• Title/Summary/Keyword: measurement validation

검색결과 698건 처리시간 0.027초

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

Image Tracking Algorithm using Template Matching and PSNF-m

  • Bae, Jong-Sue;Song, Taek-Lyul
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권3호
    • /
    • pp.413-423
    • /
    • 2008
  • The template matching method is used as a simple method to track objects or patterns that we want to search for in the input image data from image sensors. It recognizes a segment with the highest correlation as a target. The concept of this method is similar to that of SNF (Strongest Neighbor Filter) that regards the measurement with the highest signal intensity as target-originated among other measurements. The SNF assumes that the strongest neighbor (SN) measurement in the validation gate originates from the target of interest and the SNF utilizes the SN in the update step of a standard Kalman filter (SKF). The SNF is widely used along with the nearest neighbor filter (NNF), due to computational simplicity in spite of its inconsistency of handling the SN as if it is the true target. Probabilistic Strongest Neighbor Filter for m validated measurements (PSNF-m) accounts for the probability that the SN in the validation gate originates from the target while the SNF assumes at any time that the SN measurement is target-originated. It is known that the PSNF-m is superior to the SNF in performance at a cost of increased computational load. In this paper, we suggest an image tracking algorithm that combines the template matching and the PSNF-m to estimate the states of a tracked target. Computer simulation results are included to demonstrate the performance of the proposed algorithm in comparison with other algorithms.

초음속 풍동의 추력 측정 방법 비교 (Comparison of Thrust Measurement of a Supersonic Wind Tunnel)

  • 허환일;김형민
    • 한국항공우주학회지
    • /
    • 제31권5호
    • /
    • pp.93-99
    • /
    • 2003
  • 극초음속 추진기관의 설계 및 평가에 있어 추력의 측정은 매우 중요하다. 일반적인 추력 측정방법으로는 추력 측정기를 사용하고 있지만 이러한 방법으론 엔진의 자유제트 실험이나 모델 연소기 같은 실험에는 적용이 부적절하다. 이 때문에 피토압력을 이용한 새로운 추력 계산 방법을 고려하였고 검증하였다. 피토 압력을 통해 계산된 추력의 검증은 추력측정기를 통해 측정된 실제 추력값과의 비료를 통해 이루어질 수 있으며 이를 위해 추력측정기 위에 소형 초음속 풍동을 장착하였다. 추력이 측정되는 동안 충동 후방의 피토압력을 동시에 측정하였다. 측정된 피토 압력을 이용하여 구한 추력값을 검증하기 위해서, 추력측정기로 측정한 추력을 완정팽창 노즐이론 및 추력계수를 이용한 이론적인 계산에 의해 구해진 추력값과 비료, 분석하였다.

Validation and measurement uncertainty of HPLC-UV method for quercetin quantification in various foods

  • Seo, Eunbin;Lim, Suji;Yun, Choong-In;Shin, Jae-Wook;Kim, Young-Jun
    • 한국식품과학회지
    • /
    • 제53권6호
    • /
    • pp.682-687
    • /
    • 2021
  • The purpose of this study was to validate a high-performance liquid chromatography (HPLC) method for the quantitative analysis of quercetin in various foods. The method was based on HPLC-UV (360 nm). The method was validated using candy, beverage, and sausage which were tested for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. Matrix-matched calibration was also applied. The calibration curves (0.5-50 mg/L) showed good linearity (r2≥0.9998). LOD and LOQ ranged from 0.15 to 0.31 mg/kg and from 0.44 to 0.93 mg/kg, respectively. The average accuracy and precision at 0.5, 2.5, and 10 mg/kg ranged from 84.3 to 102.0% and 0.7 to 3.0 relative standard deviation (RSD%), respectively. This study confirmed the applicability of the proposed method by applying it to commercial products, such as teas and beverages. Thus, the proposed analytical method is suitable for quantifying quercetin in various foods.

