables it pass through the pores of the membrane, which is of negatively charged and thus separation order follows: 2-chlorophenol > 4-chlorophenol. Hydrophobicity factor also supports the order. Addition of sodium dodecyl sulfate (SDS) to chlorophenol solution shows remarkable increase in separation performance of the membrane. The improvement in separation is 1.8 and 1.5 times for 4- and 2- chlorophenol consecutively in case of 0.0082 M SDS (1cmc = 0.0082 M) in the solution. 4-chlorophenol has better attachment tendency with SDS because of its relatively more hydrophobic nature and thus reflects in performance i.e. the separation performance of 4-chlorophenol with SDS through the membrane is better compared to 2-chlorophenol.

The Effect of Leaflet Elasticity on the Hydrodynamic Performance of Trileaflet Prosthetic Valves (삼엽인공판막 leaflet 탄성도가 수력학적 성능에 미치는 영향)

  • Seo, J.C.;Rhee, K.H.;Lee, S.H.;Ahn, H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.109-112
    • /
    • 1997
  • The Hydrodynamic performance of the trileaflet polymer prosthetic valves depends on the design of the leaflet and the physical properties of the leaflet membrane. In order to study the effect of leaflet membrane elasticity on the hemodynamic performance of trileaflet prosthetic valve, leaflet membranes are manufactured using two different polymers - Biospan and Tecoflex SG-93A. The hemodynamic performance parameters are measured under steady and physiological pulsatile flow, and compared with monoleaflet polymer valve(floating valve) and bileaflet mechanical valve(St. Jude Medical valve). Well designed trileaflet valve shows the lowest mean pressure drop among the tested valves. The trileaflet valves with Biospan membrane show lower pressure drop and back low comparing to those with Tecoflex membrane. More elastic membrane may provide wide opening area during systole and close membrane ree edge contact during diastole. Durability of trileaflet valves are also tested in vitro. Trileaflet valves with non-uniform membrane thickness ail within 17 days because of stress concentration. Trileaflet polymer valves with uniform membrane thickness perform well over 55 days without failure.

  • PDF

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.59-59
    • /
    • 1991
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and CO₂ flow rate CO₂ pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high CO₂ removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

Analysis of Effect on Freshwater Production of Vacuum Membrane Distillation Module according to Housing Leak (중공사막 진공 막증류 모듈의 하우징 누수가 담수 생산에 미치는 영향 분석)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.313-319
    • /
    • 2016
  • In this study, the performance experiment was conducted to compare the permeate flux of hollow fiber Vacuum Membrane Distillation module according to leak problem between module housing and membrane bundle. For the permeate flux performance experiment of the two Vacuum Membrane Distillation modules, the Lab-scale experimental equipment was built in the capacity of $1m^3/day$. The performance test of the two Vacuum Membrane Distillation modules were analyzed according to the feed water conditions. As a result, it was analyzed that the leak VMD module decreased about 14% of permeate flux than normal VMD module.

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 1999
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and {{{{{CO }_{2 } }}}}} flow rate {{{{{CO }_{2 } }}}}} pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high {{{{{CO }_{2 } } }}}} removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

  • PDF