A Study on Soft-Mooring Model Test Techniques for the Evaluation of Added Resistance on Ships (선박의 부가저항 평가를 위한 소프트 계류 모형시험 기법 연구)

  • Min-Guk Seo;In Bo Park;Dong-Min Park;Seunghyun Hwang
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.5
    • /
    • pp.320-331
    • /
    • 2023
  • In this study, a model test was conducted using the soft-mooring technique to evaluate the added resistance of the ship in waves. The study also examined the specific factors that should be considered during the soft-mooring test. The main purpose of soft-mooring is to prevent drifting caused by waves by providing horizontal restoring forces. However, it can also create undesired restoring forces in the vertical direction. Therefore, we examined the restoring force of the ship's 6-DOF motion based on the arrangement of the soft-mooring and the height of the mooring connection point. We also checked the corresponding resonance period and drift distance. The soft-mooring test was conducted twice, once with self-propulsion and once without self-propulsion, allowing us to review the advantages and disadvantages of each test technique. The main parameters measured in these model tests were 6DOF motion and added resistance on the ship. We compared these measurements obtained from two different techniques (with and without self-propulsion). Additionally, we also compared the measurements based on the types of measuring sensors used (2D load cells on FP, AP, and 1D load cells on each mooring line) as well as the height of the mooring connection point.

A Multicenter Pilot Study of Biliary Atresia Screening Using Digital Stool Color Imaging

  • Kannamon Waitayagitgumjon;Wannisa Poocharoen;Suchin Trirongjitmoah;Kriengsak Treeprapin;Arada Suttiwongsing;Thetiya Wirifai;Chira Trirongchitmoh;Pitiporn Tangkabuanbutr
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.3
    • /
    • pp.168-175
    • /
    • 2024
  • Purpose: The presence of alcoholic stool in biliary atresia (BA) patients is the basis of a stool color card (SCC), a screening tool that has led to more patients receiving Kasai portoenterostomy earlier. This study aimed to evaluate the color image processing of stool images captured using smartphones. We propose that measuring digital color parameters is a more objective method for identifying BA stools and may improve the sensitivity of BA screening. Methods: A prospective study was conducted in five hospitals in Thailand between October 1, 2020, and December 31, 2021. Stools from infants presenting with jaundice, acholic stool, or dark-colored urine were photographed. Digital image color analysis was performed, and software was developed based on the color on the original SCC. Sensitivity and specificity for predicting BA stools were compared between the SCC and the software. Results: Of 33 infants eligible for data collection, 19 were diagnosed with BA. Saturation and blue were two potential digital color parameters used to differentiate BA stools. The receiver operating characteristic curve was used to determine the optimum cutoff point of both values, and when saturation ≤56 or blue ≥61 was set as a threshold for detecting BA stool, high accuracy was achieved at 81.8% and 78.8%, respectively. Conclusion: Digital image processing is a promising technology. With appropriate cutoff values of saturation in hue, saturation, value and blue in red, green, blue color models, BA stools can be identified, and equivocal-colored stools of non-BA patients can be differentiated with acceptable accuracy in infants presenting with jaundice.

Ultrasonographic evaluation of pennation angle in canine tibialis cranialis muscle in South Korea: an observational study

  • Jaehwan Kim;Tae Sung Hwang;Hee Chun Lee
    • Korean Journal of Veterinary Research
    • /
    • v.64 no.2
    • /
    • pp.14.1-14.6
    • /
    • 2024
  • In human, ultrasonography is used to measure the pennation angle in various muscles to identify muscle functions such as force production, and to study alterations of the pennation angle during muscle contraction, hypertrophy, and atrophy. However, assessments of the pennation angle have not yet been conducted in dogs. This study aims to assess the normal pennation angle of the tibialis cranialis muscle in dogs using ultrasound and to detect changes in this angle in dogs with muscular atrophy. Sixty-eight healthy dogs were examined to establish normal values, while 12 ataxic and 12 lame dogs with suspected hindlimb muscle atrophy were also included. The pennation angle was measured using ultrasound at the midpoint between the proximal end of the tibia and the malleolus, measuring the angle between the muscle bundle and the deep aponeurosis. To confirm the significance between the 5 breeds and to identify a difference between normal and atrophied muscles, statistical analysis was conducted. The study found no significant difference in pennation angle between breeds, with mean values (± standard deviation) of 4.97° (± 1.88) in neutral, 7.25° (± 2.68) in flexion, and 3.31° (± 1.33) in extension positions. Decrease of the pennation angle was identified in muscle atrophy and the flexion position was determined to be the most appropriate for pennation angle measurement of tibialis cranialis muscle. We recommend considering the pennation angle as a valuable indicator of muscle health in dogs, as it demonstrates significant potential for diagnosing and monitoring muscular conditions.