Validation and measurement uncertainty of HPLC method for simultaneous determination of 10 dyes in adulterated Phellodendron

  • Lim, Suji;Yun, Choong-In;Ko, Kyung Yuk;Kim, Young-Jun
    • 한국식품과학회지
    • /
    • 제53권4호
    • /
    • pp.391-398
    • /
    • 2021
  • As global interest in herbal medicines has increased, the adulteration of herbal medicines has become a critical safety issue. Adulteration with dyes to improve the appearance of low-quality products is of particular concern. This study aimed to develop a high-performance liquid chromatography (HPLC) method to detect dyes added as adulterants to Phellodendron. Samples were analyzed on a C18 column using 50 mM ammonium acetate and acetonitrile as the mobile phase. All calibration curves showed good linearity (r2 ≥0.9999) over the five-point concentration range (1-50 mg/kg). Limit of detection ranged from 0.04-0.35 mg/kg, and limit of quantification ranged from 0.11-1.07 mg/kg. The repeatability and reproducibility for these measurements were 94.2-103.3% and 96.6-103.8% for accuracy and 0.14-2.28 RSD (%) and 0.80-2.37 RSD (%) for precision. Moreover, the measurement uncertainty of the low, medium, and high concentrations for 10 dyes was considered. Thus, this HPLC method is suitable for detecting color adulteration of Phellodendron.

잔향 수조에서의 시간 이력 수음 신호 간 교차상관을 이용한 수중 음속 계측 방법에 관한 실험적 검증 (Experimental Validation on Underwater Sound Speed Measurement Method Using Cross-Correlation of Time-Domain Acoustic Signals in a Reverberant Water Tank)

  • 이주엽;김국현;박성주;조대승
    • 대한조선학회논문집
    • /
    • 제61권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Underwater sound speed is an important analysis parameter on an estimation of the underwater radiated noise (URN) emitted from vessels. This paper aims to present an underwater sound speed measurement procedure using a cross-correlation of time-domain acoustic signals and validate the procedure through an experiment in a reverberant water tank. For the purpose, time-domain acoustic signals transmitted by a Gaussian pulse excitation from an acoustic projector have been measured at 20 hydrophone positions in the reverberant water tank. Then, the sound speed in water has been calculated by a linear regression using 190 cross-correlation cases of distances and time lags between the received signals and the result has been compared with those estimated by the existing empirical formulae. From the result, it is regarded that the presented experimental procedure to measure an underwater sound speed is reliably applicable if the time resolution is sufficiently high in the measurement.

탐지문턱값 적응기법을 이용한 표적추적 유효화 영역의 최적화 (Optimization of the Validation Region for Target Tracking Using an Adaptive Detection Threshold)

  • 최성린;김용식;홍금식
    • 한국항공우주학회지
    • /
    • 제30권2호
    • /
    • pp.75-82
    • /
    • 2002
  • 불확실한 측정값 근원의 문제에서는 표적을 최적으로 탐지해내는 것이 유용하다. 본 논문에서는 클러터 환경에서 표적을 추적하는 경우에 탐지확률 및 오경보확률과 동시에 탐지문턱값 처리에 따른 추적오차를 살펴보고, 문턱값과 표적추적 유효화영역의 최적화 알고리즘을 제안한다. 제안한 알고리즘은 시뮬레이션을 통해 상태추정오차공분산의 측면에서 성능을 분석한다.

In-situ 소음투과손실 측정 및 검증을 위한 기법 개발 (New Method for Measurement and Validation of In-situ Sound Transmission Loss)

  • 이화수;박홍철;윤성호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.795-800
    • /
    • 2008
  • The sound transmission loss is a key index to evaluate the acoustic performance of a car-body structure at the high frequency range. From this paper, a new validation method for in-situ sound transmission loss is proposed. First, in-situ sound transmission loss is measured by using PU intensity probe on the condition of complete vehicle. Second, validation test, which is consisted of internal, external and total frequency response function test, is performed by using volume acceleration source and microphones. Then, these test results are compared to validate the accuracy of in-situ sound transmission loss. Finally, the test result of in-site method is compared with results of two reverberant room test method and SEA analytical method. The reliability of in-situ method is confirmed by these procedures.

  • PDF

Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

  • Chung, Kwangzoo;Han, Younyih;Ahn, Sung Hwan;Kim, Jin Sung;Nonaka, Hideki
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.267-271
    • /
    • 2016
  • In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at Samsung Proton Therapy Center. Following a successful completion of the acceptance test, the commissioning process including the beam data measurement for treatment planning system has been conducted. Extended measurements have been conducted as a validation of the clinical performance of the nozzle and various quality assurance protocols have been prepared.