• Title/Summary/Keyword: medical equipment design

Search Result 142, Processing Time 0.025 seconds

Optimal Design of Medical Bed Head Consol Considering the Strength Condition (의료용 베드 헤드 콘솔의 강도조건을 고려한 최적 설계)

  • Byon, Sung-Kwang;Choi, Ha-Young;Lee, Bong-Gu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.3
    • /
    • pp.8-14
    • /
    • 2016
  • Medical bed head consoles (BHC) are generally used to increase the efficiency of medical equipment and speed the medical treatment response time. The BHC design has been consistently improved including a movable shelf unit that is embedded to mount stably medical instruments on the lower part of the main console. The cost of a BHC can be reduced through design optimization to limit the overall weight. However, as the size of a head console might decrease due to design optimization, the BHC deflection could be increased. In this study, multi-objective optimal design was adopted to consider this BHC design problem. In order to reduce the cost of optimization planning, an approximate model was applied for the design optimization. In the context of approximate optimization, we used the response surface method and non-dominant sorting genetic algorithm developed from various fields. Multi-objective optimal solutions were also compared with a single objective optimal design.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on less than three hundred bed hospitals (종합병원 진단검사의학과 검사실의 시설 현황 조사 - 300 병상 미만 병원을 중심으로)

  • Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.15-23
    • /
    • 2019
  • Purpose: As the medical laboratories in general hospitals have made an efforts on quality management and employee health, they recognized the need of design guideline for clinical laboratory. As laboratories are prohibited to patients, their environments are becoming more congested and deteriorated as time goes by. So, this study investigates the current status of facility and equipment of laboratory medicine focusing on less than three hundred patient bed hospitals, and searches the improving matters. Methods: Questionnaires to technologist captains and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 18 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into followings. Clinical laboratory functions are all hematology, clinical chemistry, immunology, transfusion and urine microscopy, and except for three including microbiology for infection and bio safety level. Average man power of lab are 12.3 man including lab director and captain. Patient bed number, space area and total specimen numbers are not correlated with each other, but specimen numbers and employee number are correlated with. Work space distances are usually good, but exit distances are not adequate for escape owing to obstacles. Specimen delivery system by courier, test method by automatic analyzer, access floor for exposed plumbing and electricities are more practical. Open lab layed out in the center and lab support layed peripheral in space diagram. Lab space configuration by SD method showed that lab support area and employee support area are dissatisfied. Implications: Specialized hospital and yearly total specimen numbers are related to the space area and organization for laboratory planning and design.

Class E Power Amplifiers using High-Q Inductors for Loosely Coupled Wireless Power Transfer System

  • Yang, Jong-Ryul;Kim, Jinwook;Park, Young-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.569-575
    • /
    • 2014
  • A highly efficient class E power amplifier is demonstrated for application to wireless power transfer system. The amplifier is designed with an L-type matching at the output for harmonic rejection and output matching. The power loss and the effect of each component in the amplifier with the matching circuit are analyzed with the current ratio transmitted to the output load. Inductors with a quality factor of more than 120 are used in a dc feed and the matching circuit to improve transmission efficiency. The single-ended amplifier with 20 V supply voltage shows 7.7 W output power and 90.8% power added efficiency at 6.78 MHz. The wireless power transfer (WPT) system with the amplifier shows 5.4 W transmitted power and 82.3% overall efficiency. The analysis and measurements show that high-Q inductors are required for the amplifier design to realize highly efficient WPT system.

Design of the Medical Thermal Array Printer Module Based on Microcontroller (마이크로 콘트롤러를 이용한 의료용 열전식 프린터 모듈의 개발에 관한 연구)

  • Lee, Myoungho;Kong, Inwook;Kwon, Hyukje
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.129-138
    • /
    • 1996
  • This paper describes design techniques of general purpose thermal array printer, especially easily applicable to medical measurement equipment. The'general'means that the proposed thermal array printer can be applied to not only medical field but other industrial field by establishing the eligible protocol. The thermal array printer is composed of i)MPU and its peripherals ii)printer head control, iii)diverse protection circuits, and iv)serial communication. In this paper the performance of the proposed thermal array printer was evaluated by applying to an 3 channel electrocardiogram recorder. The propped system can support'Hangul'text as well as alphanumeric characters and any bitmap image.