A study on the improvement of fishing system using miniaturized nets for anchovy boat seine to reduce the fleet size (선단축소형 권현망 어구를 적용한 조업시스템 개선 방안)

  • Young-Su AN;Bo-Yeon KIM;Youn-Hyoung CHO;Jong-Kap AHN
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.3
    • /
    • pp.207-216
    • /
    • 2024
  • This study conducted a marine experiment to improve the fishing system using miniaturized nets for anchovy boat seine to reduce the fleet size. As a result, the miniaturized net for anchovy boat seine properly opened the entrance of the bag net using the buoyancy of the flotation for position indication and the setting force of the ground rope without operating a separate fish detecting boat by attaching a large flotation at the entrances of the inside wing net and the bag net. This also enabled an operation type where the entrance of the bag net is confirmed using a flotation for position indication from a netting boat. The time and the number of people used for net casting and net hauling in the marine experiment were average of five minutes and 25-30 minutes, respectively, and 23-30 people for the existent net, while for the miniaturized large-scale net were average of three minutes and 23-25 minutes, respectively, and 19-25 people. This indicates that the operation time was shortened, the number of fish detecting boats was reduced by one boat, and the number of people for fishing work was decreased by four or five people due to the improvement of fishing operation system according to the reduction of fishing net size. As a result of measuring the shaft horsepower during net towing, the maximum net towing horsepower was 250 HP in comparison to the maximum RPM of the engine (1,200 RPM), indicating that the legal horsepower of 250 HP is enough to conduct net towing and the competitiveness of fishing using the net for anchovy boat seine is ensured through operation cost reduction.

Application of ML algorithms to predict the effective fracture toughness of several types of concret

  • Ibrahim Albaijan;Hanan Samadi;Arsalan Mahmoodzadeh;Hawkar Hashim Ibrahim;Nejib Ghazouani
    • Computers and Concrete
    • /
    • v.34 no.2
    • /
    • pp.247-265
    • /
    • 2024
  • Measuring the fracture toughness of concrete in laboratory settings is challenging due to various factors, such as complex sample preparation procedures, the requirement for precise instruments, potential sample failure, and the brittleness of the samples. Therefore, there is an urgent need to develop innovative and more effective tools to overcome these limitations. Supervised learning methods offer promising solutions. This study introduces seven machine learning algorithms for predicting concrete's effective fracture toughness (K-eff). The models were trained using 560 datasets obtained from the central straight notched Brazilian disc (CSNBD) test. The concrete samples used in the experiments contained micro silica and powdered stone, which are commonly used additives in the construction industry. The study considered six input parameters that affect concrete's K-eff, including concrete type, sample diameter, sample thickness, crack length, force, and angle of initial crack. All the algorithms demonstrated high accuracy on both the training and testing datasets, with R2 values ranging from 0.9456 to 0.9999 and root mean squared error (RMSE) values ranging from 0.000004 to 0.009287. After evaluating their performance, the gated recurrent unit (GRU) algorithm showed the highest predictive accuracy. The ranking of the applied models, from highest to lowest performance in predicting the K-eff of concrete, was as follows: GRU, LSTM, RNN, SFL, ELM, LSSVM, and GEP. In conclusion, it is recommended to use supervised learning models, specifically GRU, for precise estimation of concrete's K-eff. This approach allows engineers to save significant time and costs associated with the CSNBD test. This research contributes to the field by introducing a reliable tool for accurately predicting the K-eff of concrete, enabling efficient decision-making in various engineering applications.

The Effects of Work Characteristics of Grapes-harvesting Tasks on the Wrist and Elbow Angles (포도 수확 작업의 작업특성에 따른 손목과 팔꿈치 각도 영향 분석)

  • Kim, Jihye;Lee, Inseok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.589-599
    • /
    • 2017
  • Objective: The objective of this study was to measure the upper-limb motions and postures of grapes-harvesting tasks using electrical goniometers and analyze the upper-limb motions in a kinematic way to assess the risk of musculoskeletal disorders. Background: Grapes farmers are exposed to various risk factors of musculoskeletal disorders (MSDs) such as repetitive upper-limb motions, non-neutral postures, and manual handling of heavy items. The farmers have to use scissors repetitively while harvesting grapes with their being arms elevated over the shoulder height, which presumed to increase the physical workload. It has been reported that the grapes farmers feel the harvesting task as the one of the hardest work in cultivating grapes. We tried measure the wrist and elbow angles while the farmers were carrying out harvesting tasks to understand how much workload the work impose on the farmers, which can be helpful in making interventions of preventing musculosksletal disorders among grapes farmers. Method: We measured joint angles at the right wrist and elbow with a wireless measuring system with two electrical goniometers from five grape farmers. The grapes-harvesting task was classified into 6 different subtasks: 1) searching, 2) picking, 3) cleaning, 4) carrying, 6) storing, and 7) miscellaneous tasks. The subtasks were compared by mean angles, 10%, 50%, and 90% APDF values of wrist flexion/extension, ulnar/radial deviation, and elbow flexion. Results: The Kruskal-Wallis tests showed that the 10th percentiles of APDF of ulnar/radial deviation and flexion/extension of the wrist significantly differs among subtasks (p<0.05). It was found that the farmers assumed more deviated wrist postures in the ulnar direction when they picking and adjusting the grapes. The use of scissors seemed to force the farmers to severely bend their wrist in the directions of ulnar deviation and flexion. The grapes-harvesting task showed similar wrist postures and motion with poultry deboning and milking tasks. Conclusion: The grapes harvesting tasks make the farmers take ulnar deviated and extended postures in the wrist. The use of scissors makes them take more severely deviated postures in the wrist. Safety guidelines including use of ergonomic scissors can be provided to the farmers to improve their work conditions. Application: The results of this study can be used as a basic data for the development of safety guidelines for agricultural work.

TENSILE BOND STRENGTH OF ALUNMINA CORE TREATED BY ION ASSISTED REACTION (이온보조반응법으로 처리한 알루미나 코아의 인장결합강도에 관한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung;Kwon, Kung-Rock;Choi, Boo-Byung;Choi, Won-Kook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.704-723
    • /
    • 2000
  • This study was undertaken to evaluate the tensile bond strength of In-Ceram alumina core treat-ed by ion assisted reaction(IAR). Ion assisted reaction is a prospective surface modification technique without damage by a keV low energy ion beam irradiation in reactive gas environments or reactive ion itself. 120 In-Ceram specimens were fabricated according to manufacturer's directions and divided into six groups by surface treatment methods of In-Ceram alumina core. SD group(control group): sandblasting SL group: sandblasting + silane treatment SC group: sandblasting + Siloc treatment IAR I group: sandblasting + Ion assisted reaction with argon ion and oxygen gas IAR II group: sandblasting + Ion assisted reaction with oxygen ion and oxygen gas IAR III group: sandblasting + Ion assisted reaction with oxygen ion only For measuring of tensile bond strength, pairs of specimens within a group were bonded with Panavia 21 resin cement using special device secured that the film thickness was $80{\mu}m$. The results of tensile strength were statistically analyzed with the SPSS release version 8.0 programs. Physical change like surface roughness of In-Ceram alumina core treated by ion assistad reaction was evaluated by Contact Angle Measurement, Scanning Electron Microscopy, Atomic Force Microscopy; chemical surface change was evaluated by X-ray Photoelectron Spectroscopy. The results as follows: 1. In tensile bond strength, there were no statistically significant differences with SC group, IAR groups and SL group except control group(P<0.05). 2. Contact angle measurement showed that wettability of In-Ceram alumina core was enhanced after IAR treatment. 3. SEM and AFM showed that surface roughness of In-Ceram alumina core was not changed after IAR treatment. 4. XPS showed that IAR treatment of In-Ceram alumina core was enabled to create a new functional layer. A keV IAR treatment of In-Ceram alumina core could enhanced tensile bond strength with resin cement. In the future, this ion assisted reaction may be used effectively in various dental materials as well as in In-Ceram to promote the bond strength to natural tooth structure.

  • PDF

A Promotion Plan through Measuring the Utilization of Information Classification Systems in the Construction Industry (건설정보 분류체계 활용도 측정을 통한 분류체계 활성화 방안)

