• Title/Summary/Keyword: mechanical recovery

Search Result 854, Processing Time 0.027 seconds

THE DEVELOPMENT OF A NEW NO-CONTACT METHOD TO MEASURE THE MECHANICAL PROPERTIES OF SKIN: NEW AGE-RELATED PARAMETERS

  • Tsutomu Fujimura;Osamu Osanai;Shigeru Moriwaki;Syuichi Akazaki;Kim, ihiko-Hori;Yoshinori Takema
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.529-543
    • /
    • 2003
  • Real-time measurements of skin movement induced by air blown on the surface was measured with time. We investigated age-related changes in displacement of the skin surface on the face or the inner upper arm caused by air on 98 Japanese women volunteers aged from 10 to 70 years old. The maximum distance (the denting state) that the skin moved reached 2-5 mm within 10-15 msec on the cheek skin. After that, the skin generally recovered to the original state within 40-50 msec. The maximum speed of movement was 0.5 m/sec and the recovery speed was about 0.25 m/sec on the cheek skin. Significant changes with age were not observed in the denting state, but a significant correlation with age was observed in the recovery state. For example, the maximum recovery speed decreased significantly with age (p=-0.568, p<0.001) and the time required for recovery increased significantly with age (p=0.561, p<0.001). Although the inner upper arm also showed similar results to a cheek, a few parameters were different. This apparatus is a more practical macroscopic system for evaluating skin mechanical properties without contact. This apparatus is effective not only for measuring the mechanical properties of facial skin but also of body skin, such as swelling or sagging of body parts.

  • PDF

A Study on Pneumatic Transport of Abrasive (연소재의 기력수송 특성 연구)

  • Baek, Jae-Jin;Yun, Won-Jun;Lee, Chae-Seok;Chung, Mong-Ku;Shin, Sang-Ryong;Kwon, Hyeog-Jun;Lee, Byung-Hun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1442-1447
    • /
    • 2004
  • A significant amount of labor hour is being spent for clean up spent abrasives after blasting. So, for improving the efficiency of abrasive(grit) recovery process which acts as the neck of a battle in preceding coating stage, it was established the theoretical background for pneumatic transport technology in the abrasive recovery system as well as experimentally evaluated the effect of design parameters such as flow pattern, saltation velocity and pressure drop on the efficiency of the abrasive recovery system. And, by optimizing the operating parameter such as the length and diameter of suction hose, specification of recovery device, recovery mouth and hose connection method, a method which can dramatical1y increase the efficiency of abrasive recovery system, is derived.

  • PDF

Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems (가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석)

  • 김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.

Evaluation of Separation on the Copper Recovery from Jelly filled type Cable (젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가)

  • Min, Dal-Ki;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.

The characteristics of static pressure recovery in a conical diffuser with a swirling flow (선회류 유입에 대한 원추디퓨저의 정압회복 특성)

  • Jeong, Hyo-Min;Jeong, Han-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.7
    • /
    • pp.937-945
    • /
    • 1998
  • The purpose of this paper is to investigate the relationship between pressure recovery and turbulent characteristic value of velocity and pressure, in the case where a swirling flow streams into a conical diffuser. The results of both measurements of the wall pressure fluctuation and velocity fluctuation revealed them to role the large part of the total pressure loss of the flow. The cause of the fluctuation of flow was showed to be the flow separation at the inlet of diffuser at low intensity of swirl, but the flow of diffuser center was instable at high intensity of swirl. The static pressure recovery depends strongly on the magnitude of the turbulent energy in the diffuser, and that this magnitude of the turbulent energy varies as the intensity of swirl at the diffuser inlet.

4절점 응축 셸 요소를 이용한 복합재 적층 구조물의 전단응력 예측

  • Choe, Nu-Ri;Lee, Byeong-Chae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2292-2301
    • /
    • 2000
  • We propose an accurate and efficient estimation method of transverse shear stresses for analysis and design of laminated composite structures by 4-node quadrilateral degenerated shell elements. To get proper distributions of transverse shear stresses in each layer, we use 3-dimensional equilibrium equations instead of constitutive equations with shear correction factors which vary diversely according to the shapes of shell sections. Three dimensional equilibrium equations are integrated through the thickness direction with complete polynomial membrane stress fields, which are recovered by REP (Recovery by Equilibrium in Patches) recovery method. The 4-node quadrilateral degenerated shell element used in this paper has drilling degrees of freedom and shear stresses derived from assumed strain fields that are set up at natural coordinate systems. The numerical results demonstrate that the proposed estimation method attains reasonable accuracy and efficiency compared with other methods and FE analysis using 4-node degenerated shell elements.

A Study on the Calculation Method of VOCs Emissions Using Equation of State in the Gas Station Tank (상태방정식을 이용한 주유소 탱크에서의 유증기 배출량 산정법에 관한 연구)

  • Park, Taejoon;Oh, Wheesung;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.42-48
    • /
    • 2015
  • This study was investigated the estimation of VOCs (Volatile Organic Compounds) emission from a gas station tank. To improve the atmosphere environmental quality near the gas station, the installation of vapor recovery system has been expanded recently. Therefore, it was necessary to calculate VOCs emissions from the gas station tank with vapor recovery systems for evaluation of their performance. The VOCs emissions are difficult to measure directly because of various sources and irregularly emission by pressure rise. In this study, VOCs emissions were estimated by simple calculation based on the equation of state for measured pressure, temperature and volume of a gasoline tank at a gas station. The result confirmed that the present national emission factor did not have significant discrepancy with the calculated value.

Comparison of Mechanical Allodynia and Recovery of Locomotion and Bladder Function by Different Parameters of Low Thoracic Spinal Contusion Injury in Rats

  • Carter, Michael W.;Johnson, Kathia M.;Lee, Jun Yeon;Hulsebosch, Claire E.;Gwak, Young Seob
    • The Korean Journal of Pain
    • /
    • v.29 no.2
    • /
    • pp.86-95
    • /
    • 2016
  • Background: The present study was designed to examine the functional recovery following spinal cord injury (SCI) by adjusting the parameters of impact force and dwell-time using the Infinite Horizon (IH) impactor device. Methods: Sprague-Dawley rats (225-240 g) were divided into eight injury groups based on force of injury (Kdyn) and dwell time (seconds), indicated as Force-Dwell time: 150-4, 150-3, 150-2, 150-1, 150-0, 200-0, 90-2 and sham controls, respectively. Results: After T10 SCI, higher injury force produced greater spinal cord displacement (P < 0.05) and showed a significant correlation (r = 0.813) between the displacement and the force (P < 0.05). In neuropathic pain-like behavior, the percent of paw withdrawals scores in the hindpaw for the 150-4, 150-3, 150-2, 150-1 and the 200-0 injury groups were significantly lowered compared with sham controls (P < 0.05). The recovery of locomotion had a significant within-subjects effect of time (P < 0.05) and the 150-0 group had increased recovery compared to other groups (P < 0.05). In addition, the 200-0 and the 90-2 recovered significantly better than all the 150 kdyn impact groups that included a dwell-time (P < 0.05). In recovery of spontaneous bladder function, the 150-4 injury group took significantly longer recovery time whereas the 150-0 and the 90-2 groups had the shortest recovery times. Conclusions: The present study demonstrates SCI parameters optimize development of mechanical allodynia and other pathological outcomes.

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

Effect of treatment temperature on mechanical properties of silk textiles made with silk/polyurethane core-spun yarn

  • Bae, Yeon Su;Um, In Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.33 no.2
    • /
    • pp.108-112
    • /
    • 2016
  • Silk has been used extensively in textile applications because of its good luster and feel. However, the low elongation and elastic recovery of silk has limited its use in a wider variety of textile applications. In this study, silk textile samples were made with a highly twisted silk/polyurethane core-spun yarn. They were immersed in water and dried at different temperatures, and the effect of treatment temperature on the mechanical properties of the silk textile was examined. It was found that the water temperature strongly affected the morphology and mechanical properties of the silk textile, whereas the drying temperature did not. As the water temperature was increased, the weft silk yarn became tangled and the interval between warp yarns decreased, resulting in shrinkage of the silk textile. When the silk textile was immersed in water at high temperature (i.e., $100^{\circ}C$), the elongation of the textile increased eight-fold as compared to an untreated silk textile. The maximum elastic recovery ratio of the silk textile was 96.7%.