• 제목/요약/키워드: measurement validation

검색결과 698건 처리시간 0.027초

Force identification by using specific forms of PVDF patches

  • Chesne, Simon;Pezerat, Charles
    • Smart Structures and Systems
    • /
    • 제15권5호
    • /
    • pp.1203-1214
    • /
    • 2015
  • This paper deals with the experimental validation of the use of PVDF Patches for the assessment of spatial derivatives of displacement field. It focuses more exactly on the shear Force Identification by using Specific forms of PVDF patcHes (FISH) on beams. An overview of the theoretical approach is exposed. The principle is based on the use of the weak form of the equation of motion of the beam which allows the shear forces to be extracted at one edge of the sensor when this last has a specific form. The experimental validation is carried out with a cantilever steel beam, excited by a shaker at its free boundary. The validation consists in comparing the shear force measured by the designed sensor glued at the free edge and the directly measured force applied by the shaker. The sensor is made of two patches, called the "stiffness" patch and the "mass" patch. The use of both patches allows one to identify correctly the shear force on a large frequency domain. The use of only the stiffness patch is valid in the low frequency domain and has the advantage to have a frequency-independent gain that allows its use in real time.

KRISO 138K LNG 운반선 모형 주위의 국부 유동장 계측 (Measurement of flow around KRISO 138K LNG Carrier Model)

  • 반석호;윤현세;이영연;박일룡;이춘주;김우전
    • 대한조선학회논문집
    • /
    • 제40권2호
    • /
    • pp.1-10
    • /
    • 2003
  • It is important to understand the flow characteristics such as wave and wake development around a ship for the design of the hull forms with better resistance and propulsive performance. The experimental results explicating the local flow characteristics are also invaluable for validation of the physical and numerical modeling of CFD codes, which are recently gaining acknowledgements as efficient tools for hull form evaluation This paper describes velocity and wave profiles measured in the towing tank for the KRISO 138K LNG Carrier (KLNG) model with propeller and rudder. The results contained in this paper can provide the valuable information on the effect of propeller and rudder on stern flow characteristics of the modern commercial hull form, furthermore, the present experimental data will provide important database for CFO validation.

전력시스템 고조파 상태 추정에서 면역 알고리즘 적용 (Application of Immune Algorithm for Harmonic State Estimation)

  • 왕용필;박인표;정형환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권12호
    • /
    • pp.645-654
    • /
    • 2004
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic analysis measurement instruments is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using Immune Algorithm (IAs). This IA-HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using Immune Algorithm (IAs) in the HSE.

CIE 권장가이드를 이용한 자연채광 기후요소 측정시스템의 유효성 검증 (Validation of a Daylight Measurement System Using the CIE Guide of Recommended Practice of Daylight Measurement)

  • 공효주;이종수;김곤;윤근영;김정태
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.41-46
    • /
    • 2010
  • This study is to validate the K University daylight measurement system according to the CIE guide of recommended practice of daylight measurement. In this study global irradiance, illuminance, direct normal illuminance, diffuse irradiance, illuminance and vertical illuminances(North, West, South, East) were measured and compared in accordance with the CIE quality control test. Field monitoring was conducted from 1st August to 15th August 2010. Results for the CIE tests 1 to 4 showed an accuracy of 100%. This indicates that the K University daylight measurement system is reliable and the measurement data would be useful for further daylight researches.

운영리스크 VaR 추정값의 안정성검증 방법 연구 (A Study on VaR Stability for Operational Risk Management)

  • 김현중;김우환;이상철;임종호;조상희;김아현
    • Communications for Statistical Applications and Methods
    • /
    • 제15권5호
    • /
    • pp.697-708
    • /
    • 2008
  • 본 논문은 금융기관에서 활용하고 있는 운영리스크 측정모형에 대한 적합성검증 방법 중 안정성 검증에 관한 것이다. 신용리스크와는 달리 운영리스크는 손실자료의 특징, 과거 자료의 부족 그리고 적합성검증을 위한 이론적 도구의 부족 등으로 인해 현재 적절한 적합성검증 방안에 제시되지 못하고 있다. 본 논문에서는 운영리스크 VaR(Value at Risk) 추정값의 안정성을 평가하는 적합성검증 방법을 제시하고 이를 활용한 실증분석을 통해 제안된 방법에 대한 실제적 활용 가능성을 확인해 보고자 한다. 구체적으로 본 논문에서는 붓스트랩 방법을 활용하여 운영리스크 VaR의 신뢰구간을 생성함으로써 운영리스크 VaR 추정값의 안정성을 검증하는 기법을 제안하였으며, 이를 토대로 적합에 따른 운영리스크 VaR 추정값의 안정성을 측정하는 방안도 제시하였다.

권역심뇌혈관질환센터의 공익성 측정도구 개발 (Development and Validation of the Measurement Tool of Public Benefits in Regional Cardiocerebrovascular Center)

  • 이건세;신은영;정효선;이정현;김희숙;임영실;김영택Kun
    • 보건행정학회지
    • /
    • 제23권4호
    • /
    • pp.434-444
    • /
    • 2013
  • Background: Regional Cardiocerebrovascular Centers (RCC) were established for the prevention and treatment of cardiocerebrovascular disease and funded by the Ministry of Health and Welfare. The purpose of this study was to develop and validate the measurement tool of public benefits in RCC. Methods: Through the intensive literature review, experts surveys and their repetitive feedback, we selected the 46 items about the public benefits in RCC. Development of measurement tool involved content validity test using Content Validity Index (CVI), construct validity test through factor analysis and reliability test. Results: Thirty-five items were selected by content validity test, which CVI was 0.08 or higher. Through the construct validity test, 32 items in 7 factors were derived. And Cronbach's alpha was 0.951. Finally, public benefits measurement tool is composed of 32 items in 7 factors which are comprehensiveness of health care services, market complement, emergency care, cost, governance, quality improvement, and government control. Conclusion: Though we developed the measurement tool of public benefits in RCC, it would be utilized to measure the public benefits of various health agencies.

