• Title/Summary/Keyword: measuring impedance

Search Result 322, Processing Time 0.029 seconds

Brightness Property by Applied Frequency for External Electrode Fluorescent Lamp (EEFL) (External Electrode Fluorescent Lamp (EEFL)의 입력 주파수에 따른 휘도특성)

  • Lee, Seonh-Jin;Yang, Jong-Kyong;Choi, Yong-Sung;Lee, Sang-Hern;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.223-225
    • /
    • 2005
  • An external electrode fluorescent lamps (EEFLs) have the advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Studies on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, an EEFL presented the possibility of using it as a light source for backlights. However, because an EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verifies the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examines the relationship between the change in the EEFL frequency and brightness by measuring the optical characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

Luminance Properties and Electrical Properties by Applied Frequency of External Electrode Fluorescent Lamp(EEFL) (EEFL의 주파수 변화에 따른 전기적 특성과 휘도특성)

  • Lee, Seong-Jin;Lee, Jong-Chan;Park, Noh-Joon;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.355-360
    • /
    • 2007
  • The recent TFT-LCD Trend that is done large size gradually. As size of monitor great, though problem happens, it is that consumer's request which it makes monitor combined TV function. Monitor and TV are no difference externally greatly, but define difference happens as for backlight. An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high Luminance using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and Luminance by measuring the optical characteristics.

Design of a composite diagnostic DC test apparatus for high voltage power cable (고압전력케이블 현장진단시험용 종합 직류시험설비의 검토)

  • Ryoo, Hee-Suk;Kang, Dong-Sik;Sim, Jong-Tae;Lee, Ho-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF

Optical Characteristics of EEFL (External Electrode Fluorescence Lamp) for Large Size BLU (대화면 BLU용 EEFL의 광학적 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.74-76
    • /
    • 2006
  • An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the ear1y stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high brightness using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significant1y affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell's electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and brightness by measuring the optical characteristics. In addition, the characteristics of the transformation of energy orbits were verified by investigating the characteristics of the wavelength according to the change in frequency through the OES.

  • PDF

Nafion-Sulfonated Poly(arylene ether sulfone) Composite Membrane for Direct Methanol Fuel Cell

  • Choi Jisu;Kim II Tae;Kim Sung Chul;Hong Young Taik
    • Macromolecular Research
    • /
    • v.13 no.6
    • /
    • pp.514-520
    • /
    • 2005
  • Composite membranes of Nafion and sulfonated poly(arylene ether sulfone) were prepared. Sulfonated poly(arylene ether sulfone)s with different degrees of sulfonation were blended with Nafion to reduce the methanol crossover. The morphology, proton conductivity and methanol permeability of the resulting composite membranes were investigated by SEM, EDAX, AC impedance spectroscopy and permeability measuring instrument. The cross­sections of the composite membranes showed a phase separated morphology. The morphology and phase separation mechanism could be controlled by varying the blend ratio and the degree of sulfonation of poly(arylene ether sulfone). These complex morphologies can be applied for reducing methanol crossover. The methanol permeability and proton conductivity of the composite membranes were lower than those of Nafion 117 membrane since the development of an ionic pathway in the blend membrane was more difficult than that in Nafion itself.

Transport Properties of Polymer Blend Membranes of Sulfonated and Nonsulfonated Polysulfones for Direct Methanol Fuel Cell Application

  • Kim, Dong-Hwee;Kim, Sung-Chul
    • Macromolecular Research
    • /
    • v.16 no.5
    • /
    • pp.457-466
    • /
    • 2008
  • The relation between the phase separated morphologies and their transport properties in the polymer blend membrane for direct methanol fuel cell application was studied. In order to enhance the proton conductivity and reduce the methanol crossover, sulfonated poly(arylene ether sulfone) copolymer, with a sulfonation of 60 mol% (sPAES-60), was blended with nonsulfonated poly(ether sulfone) copolymer (RH-2000, Solvay). Various morphologies were obtained by varying the drying condition and the concentration of the casting solution (10, 15, 20 wt%). The transport properties of proton and methanol molecule through the polymer blend membranes were studied according to the absorbed water. AC impedance spectroscopy was used to measure the proton conductivity and a liquid permeability measuring instrument was designed to measure the methanol permeability. The state of water in the blend membranes was confirmed by differential scanning calorimetry and was used to correlate the morphology of the membrane with the membrane transport properties.

Development of UWB Sinuous Antenna with Dielectric Lens for 3~6 GHz Band Application (유전체 렌즈를 가진 3~6GHz대용 UWB 시뉴어스 안테나 개발)

  • Lee, Dong Real
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.239-244
    • /
    • 2015
  • Recently, Impulse radars using UWB technologies are widely use for measuring distance, or for transmitting uncompressed high resolution videos. However, since the UWB band spans over octave bands, it is not easy to design such a system. Wide band impedance matching is required for antennas and other RF area. In this study, we designed and fabricated sinuous antenna for 3~6 GHz octave band application. We also designed and attached a dielectric lens to improved the directional gain of the antenna. The gain of the antenna was 6~10 dBi. The dielectric lens attached sinuous antenna was used to transmit HD video data. The maximum reach distance was 90 meter with 10mW power.

Cancelation of Baseline Wandering of Electroglottograph Signal using Empirical Mode Decomposition (경험적 모드 재구성 방법을 이용한 성문파형 신호의 기계선 변동 제거)

  • Jang, Seung-Jin;Kim, Hyo-Min;Park, Young-Cheol;Choi, Hong-Shik;Yoon, Young-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.475-476
    • /
    • 2007
  • Electroglottography (EGG) is a technique used to register laryngeal behavior indirectly by a measuring the change in electrical impedance across the throat during speaking. However, EGG waveform is affected by laryngeal muscles which fluctuate the vocal cords, and which result in baseline wander. It is required to reduce baseline wander in EGG waveform, because EGG waveform is used for input signal of nonlinear speech synthesizer in next chapter. In vocal cords, the abduction-adduction of glottis is mainly controlled by the posterior cricoarytenoid (abductor) and interarytenoid (adductor) muscles respectively. Empirical Mode Decomposition method was adopted in cancellation of EGG waveform baseline wandering, and showd better performance than that of high pass filter with 500 order.

  • PDF

A Internal Signal Modeling for a Defect Diagnosis of Track Circuit on HSL (고속선 궤도회로 결함진단을 위한 내부 모델링)

  • Park, Ki-Bum;Lee, Tae-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.779-785
    • /
    • 2006
  • This paper introduces a result of internal signal modeling for a defect diagnosis of the UM-71C track circuit using on HSL. Actually, We fixed a sample area within operating section on HSL and performed the simulations for short circuit current that is reflected characteristic impedance and propagation factor. We compared the measuring data with the result of the simulation. These modeling can be used as the basic data for secure of the safety. Also, It need to make a criteria of analysis for the maintenance through comparison simulation data and inspection data.

  • PDF

Effective Harmonic Diagnose Tool for Power Quality Problems (전기품질개선을 위한 효율적인 고조파 진단 툴 개발)

  • 설용태;이의용
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.63-68
    • /
    • 2002
  • In this paper harmonic diagnose tool is described for electric evaluate the power quality at industrial power systems is described both simulation and experimental testing during various operation conditions. PTW (Power Tools for Windows) and harmonic measuring instrument are organized around personal computer and/or instrumentation study environments interconnected via RS-232. Unknown zero sequence impedance data of cable is calculated by the modified T&D and BICC method. IEEE standard is also used to estimate the transformer input data. the proposed system provides a flexible and effective environment to diagnose the power quality at industrial distribution systems by utilizing simulations and actual field data.

  • PDF