  • PDF

A Study on the Development of Wheelchair Safety Clothing for the Disabled Elderly (거동 불편 노인을 위한 휠체어 안전복 개발)

  • Yun, Mi-Yeong;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.4
    • /
    • pp.642-652
    • /
    • 2010
  • This study examines the inconveniences and problems of established safety-equipment by investigating the actual conditions for elderly people who use welfare services such as wheel chairs provided by care institutions. Suggestions will be made on how to improve the function and convenience of use to suit the needs of the elderly and how to create beautiful wheel chair safety-wear. Medical treatment helpers for the elderly were surveyed about the wearing conditions of wheel chair safety equipment. The present wheel chair safety equipment was shown to be aesthetically unpleasant; in addition, feelings of restriction and unpleasantness were noted (concerning the wearing of the equipment). In addition, there was no feeling of fixed stability. The wheel chair safety-wear that has been designed reflects the inconveniences and problems of current wheel chair safety equipment in material, design, and patterns along with the results of those surveys. Both objective and subjective tests compared the manufactured safety-wear with current equipment. According to the results, the new safety-wear is superior than existing ones.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

A new gradient coil design technique for open magnetic resonance imaging systems (개방형 자기공명영상시스템용 경사자계코일의 새로운 설계기법)

  • Lee, Soo-Yeol;Park, Bu-Sik;Yi, Jeong-Han;Yi, Wan
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.1
    • /
    • pp.72-79
    • /
    • 1997
  • Most open magnetic resonance imaging systems have used the planar gradient coils whose inductances were minimized through the magnetic energy minimization procedure in the spatial frequency domain. Though the planar gradient coils have smaller inductance than conventional gradient coils, the planar gradient coils often suffer from their poor magnetic field linearity. Scaling the spatial frequencies of the current density function designed by the magnetic energy minimization, magnetic field linearity of the planar gradient coils can be greatly improved with small sacrifice of gradient coil inductance. We have found that the figure of merit of the planar gradient coils, defined by the gradient strength divided by the linearity error and the inductance, can be improved by proposed technique.

  • PDF

Design for a Medical Devices Safety Information Reporting System for the Hospitals (의료기기 안전성 정보 원내 보고 시스템 설계)

  • Jang, Hye Jung;Choi, Young Deuk;Kim, Nam Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.140-147
    • /
    • 2015
  • In this study, medical devices safety information reporting system was designed to manage medical devices for the efficient management of in-hospital adverse events. The current management of medical device adverse event reporting regulations and the legal status of the system and procedures for identifying the system were reviewed. MSF/CD(Microsoft Solution Framework/Component Design) was applied to the system design. Through this study, we can understand medical devices management including the notice provisions of the Ministry of Food and Drug Safety for medical devices safety information reporting. We also expect this study will help to improve patient safety and the effective management of medical equipment, and contribute to activating medical devices safety information reporting.

Design of Automated Negotiation Scheduling System for Medical Services (의료서비스를 위한 자동협상 스케줄링 시스템 설계)

  • Kim, Kyoung-Hwan
    • Journal of Internet Computing and Services
    • /
    • v.9 no.3
    • /
    • pp.59-67
    • /
    • 2008
  • New system solves scheduling problem in medical services. The existing scheduling system by FCFS is for a hospital but new system expresses the condition of a hospital and the profit of separate system's parties by the automated negotiation. This system expresses user preference time as a priority number and is designed that the schedule is changed according to the priority number with a negotiation strategy for a patient. And a hospital makes a schedule according to the policy. The system supports customer satisfaction in medical services by considering not only equipment efficiency but also the patent waiting time unlike the existing system considering the idle time for a equipment.

  • PDF

Progress on Proton Therapy Facility Project in National Cancer Center, Korea

  • Kim, Jong-Won;Park, Sung-Yong;Park, Dahl;Kim, Dae-Yong;Shin, Kyung-Hwan;Cho, Kwan-Ho
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.180-182
    • /
    • 2002
  • A Proton Therapy Center was established this year in National Cancer Center, Korea. We chose IBA of Belgium as the vendor of the equipment package. A 230 MeV fixed-energy cyclotron will deliver proton beams into two gantry rooms, one horizontal beam room, and one experimental station. The building for the equipment is currently under design with a special emphasis on radiation shielding. Installation of equipments is expected to begin in September next year starting with the first gantry, and the acceptance test will be performed about a year later. To generate therapeutic radiation fields the wobbling method will be a main treatment mode for the first gantry. A pencil beam scanning system on the other hand will be equipped for the second gantry relying on the availability at the time of installation. The beam scanning with intensity modulation adapted will be a most advanced form in radiation therapy known as IMPT. Some details on the project progress, scope of the system, and design of building are described.

  • PDF