• Title/Summary/Keyword: medical equipment design

Search Result 143, Processing Time 0.025 seconds

Design and Implementation of Reception Systems for Non-Face-To-Face Medical Services (비대면 의료 서비스를 위한 접수시스템 설계 및 구현)

  • Baek, Yu-Jin;Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.975-980
    • /
    • 2021
  • As technology utilizing low-power short-range wireless communication is applied in conjunction with medical information as a development of the fourth industrial revolution, interest in medical information is increasing. As the age group of smart devices increases and becomes more common, related research such as linking mobile devices with various objects and equipment is continuously being conducted. In addition, interest in untact (non-face-to-face) is increasing due to the prevalence of Coronavirus Disease-19 (COVID-19), including various infectious diseases. As a result, it is a state that requires distance not only in social but also in life. In this study, using a low-power near-field wireless communication technology of beacons to create an IoT device by communicating with the web server of the medical information system was studied to make it easier to receive medical treatment during visits to medical institutions.

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

Characteristics of Design Parameters on the Regenerative Blower Used for Building Fuel Cell System (건물 연료전지용 재생블로어 설계변수 특성연구)

  • Jang, Choon-Man;Lee, Jong-Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.739-744
    • /
    • 2012
  • This paper describes the blower performance used for single-stage high pressure regenerative blower. The blower considered is widely applied to the field of a fuel cell system, a medical equipment and a sewage treatment plant. Flow rate and rotating frequency of a impeller of the blower are considered as design parameters for the proper operation of the blower. Three-dimensional Navier-Stokes equations are introduced to analyze the performance and internal flow of the blower. Relatively good agreement between experimental measurements and numerical simulation is obtained. Throughout a numerical simulation, it is found that small and stable vortical flow generated inside the blade passage is effective to increase pressure and efficiency of the blower. Large local recirculation flow having low velocity in the blade passage obstructs the generation of stable vortical flow, thus increases the pressure loss of the blower. Detailed flow field inside the blower is also analyzed and discussed.

Design, Fabrication and Characteristics of a MCA Valve (적층형 압전밸브의 설계, 제작 및 특성)

  • Chung, Gwiy-Sang;Kim, Jae-Min;Yoon, Suk-Jin;Jeong, Soon-Jong;Song, Jae-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.230-235
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 seem at a supplied voltage of 100 V with a 50% duty cycle, maximum non-linearity was 2.24% FS and leak rate was $3.03{\times}10^{-8}pa{\codt}m^{3}/cm^{2}$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.

Studies on Effective Fluid Monitoring Terminal design with the Use of location-based service (위치기반서비스를 활용한 효율적인 수액 모니터링 단말기 디자인에 관한 연구)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.421-426
    • /
    • 2016
  • Fluid is normally used so that certain drug can be administered to patients for certain period of time. There are many incidents in which patients or guardians need to call upon medical staff after estimating the time of fluid injection termination. In case fluid injection is terminated during certain period such as sleeping time or others, it may cause more fatigue for either patients or guardians. Also, it may lead to ineffective work as medical staff needs to monitor the quantity of fluid several times in order to check the time of fluid injection termination. Therefore, the purpose of this study is to propose LBS system combined of minimum equipment and active RFID to monitor the level of fluid in order to solve abovementioned problems. Also, it is expected to enhance the quality of medical service with service in which real-time monitoring of fluid quantity and patient location is conducted to provide accurate information to either patients, guardians, or medical staff(nurse) so that medical staff can locate and see patients at the time of fluid injection termination.

The Fabrication and Design of Driving Circuit for LCD panel using the high efficiency LED (고 효율 LED를 이용한 LCD 패널 구동회로의 설계 및 제작)

  • Ryu, Jang-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3146-3151
    • /
    • 2012
  • For using them as a optical source of inspections equipment for LCD panel, the design ofexcellent backlight system, brightness uniformity and high power and good protection against heat is essential.In this paper, backlight system which is built in the 45 inch side emitting LCD backlight by LED arraystructure and driving circuit were designed and developed. After that, their performances were measured. Itshowed the luminance from 3,000 to 25,000[$cd/m^2$], the mean value x:0.3144, y:0.3076 of x-y chromaticity,dimming range of 27~515[$cd/m^2$], free flicker noise in the 80kHz and black level of 0.7~0.1[$cd/m^2$], thermaltest of cooling system in 20,000[$cd/m^2$] over values.

Design and Implementation of IoT Terminal Equipment for Vessels using Thuraya Geo-stationary Orbit Satellite (Thuraya 정지궤도 위성을 이용한 선박용 IoT 단말 장치 설계 및 구현)

  • Jang, Won-Chang;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.67-72
    • /
    • 2020
  • Satellite communication is not used by many people like mobile communication, but it is a necessary technology for public service and communication services, such as providing the Internet in military, disaster, remote education and medical services, island areas, and infrastructure vulnerable areas. However, on ships and aircraft, mobile communications requiring base stations are either unavailable or restricted in their use. In this paper, we used a Raspberry Pi board as the terminal device to communicate network through satellite modem and PPP protocol, and implemented two-way data link using the text message of the modem to connect to the Thuraya geo-stationary orbit network. In addition, I/O devices were connected to the controller of the terminal equipment to design and implement an IoT device system for ships that can remotely access the system under control and control I/Os and transmit measured data through various sensors.

A Study on the Development of Protective Inner Wear for Lumbar Disc Disease Patients (Part I) -Analysis of Commercial Lumbar Pads and the Actual Wearing State of the Lumbar Pads- (허리디스크 환자를 위한 허리보호용 이너웨어 개발 연구(제1보) -시판 허리디스크 보조기 분석과 허리디스크 환자의 보조기 착용실태 조사-)

  • Kang, Hye-Jin;Jung, Myoung-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.3
    • /
    • pp.516-525
    • /
    • 2016
  • Lumbar discs are one of the first parts of the musculoskeletal system to age in the human body. Lumbar disc for females start to age at twenty years of age and completely age between fifty and sixty. The number of lumbar herniated intervertebral disc patients are increasing rapidly; however, studies on protective inner wear are insufficient. This study was conducted to develop protective inner wear equipment that retains an aesthetic appreciation of the body. The methods and procedures of this study are as follows. First, foreign and domestic lumbar pads were researched and analyzed by visiting medical shops and internet shopping malls that sell lumbar pads. Second, the survey was conducted on forty patients with disc disease in hospitals located in Seoul and surrounding suburbs. The following are the study results and observations. First, the lumbar pads selling on the market had a variety of designs, textiles, and fabrics. The result of the research was to develop additional inner protective equipment for lumbar herniated intervertebral disc patients. Second, the survey results of the forty patients with disc disease were that housewives were the most vulnerable. All patients had experience purchasing lumbar pads. The prevention of pain and stress were the most selected responses for the motivation to buy lumbar pads. Most individuals said that they used lumbar pads for less than 1 year. Dissatisfaction came from fabric, activity and design. 'Being uncomfortable to wear' was the most common complaint. 'Protection and how easy the clothes were to wear' were the most selected for the necessity of developments. The Inner wear shape was the most selected in shape. Except for six respondents, all favored the lumbar protective inner wear design.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF