• Title/Summary/Keyword: measurement time

Search Result 9,284, Processing Time 0.041 seconds

A Study on the Health Care Satisfaction and Attitude of Elementary School Students - by the presence or absence of nurse teacher - (초등학생의 보건관리 만족도와 태도에 관한 연구 - 양호교사 유무를 중심으로 -)

  • Park, Dong-Kwon;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.49-71
    • /
    • 2000
  • The purpose of this study was to serve as a basis for school health care of better quality, by making a comparative analysis of the health care satisfaction and attitude of elementary school students in consideration of their general characteristics and the presence or absence of nurse teacher. The subjects in this study were 919 selected six graders in 16 elementary schools in the city of Tongduchun, Koyang and Euijungbu, Yangju-kun and Yeunchun-kun. A survey was conducted with questionnaire designed for measurement of health care satisfaction and attitude. As a result of analyzing the data collected from June 1 through 15, 2000, the conclusions were as follows. 1) As for the general characteristics of the students investigated, the subjects included 513 boys(55.8%) and 406 girls(44.2%). The schools where 390(42.4%) students attended were located in municipal area, and the schools where 529(57.6%) students attended were located in kun area. 608(66.2%) students had a nurse teacher at their schools, while 311(33.8%) students had no nurse teacher. 498(54.2%) had an experience to use the health room this year, but 421(45.8%) had no such an experience. Their mean school life satisfaction was scored $3.42{\pm}.71$, above the average. And their health condition was rated $3.81{\pm}.87$, which implied they tended to be in good health. 2) The mean satisfaction at the health room operation was scored $3.33{\pm}.71$, above the medium level. What they were most satisfied with($4.02{\pm}1.08$) was, among the health room facilities, that there were beds. But they expressed the least satisfaction($2.83{\pm}1.17$) at the location of health room. The presence or absence of nurse teacher made a significant difference to their satisfactionat health room operation, because the students in schools with nurse teacher showed greater satisfaction($3.42{\pm}.72$) than the others in schools with no nurse teacher did($3.15{\pm}.66$). 3) Concerning their attitude to use the health room in case of disease or accident occurrence, a lot of students in schools with a nurse teacher, who had ever suffered from indigestion, headache or traumatic injury, used the health room. In schools with no nurse teacher, there was a tendency to talk to their class teachers(p<.001). The recognition of the necessity for health counseling was generally on a medium level. The counselor whom they wanted to discuss health problem with was family or friend in the largest cases. Few students discussed with class teachers in case there was a nurse teacher in school. Instead, some of them discussed with friend, family or nurse teacher, and there was a significant difference between them(p<.001). 4) The mean satisfaction at health, sanitation and environmental management was rated $3.20{\pm}.90$, above the average. The classroom lighting gave them the best satisfaction with $3.67{\pm}1.07$, but the satisfaction at toilet cleanness and disinfection was not good with $2.83{\pm}1.19$. By the presence or absence of nurse teacher, those who had a nurse teacher expressed better satisfaction at water supply facilities including hot water than the others who had no nurse teacher did(p<.001). But no significant difference was observed in the other items. 5) The health education satisfaction was rated $3.19{\pm}.99$, which was on a medium level. By item, the mean satisfaction level was $3.36{\pm}1.19$ at nurse teacher's explanation about treatment, $3.13{\pm}1.15$ at the frequency of health education, and $3.08{\pm}1.16$ at the explanation on the cause of disease. By the presence or absence of nurse teacher, the students with nurse teacher showed significantly better satisfaction at every factor0(p<.001). 6) Regarding health education attitude, their recognition of the need for school health education was scored $3.89{\pm}.96$. Those who had a nurse teacher felt it more necessary($3.96{\pm}.92$), yet the others who had no nurse teacher felt its necessity a little less($3.74{\pm}1.01$). The most preferred thing for them to learn in health education was first aid, followed by sex education, obesity prevention, safety accident prevention in school and outdoors, smoking-related health, good use of leisure time, and environmental pollution cause in the order named. According to the presence or absence of nurse teacher, there was a significant difference in sex education(p<.01), but no significant disparities were found in the other factors. The most preferred person who would offer health education was a lecturer from the outside(45.8%) and nurse teacher(45.4%). Their preference for class teacher as a person in charge of health education was just 8.8%. But the presence or absence of nurse teacher didn't produce any differences to their preference for a person in charge of health education.

  • PDF

A Study on the Effect of O$_2$ annealing on Structural, Optical, and Electrical Characteristics of Undoped ZnO Thin Films Deposited by Magnetron Sputtering (산소 어닐링이 마그네 트론 스퍼터링으로 증착된 undoped ZnO박막의 구조적, 광학적, 전기적 특성에 미치는 영향에 대한 연구)

  • Yun, Eui-Jung;Park, Hyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.7
    • /
    • pp.7-14
    • /
    • 2009
  • In this paper, the effects of annealing conditions on the structural ((002) intensity, FWHM, d-spacing, grain size, (002) peak position), optical (UV peak, UV peak position) and electrical properties (carrier concentrations, resistivity, mobility) of ZnO films were investigated. ZnO films were deposited onto SiO$_2$/si substrates by RF magnetron sputtering from a ZnO target. The substrate was not heated during deposition. ZnO films were annealed in temperature ranges of $500\sim650^{\circ}C$ in the O$_2$ flow for 5$\sim$20 min. The film average thicknesses were in the range of 291 nm. The surface morphologies and structures of the samples were characterize by SEM and XRD, respectively. The optical properties were evaluated by photoluminescence (PL) measurement at room temperature (RT) using a He-Cd 325 nm laser. As the annealing temperature and time vary, the following relations were also observed: (1) proportional relationships among UV intensity (002) intensity, and grain size exist, (2) UV intensity is inversely proportional to FWHM, (3) there is no special relationship between UV intensity and electron carrier concentrations, (4) d-spacing is inversely proportional to (002) peak position, (5) UV peak position in the range of 3.20$\sim$3.24 eV means that ZnO films have a n-type conductivity which was consistent with that obtained from the electrical property, (6) the optimal conditions for the best optical and structural characteristics were found to be oxygen fraction, (O$_2$/(O$_2$+Ar)) of 0.2, RF power of 240W, substrate temperature of RT, annealing condition of 600$^{\circ}C$ for 20 min, and sputtering pressure of 20 mTorr.

A Study of Family Caregiver's Burden for the Terminally III Patients (지역사회 말기질환자 가족 부담감에 관한 연구)

  • Han, Sung-Suk;Ro, You-Ja;Yang, Soo;Yoo, Yang-Sook;Kim, Sek-Il;Hwang, Hee-Hyung
    • Journal of Home Health Care Nursing
    • /
    • v.10 no.1
    • /
    • pp.58-72
    • /
    • 2003
  • The purpose of this study was to describe the perceived burden of the terminally III patients's caregiver and to analyze relationship between the perceived burden and the various demographics, illness characteristics, family relationships, and economic factor of the family & patients. The sample of 132 caregivers who care for the terminally III patients Kyung-Gi province, Seoul, Korea. The period of this study was from August to September, 2002. The perceived burden of the family caregiver was measured by the burden scale(20 items, 4 point scale) developed by Montgomery et al. (1985). The Data was analyzed using SAS-program by t-test and ANOVA. The results were as follows; 1. The mean of the family caregiver's burden score was 3.02. The score showed that caregivers perceive severe the level of burden. The hight items of the family caregiver's burden were' I feel it is painful to watch patient's diseases'(3.77). 'I feel afraid for what the future holds for my patients'(3.66), 'I feel it reduced to amount of privacy time'(3.64). 2. The caregiver's burden was significantly related to patient's gender(F=3.17, p= 0.0020), patient's job(F=2.49, p=0.0476), caregiver's age(F=4.29, p=0.0030), and caregiver's job(F=2.49, p=0.0476). 3. The caregiver's burden according to illness characteristics showed no significant difference. 4. The caregiver's burden was significantly associated with patient's family relationship (F=4.05, p=0.0041), patient's care mean period in a day(F=47.18,

  • PDF

A Study on the Synthesis, Labeling and Its Biodistribution of Estradiol Derivatives (에스트라디올 유도체의 합성, 표지 및 체내동태에 관한 연구)

  • Kim, Sang-Wook;Yang, Seung-Dae;Suh, Yong-Sup;Chun, Kwon-Soo;Ahn, Soon-Hyuk;Lim, Soo-Jung;Choi, Chang-Woon;Lim, Sang-Moo;Kim, Young-Soon;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.403-409
    • /
    • 2000
  • Objectives: Due to the heterogeneous receptor distribution and changes of receptor status over time, the biochemical measurement of estrogen receptor status of biopsy specimens is not sufficient to diagnose breast cancer. As a result, I-123 labeled estradiols have been applied for the diagnosis. The purpose of this study was to develop a suitable radioligand for imaging estrogen receptor-positive human breast tumors. Methods: Among the various estradiol derivatives, $17{\alpha}-[^{123}I]$iodovinyl estradiol ($[^{123}I]$IVE) has been prepared from $17{\alpha}$-ethynyl estradiol. Labeling of $E-17{\alpha}-[^{123}I]$iodovinyl estradiol (E-$[^{123}I]$IVE) was carried out using peracetic acid with $[^{123}I]NaI\;and\;Z-[^{123}I]IVE$ labelling was archived using chloamine-T/HCl solution with $[^{123}I]$NaI. Labeling yield was determined by silica thin-layer chromatography (TLC) and radiochemical purity was measured by high performance liquid chromatography (HPLC). The biodistribution of E-$[^{123}I]$IVE was measured in immature female rats at 60 min, 120 min and 300 min after injection. Results: The labeling yield of two isomers was 92% and 94% ($E-[^{123}I]IVE\;and\;Z-[^{123}I]IVE$, respectively). The radiochemical purity was more than 98% after purification. The highest uptake was observed at 120 min in uterus (3.11% ID/g for E-$[^{123}I]$IVE). Conclusion: These results suggest the possibility of using E-$[^{123}I]$IVE as an imaging agent for the evaluation of the evaluation of the presence of estrogen receptor in patients with breast cancer.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

