• Title/Summary/Keyword: membrane contactor

Search Result 46, Processing Time 0.027 seconds

Development of High-Permeability Ceramic Hollow Fiber and Evaluation of CH4/CO2 Separation Characteristics of Membrane Contactor Process (고투과성 세라믹 중공사 개발과 접촉막 공정의 CH4/CO2 분리 특성 평가)

  • Lee, Seung Hwan;Kim, Min Kwang;Jeong, Byeong Jun;Zhuang, Xuelong;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.269-275
    • /
    • 2020
  • In this study, CO2 separation experiment was performed on a CH4/CO2 mixed gas using a ceramic hollow fiber membrane contactor (HFMC). In order to fabricate high-performance HFMC, experiments were conducted to manufacture high-permeability hollow fiber membranes, and the prepared hollow fiber membranes were evaluated through N2 gas permeation experiments. HFMC for CH4/CO2 mixed gas separation was manufactured using the manufactured high-permeability hollow fiber membrane. In the experiment, mixed gas of CH4/CO2 (34.5% CO2, CH4 balance) and monoetanolamine (MEA) was used, and the effect of CO2 removal efficiency on the flow rate of the absorbent was evaluated. The CO2 removal efficiency increased as the liquid flow rate increased, and the CO2 absorption flux also increased with the liquid flow rate.

Treatment of ground waters in a hollow-fibre liquid membrane contactor for removal of ions

  • Hossain, Md. M.
    • Membrane and Water Treatment
    • /
    • v.4 no.2
    • /
    • pp.95-108
    • /
    • 2013
  • Metal ions exist in seawater, groundwater and industrial wastewaters. These source waters can be recycled if their concentrations are reduced. A number of processes can be applied for this purpose. Liquid-liquid extraction is one of the promising methods. In this paper, experimental results are presented on the removal of Cr(VI) using Aliquat-336, a reactive carrier, in sunflower oil (a non-toxic solvent). The performance of this new system is compared with those of kerosene (a toxic solvent). The extent of removal of Cr(VI) from samples with high and low concentrations are presented. The process was upgraded to a bench-scale module that can selectively remove about 50-90% Cr(VI) from samples of groundwater. Thus this process can produce water within the acceptable range for recycling and for use in secondary purposes such as irrigation.

Research and Development Trend of Pertraction Process using Membrane (분리막을 이용한 투과추출공정의 연구와 개발 동향)

  • Kim, Deuk Ju;Choi, Whee Moon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.381-394
    • /
    • 2012
  • Recently, a variety of chemical and physical methods are employed to separate ionic materials from complex aqueous. Most of all, membrane pertraction using contactor has been considered as alternative recovery and separation system in field of chemical, petrochemical and medicines because heavy metals, hydrocarbon based materials in contaminants like wastewater can be recovered by pertraction system. Also, pertraction process has characteristics such as ease of operation, lower energy consumption and operational cost, higher selectivity. This work investigates some example of developed membrane and their performance for the application of pertraction process.

CONTROL OF CARBON DIOXIDE REMOVAL RATE BY HOLLOW FIBER MEMBRANE CONTACTOR

  • Lee,Yong-Taek;Cho, Ingi;Lim, Hye-Jin;Ahn, Hyo-Seong;Hahm, Moon-Ky;Park, You-In;Lee, Kew-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.48-51
    • /
    • 1999
  • To investigate numerically the removal behavior of carbon dioxide in a hollow fiber membrane contactor, the system controlling equations were developed including the nonlinear reversible reaction terms. The reversible chemical reactions were incorporated in the system controlling equations, resulting in the coupled nonlinear partial differential equations which could describe either the absorption of the desorption of carbon dioxide. The computer program was coded using the Fortran language and run with a personal computer to find out the effects of the system variables: the pressures of absorbed and desorbed gases, the absorbent flow rate, the concentration of potassium carbonate, the fiber diameter and the length.

  • PDF

Reactive separation of boron using a liquid membrane of diol in vegetable oil

  • Hossain, Md. M.;Maraqa, M.A.
    • Membrane and Water Treatment
    • /
    • v.8 no.1
    • /
    • pp.19-34
    • /
    • 2017
  • Boron exists in dilute concentrations in sea water, ground water and waste waters. Reactive liquid extraction can be used for removing boron to make the treated water suitable for drinking and irrigation, with its final concentration less than 0.5 ppm. The results of equilibrium experiments are reported on the removal of boron using 2-butyl-2-ethyl-1, 3-propanediol (BEPD as a nonionic carrier) in sunflower oil, a non-traditional solvent. The results of removal of boron from aqueous solutions in the concentration range 0.5-20 ppm are presented. It is shown that this new liquid membrane system, is able to remove boron from ground waters at their natural pH of 6-8 (without any chemical addition for pH adjustments). The removal efficiency is good when the process is upgraded to a hollow-fibre membrane contactor and approximately 45% boron can be removed in a single-stage contact. There are additional advantages of this new approach that includes reduced operational health and safety and environmental issues. The results reported here provide guidelines to the development of boron removal process using renewable, biodegradable, safe and cheap solvent system such as sunflower oil.