  • Park, Hwan-Pyo;Lee, Jae-Seob
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.6 s.22
    • /
    • pp.90-100
    • /
    • 2004
  • The importance of information management has been emphasized in Korean construction industry, Both public and private have invested to establish and operate construction CALS, construction management (CM), computer integrated construction(CIC), and earned value management system(EVMS). A standard construction information classification system is essential to operate the systems mentioned above. Therefore, Korean government released Integrated Construction Information Classification System(ICICS) in 2001. However, the ICICS is not widely used in construction due to: 1) difficulty of changing existing system, 2) insufficient publicity of the ICICS, and 3) no legal binding force. Especially, participants in construction do not recognize applicability of the ICICS. This research surveyed the degree of recognition and utilization of the ICICS. This survey includes both customized classification systems used by companies and the ICICS and investigates the degree of utilization and drawbacks. The results show some construction companies use their own classification systems and the others use the ICICS prepared by the government. Furthermore, the degree of recognition is in sufficient. The degree of use in design management, specifications, cost and schedule management is very limited. The publicity and education are critical to induce the utilization of the ICICS. The necessity of revision was recommended based on pilot project study that is performed to measure the degree of application of ICICS on the projects. Therefore, this research proposes the measurement model for information application and analyzes the degree of utilization of the ICICS in different phases of construction.

Experimental Analysis on Vibration of Composite Plate by Using FBG Sensor System (브래그 격자 센서 시스템을 이용한 복합재 평판 진동의 실험적 해석)

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.436-441
    • /
    • 2009
  • A fiber optic sensor is prospective to be applied to structural health monitoring. Especially, a fiber Bragg grating(FBG) sensor is one of the most popular sensors for the structural health monitoring. The FBG sensor has several demodulation systems for tracking the shift of the Bragg wavelength. The dynamic bandwidth is dependent on the demodulation system. In this paper, the sensing mechanism is that the slope of the optical spectrum of FBG could be used as its sensitivity when the tunable laser shot the monochromatic laser wavelength at the highest slope point. In this technique, the high sensitivity is guaranteed even though the sensing range is limited. In an example of the application, the composite plate embedding a FBG sensor was manufactured by using an autoclave method and the above sensing mechanism was applied to the composite plate. Firstly, the natural frequencies of the plate were successfully measured by the FBG sensor during the impact hammer test. Secondly, a high-power speaker was used to force the plate to be vibrated at the specific frequency that was one of the natural frequencies. During the shaking, the FBG sensor measures the dynamic characteristics and ESPI was also used to measure the mode shape. From the two dynamic tests, the availability of the FBG sensor system and the ESPI was proven as a technique for measuring the dynamic characteristics of composite structure.

THE EFFECTS OF VARIOUS ALL-ETCHING AGENTS AND VARIED ETCHING TIME ON ENAMEL MORPHOLOGY AND BOND STRENGTH (수종의 All-Etching Agent와 산부식시간에 따른 법랑질 산부식형태 및 전단 결합강도에 관한 연구)

  • Kwon, So-Ran;Yoon, Tae-Hyun;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.136-149
    • /
    • 1996
  • The effects of various All-Etching Agents (10% phosphoric acid, 10% maleic acid and 10 % citric acid) and 32 % phosphoric acid and varied etching time were evaluated by observing the morphology of the etched enamel surfaces using Scanning electron microscopy and by measuring the shear bond strength of a composite resin to human enamel. A total of 156 extracted premolar and molar teeth free of irregularities were employed in this study. Specimens for the observation of enamel morphology were divided into 12 groups of 3 teeth each, based on the type of etchant used and application time. After exposure to the etching agent specimens were washed air-dried and then glued to aluminum stubs and coated with a layer of gold for examination in the scanning electron microscope. Specimens for the evaluation of bond strength were divided into 12 groups of 10 teeth each also based on the type of etchant used and application time. After exposure to the etching agent the specimens were washed, air-dried and a thin layer of bonding agent was applied using a brush. Z 100 composite resin was light cured to the surface and stored at $37^{\circ}C$, 100% humidity for 7 days. An Instron Universal Testing Machine was used to apply a shearing force at $90^{\circ}$ angle from the enamel surface. It is concluded from this study that commercial All-etching agents can be used with a 15-second etching without adversely affecting retention of dental resin materials. At the same time, the acid concentration is probably a suitable compromise regarding the acid's function as a dentin demineralizing all-etch conditioning agent. The following results were obtained. 1. Specimens etched with 10 % citric acid showed a random superficial etching pattern which could not be related to prism morphology. 2. Specimens etched with 10 % and 32 % phosphoric acid and 10 % maleic acid showed a type I pattern in which core material was preferentially removed leaving the prism peripheries relatively intact or a type II pattern in which prism peripheries were preferentially removed. This delineation became more distinguished as etching time was increased. 3. All-Etching Agents and 32 % phosphoric acid showed a statistically significant higher shear bond strength at 15 seconds etching time.(p<0.05) 4. 10 % maleic acid and 32 % phosphoric acid exhibited a statistically significant higher shear bond strength than 10 % phosphoric and citric acid at 15 seconds etching time.(p<0.05).