• 제목/요약/키워드: medium voltage

검색결과 425건 처리시간 0.023초

A Framework for Wide-area Monitoring of Tree-related High Impedance Faults in Medium-voltage Networks

  • Bahador, Nooshin;Matinfar, Hamid Reza;Namdari, Farhad
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Wide-area monitoring of tree-related high impedance fault (THIF) efficiently contributes to increase reliability of large-scaled network, since the failure to early location of them may results in critical lines tripping and consequently large blackouts. In the first place, this wide-area monitoring of THIF requires managing the placement of sensors across large power grid network according to THIF detection objective. For this purpose, current paper presents a framework in which sensors are distributed according to a predetermined risk map. The proposed risk map determines the possibility of THIF occurrence on every branch in a power network, based on electrical conductivity of trees and their positions to power lines which extracted from spectral data. The obtained possibility value can be considered as a weight coefficient assigned to each branch in sensor placement problem. The next step after sensors deployment is to on-line monitor based on moving data window. In this on-line process, the received data window is evaluated for obtaining a correlation between low frequency and high frequency components of signal. If obtained correlation follows a specified pattern, received signal is considered as a THIF. Thereafter, if several faulted section candidates are found by deployed sensors, the most likely location is chosen from the list of candidates based on predetermined THIF risk map.

분산제어를 이용한 고압인버터 시스템 (Medium Voltage Inverter System Using Decentralized Control)

  • 장한근;김효진;전재현;윤홍민;나승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.464-466
    • /
    • 2007
  • H-Bridge Multi-Level (HBML) 고압인버터는 저압의 반도체 소자를 사용하는 단상 H-Bridge 인버터로 구성 된 셀을 직렬로 연결함으로써 정현파에 가까운 고전압을 얻을 수 있고, 입 출력 고조파가 낮아서 필터가 필요 없는 토폴로지로 산업분야에서 사용이 확대되고 있다. 본 논문은 HBML 고압인버터의 마스터 제어기와 셀 제어기의 통신 하드웨어를 병렬로 구성하여서 하나의 전압지령 값과 Angle 값으로 셀에서 PWM을 구현 할 수 있는 분산제어 방식을 제안한다. 이 방식에서 셀 제어기가 전압, 전류, 주파수, 보호기능, 통신감시 정보 등 셀 제어의 대부분을 담당함으로써 마스터 제어기의 부담을 줄이고, 따라서 신호선의 개수를 줄일 수 있다. 또 통신하드웨어의 종단에 마스터 제어기를 연결만 하면 마스터제어기의 2중화가 가능하므로 사용하고 있던 마스터 제어기의 고장 발생 시에 대체하여 사용할 수 있으므로 시스템의 안정성 향상에 도움을 준다. 선간전압 33레벨로 구성된 HBML 고압인버터 시험을 통해 제안된 방식의 타당성과 신뢰성을 검증한다.

  • PDF

정극 활물질 LiMnO2 충.방전과 임피던스 특성 (The Impeditive Properties and Charge/Discharge of Positive Active Material $LiMnO_2$)

  • 위성동;김종옥;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.299-305
    • /
    • 2003
  • The battery industries have been developed to the implementation of lithium ion secondary cell from the cell of Ni/Cd and Ni/MH in the past to be asked of an age of high technology from low technology. Also in resent the polymeric cell to get a good high function with an age of new advanced information system is changed from the 21 century to the secondary batteries society. The properties of lithium secondary batteries have the high energy density, the long cycle time, the low self discharge area and the high active voltage. The wanted properties of secondary batteries for the motion of an apparatuses of industries of an high skill age have a small type trend of the energy density and it is become with a strong asking of the industrial society market about the storable medium of the convenience and new power energy. The electrochemical properties is researched for the cell to be synthesised and crystallized the positive active material LiMnO2 of the secondary cell at 9250C to get a new improved data of the electric discharge for that the capacitance of the LiMnO2 thin film that is improving and researching with the properties and a merit and demerit in the this kind of asking.

