• Title/Summary/Keyword: measuring impedance

Search Result 322, Processing Time 0.026 seconds

The Study on Improvement of Audio Noise When 900MHz GSM Cellular Phone Built in HPC(Handheld PC) (GSM 모듈을 탑재한 HPC(Handheld PC)에서의 오디오 노이즈 개선에 관한 연구)

  • 박희봉;장복현;황금찬;박용서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1169-1178
    • /
    • 1999
  • In this paper, the method to improve audio noise when GMS(Global System of Mobile Communication) is built in HPC(Handheld PC)is provided. The biggest problem with quality of audio is improved by connecting GSM module with wire to the widest erea near by HPC Power Ground to reduce impedance difference, and designing amplifier and earpiece, Result of measurement is satisfied with GSM Acoustic Standard. Standard of GSM Audio is declared in GSM 11.10 ETS 300 607-1. Measuring items corresponds to that standard and B&K Type 6712 is used for measurement. The list of measurement presented in this paper is Sending Sensitivity Frequency Response and SLR, Sending Loudness Rating( SLR level), Receiving Sensitivity Loudness Rating(RLR level), Talker Sidetone(STMR), Stability margin, and Echo Loss(ERL)

  • PDF

On the Design of High Order Transformer Circuit Using the Genetic Algorithm and Its Application to the Wheeler Cap Measurement (유전자 알고리즘을 사용한 안테나 고차 변압 회로 구성과 변압 회로를 사용한 Wheeler Cap 효율 측정법)

  • Cho Chi-Hyun;Choo Ho-Sung;Park Ik-Mo;Kang Jin-Seob
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.753-759
    • /
    • 2006
  • Generally, the Wheeler cap method is used to measure the efficiency of small antennas. This method often gives an unreliable efficiency when the antenna has a complicated operating principle. However, if the high-order circuit model which more closely represents the input impedance of the antenna is used in Wheeler cap method, then more accurate efficiency can be achieved. In this paper, we propose a novel method that can build the high-order circuit model using transformer circuits with the genetic algorithm(GA). To efficiently reduce the searching space in the GA and improve the convergence of the GA process, we suggest a novel scheme that finds appropriate initial values. Finally we verify the proposed method by measuring the efficiency of some passive RFID tag antennas.

A Study on the Improvement for a Defect Diagnosis of Track Circuit on HSL (고속선 궤도회로 결함진단을 위한 개선방안 연구)

  • Park, Ki-Bum;Lee, Tae-Hoon;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1656-1664
    • /
    • 2007
  • This paper introduces a study of improvement for a defect diagnosis of the UM71C track circuit using on HSL. The track circuit on HSL has long operation section. Therefore, when the worker maintain, many times and efforts are spent. So, periodically, we have operated a inspection car. However, we don't know exactly the state changed of the inspection data when track circuit has defect. Actually, We fixed a sample area within operation section on HSL and performed the simulations for short circuit current that is reflected characteristic impedance and propagation factor. We compared the measuring data with the result of the simulation. Using verified simulation program, we estimated inspection data as the malfunction number and the change of capacity of compensation capacitor. These study need to secure of the safety as the train operation. Also, It needs to make a criteria of analysis for the maintenance through comparison simulation data and inspection data.

  • PDF

Synthesisand Electrochemical Behaviors of Hybrid Carbon (ACF/Graphene) as Supports by Microwaves-irradiation Method for Polymer Exchange Membrane Fuel Cells (PEMFC) (마이크로웨이브를 이용한 고분자 전해질 연료전지용 복합 탄소 촉매 지지체 (ACF/Graphene)의 합성과 전기화학적 거동)

  • Cho, Yongil;Jeon, Yukwon;Park, Dae-Hwan;Juon, So-Me;Kim, Tae-Eon;Oh, Kyeongseok;Shul, Yong-Gun
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.2
    • /
    • pp.142-149
    • /
    • 2013
  • Carbon materials are mainly used as catalyst supports for polymer exchange membrane fuel cell (PEMFC). Catalyst supports are required specific characteristics of the carbon materials, such as large surface area and high electrical conductivity. Attempted were to improve electrical conductivity and to maintain high surface area of carbon materials using a microwave treatment. Microwave treatment, as a relatively new technique, takes short reaction time and reduce the consumption of the gases used for carbon treatment compared to a traditional heat treatment. Hybrid carbon (ACF/Graphene) as catalyst supports by microwave-irradiation method for PEMFC increase the cell performance because of increased electrical conductivity resulting in triple-phase contact and reduced the interfacial resistance. Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X-Ray Diffraction (XRD) were employed to analyze carbon materials. The performance of microwave-treated carbon materials was evaluated by measuring current-voltage (I-V) characteristics and electrode impedance.

Thermoacoustic Refrigerating System, Part II : Implementation and Experiment (열음향 냉장시스템 (II) : 제작 및 실험)

  • Hah, Zae-Gyoo;Ahn, Chul-Yong;Sung, Keong-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.13-20
    • /
    • 1995
  • In this paper, the thermoacoustic refrigerating system was implemented and its operation was experimentally verified. The system is composed of several parts ,4 inch midrange speaker, speaker housing, chamber, stack housing, stack of plates, heat exchangers, thin pipe and cavity. The system is filled with He gas at 10 bar and contains T-type thermocouples and condenser microphone for measuring the temperature and pressure inside, respectively. In addition, cooling water is used for protecting speaker from thermal destruction and cooling down the hot heat exchanger. For the experimental verification of the implemented refigerating system, electrical impedance and resonance characteristics were measured. The results showed that it was most efficient to drive the system at 340 Hz. When operated at 340 Hz, $30^\circ{C}$ environments and 50 electical watts, the temperature of the cold region decreased by $16^\circ{C}$. The dissatisfaction mainly comes from the incomplete thermal insulation of the cold region. We also pointed out some guidelines to improve the performance for later study.

  • PDF

Effect of Deposition Parameter on Ionic Conductivity of RF Magnetron Sputtered Li$_2$O-B$_2$O$_3$-SiO$_2$ Solid Electroiyte Films (RF 마그네트론 스퍼터링법으로 증착된 Li$_2$O-B$_2$O$_3$-SiO$_2$ 계 비정질 박막 고체전해질의 증착변수에 따른 이온전도 특성에 관한 연구)

  • 노남석;권혁상
    • Journal of Surface Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.65-73
    • /
    • 1994
  • Effects of deposition parameter on the ionic conductivity and structural change of the Lithium borosili-cate solid electrolyte films, prepared by rf sputtering using 7$LI_2O-3B_2O_3-1SiO_2$ single phase target and also a mosaic target enriched with $LI_2O$, were analyzed by measuring AC impedance and IR absorption spectra for the films. Thed solid electrolyte film deposited from the single phase target exhibited very low ionic conductivi-ty of $10^{-10}{\Omega}^{-1}cm{-1}$ at room temperature, a result of low $Li^+$ ion content(7.52 at%) in the film. The $Li^+$ con-ductivity for the films deposited from the mosaic target, however, significantly increased to $10^{-7}{\Omega}^{-1}cm{-1}$ due to both an increased $Li^+$content (14.75 at %) and a structural change of the films. The increased ionic conduc-tivity of the film appears to be associated with an easiness of ionic mobility by structural change of glassy film from a some close packed network structure to a open one. These structural changes of film were found to be closely related to the increase in the peak intensity at~$960cm^{-1}$ of IR absorption spectra for the glassy films. With increasing either argon pressure from 3 to 21 mtorr or rf power from 2 to 3 W/$cm^2$, the $Li^+$ conduc-tivity for the films significantly increased to an order of $10^{-6}{\Omega}^{-1}cm{-1}$ due to an increase in openness of film structure, as confirmed by both an increase in the IR absorption peak intensity at ~$960cm^{-1}$ and a resultant reduction of activation energy for mobility of $Li^+$ ion.

  • PDF

Assessment of Incipient Decay of Radiata Pine Wood Using Stress-wave Technique in the Transverse Direction (횡단방향(橫斷方向) 응력파(應力波) 방법(方法)에 의(依)한 라디에타소나무의 초기부후(初期腐朽) 평가(評價))

  • Kim, Gyu-Hyeok;Jee, Woo-Guen;Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.18-27
    • /
    • 1996
  • The feasibility of using stress-wave technique in the transverse direction for the assessment of early stages of decay was investigated using compression test specimens having different annual ring orientations subjected to decay by Tyromyces palustris for various time intervals. Decay detection, quantitative assessment of decay, and the prediction of residual strength of decayed wood with less than five percent weight loss can be feasible using stress-wave parameters (wave velocity, wave impedance, and stress-wave elasticity) and their percent reduction due to decay, measured by stress-wave technique in the transverse direction. The use of stress-wave technique in the transverse direction for the application of this technique to structural members in service is desirable, when considering the easiness of attachment of accelerometers of stress-wave measuring device on the surface of members and also accurate detection of localized decayed areas. In stress-wave technique in the transverse direction, stress-wave parameters measured were different according to the angles between wave propagation path and annual ring, due to the anisotropy of wood structure. Therefore, it is recommended to use percent reduction in stress-wave parameters instead of stress-wave parameters. This evaluation method using percent reduction in stress-wave parameters is ideal when it is impossible to observe annual ring orientation on the transverse surface of wood.

  • PDF

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

Secondary Indirect Constant Voltage Control Technique for Hybrid Solid State Transformer using Primary Side Information (하이브리드 반도체 변압기의 1차측 정보를 이용한 2차측 간접 정전압 제어 기법)

  • Lee, Taeyeong;Yun, Chun-Gi;Cho, Younghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.420-423
    • /
    • 2020
  • This study proposes an indirect constant voltage control algorithm for hybrid solid-state transformers (HSSTs) by using primary side information. Considering the structure of HSSTs, measuring voltage and current information on the primary side of a transformer is necessary to control the converter and inverter of the power converter. The secondary side output voltage is measured to apply the conventional secondary side constant voltage control algorithm, and thus, the digital control board requires the same rated insulation voltage as that of the transformer. To solve this problem, the secondary voltage of the transformer obtained from the tap voltage is used. Moreover, output voltage decreases as load increases because the proposed indirect constant voltage control scheme does not consider the cable impedance between the secondary output terminal and the load. This study also proposes a technique for compensating the secondary output voltage by using the primary current of the transformer and the resistance value of the cable. An experiment is conducted using a scale-down HSST prototype consisting of a 660 V/220 V tap transformer. The problem of the proposed indirect constant voltage control strategy and the improvement effect due to the application of the compensation method are compared using the derived experimental results.

Effects of Shut-down Process on Degradation of Polymer Electrolyte Membrane Fuel Cells I. Effects of Hydrogen Removal on the Degradation (운전 정지 시 보관방법이 고분자 전해질 연료전지의 열화에 미치는 영향 I. 잔류 수소 제거 방법의 영향)

  • Lim, Sang-Jin;Cho, Eun-Ae;Lee, Sang-Yeop;Kim, Hyoung-Juhn;Lim, Tae-Hoon;Lee, Kwan-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.3
    • /
    • pp.118-123
    • /
    • 2006
  • Degradation of polymer electrolyte membrane fuel cell (PEMFC) that is facilitated by on/off cycles is one of the most important issues for commercialization of fuel cell vehicles. When a PEMFC stack is shut down, residual hydrogen and induce high voltage equivalent to open circuit voltage to the cathode side that might cause sintering of Pt catalyst and facilitate formation of hydrogen peroxide at the anode side that might decompose $Nafionc\'{A}$ membrane. In this study, degradation of PEMFC exposed to repetitive on/off cycles was investigated by measuring i-V characteristics, ac impedance, cyclic voltammograms, gas leak, cross-sectional SEM images, and TEM images. To prevent degradation of PEMFC caused by the residual gases, hydrogen was removed from anode gas channel by gas-purging and by using a dummy resistance, that were found to be a very effective method.