Exploration of optimum conditions for production of saccharogenic mixed grain beverages and assessment of anti-diabetic activity (잡곡당화음료 제조 최적 조건 탐색 및 항당뇨 활성 평가)

  • Lee, Jae Sung;Kang, Yun Hwan;Kim, Kyoung Kon;Yun, Yeong Kyeong;Lim, Jun Gu;Kim, Tae Woo;Kim, Dae Jung;Won, Sang Yeon;Bae, Moo Hoan;Choi, Han Seok;Choe, Myeon
    • Journal of Nutrition and Health
    • /
    • v.47 no.1
    • /
    • pp.12-22
    • /
    • 2014
  • Purpose: This study was conducted to establish the production conditions through optimization of the production process of beverages using Aspergillus oryzae CF1001, and to analyze volatile compounds and antidiabetic activity. Methods: The optimum condition was selected using the response surface methodology (RSM), through a regression analysis with the following independent variables gelatinization temperature (GT, $X_1$), saccharogenic time (ST, $X_2$), and dependent variable; ${\Delta}E$ value (y). The condition with the lowest ${\Delta}E$ value occurred with combined 45 min ST and $50^{\circ}C$ GT. The volatile compounds were analyzed quantitatively by GC-MS. Results: Assessment of antidiabetic activity of saccharogenic mixed grain beverage (SMGB) was determined by measurement of ${\alpha}$-glucosidase inhibition activity, and glucose uptake activity and glucose metabolic protein expression by reverse transcriptase polymerase chain reaction (RT-PCR) and western blot analysis. Results of volatile compounds analysis, 62 kinds of volatile compounds were detected in SMGB. Palmitic acid (9.534% ratio), benzaldehyde (8.948% ratio), benzyl ethyl ether (8.792% ratio), ethyl alcohol (8.35% ratio), and 2-amyl furan (4.826% ratio) were abundant in SMGB. We confirmed that ${\alpha}$-glucosidase inhibition activity, glucose uptake activity, and glucose-metabolic proteins were upregulated by SMGB treatment with concentration dependent manner. Conclusion: Saccharogenic mixed grain beverage (SMGB) showed potential antidiabetic activity. Further studies will be needed in order to improve the taste and functionality of SMGB.

Simulation and Measurement of Signal Intensity for Various Tissues near Bone Interface in 2D and 3D Neurological MR Images (2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기 계산 및 측정)

  • Yoo, Done-Sik
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.33-40
    • /
    • 1999
  • Purpose: To simulate and measure the signal intensity of various tissues near bone interface in 2D and 3D neurological MR images. Materials and Methods: In neurological proton density (PD) weighted images, every component in the head including cerebrospinal fluid (CSF), muscle and scalp, with the exception of bone, are visualised. It is possible to acquire images in 2D or 3D. A 2D fast spin-echo (FSE) sequence is chosen for the 2D acquisition and a 3D gradient-echo (GE) sequence is chosen for the 3D acquisition. To find out the signal intensities of CSF, muscle and fat (or scalp) for the 2D spin-echo(SE) and 3D gradient-echo (GE) imaging sequences, the theoretical signal intensities for 2D SE and 3D GE were calculated. For the 2D fast spin-echo (FSE) sequence, to produce the PD weighted image, long TR (4000 ms) and short TE$_{eff}$ (22 ms) were employed. For the 3D GE sequence, low flip angle (8$^{\circ}$) with short TR (35 ms) and short TE (3 ms) was used to produce the PD weighted contrast. Results: The 2D FSE sequence has CSF, muscle and scalp with superior image contrast and SNR of 39 - 57 while the 3D GE sequence has CSF, muscle and scalp with broadly similar image contrast and SNR of 26 - 33. SNR in the FSE image were better than those in the GE image and the skull edges appeared very clearly in the FSE image due to the edge enhancement effect in the FSE sequence. Furthermore, the contrast between CSF, muscle and scalp in the 2D FSE image was significantly better than in the 3D GE image, due to the strong signal intensities (or SNR) from CSF, muscle and scalp and enhanced edges of CSF. Conclusion: The signal intensity of various tissues near bone interface in neurological MR images has been simulated and measured. Both the simulation and imaging of the 2D SE and 3D GE sequences have CSF, fat and muscle with broadly similar image intensity and SNR's and have succeeded in getting all tissues about the same signal. However, in the 2D FSE sequence, image contrast between CSF, muscle and scalp was good and SNR was relatively high, imaging time was relatively short.