Polymer Electrolytes and their Application to Solar Cells and Separation Membranes (촉진수송 및 태양전지용 분리막)

  • 강용수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.03a
    • /
    • pp.13-35
    • /
    • 2004
  • Metal Complexes in Macromolecules Applications of Polymer Electrolyte Membranes Facilitated Transport in Solid State Roles of Electrolytes in Solar Cells - Electrolytes :ㆍI- and $I_3$-conductor ㆍelectron barrier or hole conductor ㆍelectrochemical redox reaction media ㆍinterfacial contactor for dye, $TiO_2$ and electrode ㆍmechanical separator (omitted)

  • PDF

Thends in Membrane Contactors (분리막 접촉기의 기술 동향)

  • Lee Kew-Ho;Kim Min-Joung;Sea Bongkuk;Park You-In;Lee Ki-Sub
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.187-197
    • /
    • 2005
  • A membrane contactor is a device that achieves liquid/liquid or gas/liquid mass transfer without dispersion of one phase within another. This is accomplished by passing the fluids on opposite sides of a microporous membrane. This approach offers a number of important advantages over conventional dispersed phase contactors, including absence of emulsions, no flooding at high flow rates, no unloading at low flow rates, and high interfacial area. This article provides a general review of membrane contactors, including operating principles and applications.

PEI Hollow Fiber Membranes Modified with Fluorinated Silica Nanoparticles for the Recovery of Biogas from Anaerobic Effluents (불화 실리카로 개질된 폴리에테르이미드 중공사막을 이용한 혐기성 유출수로부터 바이오가스 회수)

  • Yun, Kang Hee;Wongchitphimon, Sunee;Bae, Tae-hyun
    • Membrane Journal
    • /
    • v.30 no.5
    • /
    • pp.326-332
    • /
    • 2020
  • In this study, polymer-fluorinated silica composite hollow fiber membranes were fabricated and applied to a membrane contactor for the recovery of methane dissolved in the anaerobic effluent. To prepare the composite membranes, porous hollow fiber substrates were fabricated with Ultem®, a commercial polyetherimide (PEI). Subsequently, fluorinated silica particles were synthesized and coated on the surface via strong covalent bonding. Due to the high porosity, our membrane showed a CH4 flux of 8.25 × 10-5 ㎤ (STP)/㎠·s at the liquid velocity of 0.03 m/s which is much higher that that of commercial polypropylene membrane designed for degassing processes. This is attributed to our membrane's high porosity as well as a superior surface hydrophobicity (120~122°) resulted from the coating with fluorinated silica nanoparticles.

A Study on the Absorption of Carbon Dioxide using PVDF/Plasma Membrane Contactor (PVDF/플라즈마 막접촉기를 이용한 이산화탄소의 흡수에 관한 연구)

  • Choi, Seung-Hak;Gao, Tongzhai;Oh, Sae-Joong
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.161-169
    • /
    • 2005
  • Numerical simulation and experiments were carried out on the absorption of carbon dioxide using PVDF hollow-fiber membrane contactor. Water or monoethanolamine (MEA) aqueous soluton was used as absorbents. Simulation results showed that the concentration profile of carbon dioxide was less affected by the flow rate of MEA than that of water absorbent. The absorption rate and mass transfer coefficient of carbon dioxide increased as the concentration of MEA increased. The mass transfer coefficients obtained by experiments coincided with those obtained by numerical simulation and theoretical results for $CO_2-water$ system. However, for $CO_2-MEA$ system, the mass transfer coefficients obtained by experiments were lower than those obtained by simulation, while the simulation results agreed well with theoretical results. The durability of plasma-treated hollow fiber membranes was better than that of no plasma-treated ones.

Separation of Sulfur Dioxide by Circulatory Porous Polymer Membrane Contactor (순환식 고분자 분리막 접촉기를 이용한 이산화황 분리)

  • Lee, Yong-Taek;Jeon, Hyun-Soo;Ahn, Hyo-Seong;Song, In-Ho;Jeong, Heon-Kyu;Lee, Hyung-Keun
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.302-310
    • /
    • 2007
  • The effects of various system parameter on the absorption of sulfur dioxide into the absorbent liquid were investigated in a circulatory porous polymer membrane contactor. A feed gas and an absorbent used in the study were the gas mixture of air and $SO_2$ and the $Na_2SO_3$ aqueous solution, respectively. The separation of sulfur dioxide was measured in terms of the concentration of $Na_2SO_3$ absorbent, the concentration of sulfur dioxide, the feed flow rate, the absorbent velocity and the different membrane material. As the concentration of absorbent increased from 0.05 to 0.2 M, the removal efficiency increased from 74 to 100%. By increasing the concentration of sulfur dioxide from 700 to 2,500 ppm, the removal efficiency decreased from 100 to 75%. Also as the absorbent velocity increased from 2.5 to 15 mL/min, the removal efficiency increased from 85 to 100%. As the porosity of the membrane increased, the removal efficiency increased.