  • PDF

기능성 경사 재료의 적용을 통한 진공 인터럽터의 삼중점 전계 완화 (Reduction of the Electric Field Concentration at the Triple Junction of the Vacuum Interrupter by Using the Application of Functionally Graded Material)

  • 최승길;구치욱;주흥진
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.630-635
    • /
    • 2015
  • A vacuum Interrupter (VI), a core part that composes the breaking part of medium-voltage vacuum circuit breaker (VCB), has the excellent insulation performance and arc-extinguishing capability. $SF_6$ gas had been used for the external insulation of VIs since the dielectric strength of $SF_6$ gas is superior to that of other insulation gases. However, because of environmental problems related with global warming, a solid-insulated technology was recently researched. The functionally graded material (FGM), as changing spatially the distribution of the relative permittivity inside an insulator, can reduce the electric field stress at the specific region. Especially, the external insulation performance of the VI with the molded FGM insulator is greatly improved as compared with that of the existing VI or the VI with a new external shield. In this paper, the effectiveness of this FGM insulator is verified by the numerical simulation.

고압 전력선 통신을 위한 임피던스 측정과 정합 방안 연구 (Study on Impedance Measurement and Matching for Medium-Voltage Powerline Communications)

  • 유정훈;최승지;박영진;이원태;김관호;홍충선;이대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1981-1983
    • /
    • 2003
  • 본 연구에서는 고속전력선통신(PLC)을 위한 고압배전선의 임피던스 측정 방법을 소개한다. 현재 전세계적으로 고속 PLC를 위해서 1MHz${\sim}$30MHz대역을 사용하고 있다. 임피던스 특성을 실제 필드에서 측정하기 위해 본 연구에서는 휴대용 고압결합장치를 개발하였다. 임의의 고압 배전선에 일시적으로 결합할 수 있도록 고안된 고압결합장치로서 살아있는 전력선에 정전 없이 설치 가능하다. 이 장치는 고압용 커풀러(Coupler)와 60Hz 저주파를 차단하기 위한 드레인 코일(drain coil)로 구성되었다. 측정을 위해서는 벡터 회로망 분석기를 사용하였으며, 본 논문에서는 측정된 고압선 임피던스를 보여 주고 이 결과를 이용한 임피던스 정합 방법을 제시하였다.

  • PDF

An Electric-Field Coupled Power Transfer System with a Double-sided LC Network

  • Xie, Shi-Yun;Su, Yu-Gang;Zhou, Wei;Zhao, Yu-Ming;Dai, Xin
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.289-299
    • /
    • 2018
  • Electric-field coupled power transfer (ECPT) systems employ a high frequency electric field as an energy medium to transfer power wirelessly. Existing ECPT systems have made great progress in terms of increasing the transfer distance. However, the topologies of these systems are complex, and the transfer characteristics are very sensitive to variations in the circuit parameters. This paper proposes an ECPT system with a double-sided LC network, which employs a parallel LC network on the primary side and a series LC network on the secondary side. With the same transfer distance and output power, the proposed system is simpler and less sensitive than existing systems. The expression of the optimal driving voltage for the coupling structure and the characteristics of the LC networks are also analyzed, including the transfer efficiency, parameter sensitivity and total harmonic distortion. Then, a design method for the system parameters is provided according to these characteristics. Simulations and experiments have been carried out to verify the system properties and the design method.

25.8kV 25kA 열팽창분사식 가스차단기 개발에 관한 연구 (I) (A Study on the Development of 25.8kV 25kA Gas Circuit Breaker Using Thermal-Expansion Principle (I))

  • 송기동;박경엽;신영준;장기찬;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.160-164
    • /
    • 1995
  • In order to develop a medium voltage class gas circuit breaker by our own technology, we designed and manufactured the model interrupters using the hybrid arc extinguishing principle which adopts the thermal expansion principle in the large current region and the arc rotation principle by permanent magnet in the small current region. As the results of the first year research out of three years' research period, the main design parameters such as the volume of thermal expansion chamber, the distance between fixed contact and nozzle, the length of nozzle throat, the nozzle expansion angle and the magnitude of permanent magnet etc. have been determined. 4 types of model interrupters have been designed and manufactured considering the main design parameters. The 25kA short-circuit test and capacitive current breaking test have been performed for the model interrupters and the test results analyzed to improve the model interupters.