  • PDF

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

The Survey for Improvement in Clinical Practice Curriculum of Physiotherapy (물리치료 임상실습 교과내용 개선을 위한 조사연구)

  • Jang, Su-Gyeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.3
    • /
    • pp.659-674
    • /
    • 1998
  • This Study was to investigate elaborated research themes and direction through specifying the problems of clinical practice education and looking for the direction of improvement. It was in the basis of the viewpoint of the educators that professors and therapists who were the subjects of this study. Perform this study, the 15 colleges' professors and the 55 hospitals' therapists was made up questionnaire, and the data was analysing by Chi-square test and percentage. The results were as follow : ${\cdot}$ In a personal history among the general qualities, professors have little clinical practice history(l-5 years, 53.3%), and therapists have little lecture career(1-5 years, 43.6%, have no 49.0%), ${\cdot}$ The 78.6% subjects were unsatisfied of clinical practice systems. ${\cdot}$ The correlation between clinical history, school career and lecture career and the satisfaction level of clinical practice systems has no(P<.005), ${\cdot}$ The subjects were agreed to that clinical practice curriculum should be changed(67.1%), reinforced(82.9%), and specified(90.0%). ${\cdot}$ The clinical practice credits are 11 points averagely. ${\cdot}$ In the clinical practice curriculum, it made no difference in the practicum of diseases, modality, and the therapeutic techniques between professors and therapists. ${\cdot}$ The 100% professors said that the practicum of the patients' assessment is necessary, and the 63.6% therapists were training for that. ${\cdot}$ The 66.7% professors said that the practicum of the clinical psychology is necessary, and only the 20.0% therapists were training for that. ${\cdot}$ The 93.3% professors said that the practicum of the patients' management is necessary, and the 50.9% therapists were training for that. ${\cdot}$ The 66.7% professors said that the practicum of the medical ethics is necessary, and the 34.5% therapists were training for that. ${\cdot}$ The 46.7% professors said that the practicum of the hospital administration is necessary, but the 54.5% therapists have not training. ${\cdot}$ The 33.3% professors said that the practicum of the pharmacology is necessary, but the 81.8% therapists have not training. ${\cdot}$ The 86.7% professors said that the practicum of the patient's education is necessary, and the 43.6% therapists have training. ${\cdot}$ The 66.7% professors said that the practicum of the prosthesis and brace is necessary, but the 14.5% therapists have not training. ${\cdot}$ The 60.0% professors said that the practicum of the exercise prescription is necessary, but the 25.5% therapists have not training. ${\cdot}$ The 53.5% professors said that the practicum of the emergency treatment is necessary, but the 52.7% therapists have not training. ${\cdot}$ Drawing up the plan about the curriculum of clinical practice, the professors (46.7%) were agreed to national master plan framing by an expert advisor, but the therapists (58.2%) said that the plan that make the most of hospitals' characteristics should be specified. ${\cdot}$ It was found that a clinical special therapists(54.5%) was good as a person in charge of clinical practice education, in that each therapist's own good time (34.5%) was. ${\cdot}$ It made use of the form framing by college(40.0%) as the clinical practice textbook, the form framing by hospital (42.9%) and each therapist(22.9%) as the plan, and the form framing by college (74.3%) as the measurement. ${\cdot}$ The most difficult point in clinical practice education was the lacks of the theory-praciticum linkage(78.2%). ${\cdot}$ It was found that the period of clinical practice was in the second semester-third grade (40.0%) and the desirable period was in the first semester-third grade(50.0%). ${\cdot}$ Professors (53.3%) were agreed that the desirable clinical practice duration was from four months to six months(60.0%), and the therapists (60.0%) were agreed that from one month to three months. ${\cdot}$ This study presented the lacks of rearing the experts, the lacks of cultural education, and the lacks of the theory-clinical practice linkage. There were need to develop the systematic programs, clinical practice textbooks, the measurements and the special hospital for clinical practice. And it was need to reduce the gab between of the hospitals for clinical practice, to cut down the costs. and to improve the labour conditions of leaders. In view of this findings, it takes notice of that both professor and therapist were dissatisfied at the present clinical practice systems. These results point out the problems of clinical practice systems, and do not make expect to us the successive and positive clinical practice. The general, specific and intensive plan about the problems and the direction of improvement that establishing the level of hospital for clinical practice and physiotherapy can be elaborated.

  • PDF