IEEE 802.11 네트워크에서 효율적인 라디오 자원 측정 시스템 연구 (Efficient Radio Resource Measurement System in IEEE 802.11 Networks)

  • 양승철;이성호;김종덕
    • 한국정보통신학회논문지
    • /
    • 제16권11호
    • /
    • pp.2437-2445
    • /
    • 2012
  • 본 논문은 무선 매체의 점유 요인을 분석하여 효율적인 라디오 자원 측정 방법을 제안한다. 미디엄 점유 시간은 무선 단말이 현재 채널에서 802.11 프레임, 무선 간섭, 프로토콜 대기 시간에 의해 점유된 시간으로 다양한 분야에서 성능 측정 도구로 이용된다. 기존 연구들은 부분적인 요인만을 측정하고, 측정 도구에 대한 검증 및 다양한 라디오에 대한 확장성이 부족하다. 본 논문은 세분화된 점유 요인들의 측정 방법을 제안한다. 이를 위해 무선 칩셋의 레지스터 정보 수집, 가상 모니터 모드를 통한 프레임 분석을 위해 802.11n 기반 OpenHAL 디바이스 드라이버를 수정하였다. 뿐만 아니라 다양한 검증 방법을 통해 정확한 미디엄 점유 시간을 도출한다.

휴대용 뇨당 측정 시스템의 개발 (Development of an Portable Urine Glucose Monitoring System)

  • 박호동;이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.397-403
    • /
    • 2002
  • 뇨당 측정 시스템은 소변 속의 글루코오스 농도를 측정함으로서 당뇨 수치를 모니터링하는 비침습적인 당뇨병 자가 진단 장치이다. 본 논문에서는 기존의 침습형 혈당측정방법의 불편성과 비색계를 이용한 뇨당 검사법의 단점을 보완한 뇨당 측정시스템을 설계하였다. 뇨당 측정시스템은 뇨당 측정용 화학센서, 신호검출부, 디지털 제어 및 신호분석부, 디스플레이부 및 전원부로 구성된다. 뇨당측정용 센서로는 재현성이 뛰어나고 다루기가 간편하며 저렴한 가격으로 대량 생산할 수, 있는 일회용 뇨당측정용 전류화학센서를 개발하였다. 설계한 뇨당 측정시스템의 성능을 평가하기 위하여 사람의 소변에 임의의 농도의 글루코오스 성분을 섞은 용액에 대하여 글루코오스 성분 분석시 사용되는 표준장비와의 비교분석을 통해서 글루코오스 농도 검출에 대한 신뢰성 평가를 수행하였다. 회귀분석에 기초한 신뢰성 평가를 수행한 결과 표준오차는 2.85282로 나타났다. 또한, 화학센서를 사용해서 측정하는 시스템을 평가 시 중요한 파라미터인 S.D(Standard Deviation)는 10%로서 임상적으로 유효한 15% 범주 내에 있음을 확인하였고, C.V(Coefficient of Validation)값은 ,5%이내이므로 혈당센서의 기준으로 평가해 볼때 만족하는 결과를 보였다.

Quantitative analysis and validation of naproxen tablets by using transmission raman spectroscopy

  • Jaejin Kim;Janghee Han;Young-Chul Lee;Young-Ah Woo
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.114-122
    • /
    • 2024
  • A transmission Raman spectroscopy-based quantitative model, which can analyze the content of a drug product containing naproxen sodium as its active pharmaceutical ingredient (API), was developed. Compared with the existing analytical method, i.e., high-performance liquid chromatography (HPLC), Raman spectroscopy exhibits high test efficiency owing to its shorter sample pre-treatment and measurement time. Raman spectroscopy is environmentally friendly since samples can be tested rapidly via a nondestructive method without sample preparation using solvent. Through this analysis method, rapid on-site analysis was possible and it could prevent the production of defective tablets with potency problems. The developed method was applied to the assays of the naproxen sodium of coated tablets that were manufactured in commercial scale and the content of naproxen sodium was accurately predicted by Raman spectroscopy and compared with the reference analytical method such as HPLC. The method validation of the new approach was also performed. Further, the specificity, linearity, accuracy, precision, and robustness tests were conducted, and all the results were within the criteria. The standard error of cross-validation and standard error of prediction values were determined as 0.949 % and 0.724 %, respectively.

측정치 개수 제한기법을 이용한 HPDA 알고리즘 성능향상 연구 (The Improvement of the Highest Probability Data Association algorithm with Limited Measurement Numbers(HPDA-LIMN) in the Validation Gate)

  • 임영택;홍영기
    • 한국군사과학기술학회지
    • /
    • 제14권5호
    • /
    • pp.812-817
    • /
    • 2011
  • In this paper, we propose new data association method called the Highest Probability Data Association with Limited Measurement Numbers(HPDA-LIMN) using a Signal Itensity Ordering method applied to tracking in clutter environment. The performance of HPDA-LIMN algorithm is tested in a series of Monte Carlo simulations runs and is compared with the exiting data association method in cluttered environment.