  • PDF

Thermo-electro-elastic nonlinear stability analysis of viscoelastic double-piezo nanoplates under magnetic field

  • Ebrahimi, Farzad;Hosseini, S. Hamed S.;Selvamani, Rajendran
    • Structural Engineering and Mechanics
    • /
    • 제73권5호
    • /
    • pp.565-584
    • /
    • 2020
  • The nonlinear thermo-electro-elastic buckling behavior of viscoelastic nanoplates under magnetic field is investigated based on nonlocal elasticity theory. Employing nonlinear strain-displacement relations, the geometrical nonlinearity is modeled while governing equations are derived through Hamilton's principle and they are solved applying semi-analytical generalized differential quadrature (GDQ) method. Eringen's nonlocal elasticity theory considers the effect of small size, which enables the present model to become effective in the analysis and design of nano-sensors and nano actuators. Based on Kelvin-Voigt model, the influence of the viscoelastic coefficient is also discussed. It is demonstrated that the GDQ method has high precision and computational efficiency in the buckling analysis of viscoelastic nanoplates. The good agreement between the results of this article and those available in literature validated the presented approach. The detailed mathematical derivations are presented and numerical investigations are performed while the emphasis is placed on investigating the effect of the several parameters such as electric voltage, small scale effects, elastomeric medium, magnetic field, temperature effects, the viscidity and aspect ratio of the nanoplate on its nonlinear buckling characteristics. It is explicitly shown that the thermo-electro-elastic nonlinear buckling behavior of viscoelastic nanoplates is significantly influenced by these effects. Numerical results are presented to serve as benchmarks for future analyses of viscoelastic nanoplates as fundamental elements in nanoelectromechanical systems.

An exact solution for buckling analysis of embedded piezo-electro-magnetically actuated nanoscale beams

  • Ebrahimi, Farzad;Barati, Mohammad Reza
    • Advances in nano research
    • /
    • 제4권2호
    • /
    • pp.65-84
    • /
    • 2016
  • This paper investigates the buckling behavior of shear deformable piezoelectric (FGP) nanoscale beams made of functionally graded (FG) materials embedded in Winkler-Pasternak elastic medium and subjected to an electro-magnetic field. Magneto-electro-elastic (MEE) properties of piezoelectric nanobeam are supposed to be graded continuously in the thickness direction based on power-law model. To consider the small size effects, Eringen's nonlocal elasticity theory is adopted. Employing Hamilton's principle, the nonlocal governing equations of the embedded piezoelectric nanobeams are obtained. A Navier-type analytical solution is applied to anticipate the accurate buckling response of the FGP nanobeams subjected to electro-magnetic fields. To demonstrate the influences of various parameters such as, magnetic potential, external electric voltage, power-law index, nonlocal parameter, elastic foundation and slenderness ratio on the critical buckling loads of the size-dependent MEE-FG nanobeams, several numerical results are provided. Due to the shortage of same results in the literature, it is expected that the results of the present study will be instrumental for design of size-dependent MEE-FG nanobeams.

Removal of Methylene blue from saline solutions by adsorption and electrodialysis

  • Lafi, Ridha;Mabrouk, Walid;Hafiane, Amor
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.139-148
    • /
    • 2019
  • In this study, the removal of MB from saline solutions was evaluated by two methods by adsorption and electrodialysis; the adsorption of the mixture dye/salt on dried orange peel waste (OPW) was studied in batch method. In this study the biosorption of cationic dye by OPW was investigated as a function of initial solution pH, and initial salt (sodium chloride) concentration. The maximal dye uptake at $pH{\geq}3.6$ in the absence and in the presence of salt and the dye uptake diminished considerably in the presence of increasing concentrations of salt up to 8 g/L. The Redlich Peterson and Langmuir were the most suitable adsorption models for describing the biosorption equilibrium data of the dye both individually and in salt containing medium. As well, this work deals with the electrodialysis application to remove the dye. Synthetic solutions were used for the investigation of the main operational factors affecting the treatment performance; such as applied voltage, pH, initial dye concentration and ionic strength. The experimental results for adsorption and electrodialysis confirmed the importance of electrostatic interactions on the dye. The electrodialysis process with standard ion exchange membranes enabled efficient desalination of cationic dye solutions; there are two main factors in fouling: electrostatic interaction between cations of dyes and the fixed charged groups of the CEM, and affinity interactions.