• Title/Summary/Keyword: measurement table

Search Result 455, Processing Time 0.03 seconds

Post-earthquake fast building safety assessment using smartphone-based interstory drifts measurement

  • Hsu, Ting Y.;Liu, Cheng Y.;Hsieh, Yo M.;Weng, Chi T.
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.287-299
    • /
    • 2022
  • Rather than using smartphones as seismometers with designated locations and orientations, this study proposes to employ crowds' smartphones in buildings to perform fast safety assessment of buildings. The principal advantage of using crowds' smartphones is the potential to monitor the safety of millions of buildings without hardware costs, installation labor, and long-term maintenance. This study's goal is to measure the maximum interstory drift ratios during earthquake excitation using crowds' smartphones. Beacons inside the building are required to provide the location and relevant building information for the smartphones via Bluetooth. Wi-Fi Direct is employed between nearby smartphones to conduct peer-to-peer time synchronization and exchange the acceleration data measured. An algorithm to align the orientation between nearby smartphones is proposed, and the performance of the orientation alignment, interstory drift measurement, and damage level estimation are studied numerically. Finally, the proposed approach's performance is verified using large-scale shaking table tests of a scaled steel building. The results presented in this study illustrate the potential to use crowds' smartphones with the proposed approach to record building motions during earthquakes and use those data to estimate buildings' safety based on the interstory drift ratios measured.

Concept Development of a Simplified FPGA based CPCS for Optimizing the Operating Margin for I-SMRs

  • Randiki, Francis;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • The Core Protection Calculator System (CPCS) is vital for plant safety as it ensures the required Specified Acceptance Fuel Design Limit (SAFDL) are not exceeded. The CPCS generates trip signals when Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) exceeds their predetermined setpoints. These setpoints are established based on the operating margin from the analysis that produces the SAFDL values. The goal of this research is to create a simplified CPCS that optimizes operating margin for I-SMRs. Because the I-SMR is compact in design, instrumentation placement is a challenge, as it is with Ex-core detectors and RCP instrumentation. The proposed CPCS addresses the issue of power flux measurement with In-Core Instrumentation (ICI), while flow measurement is handled with differential pressure transmitters between Steam Generators (SG). Simplification of CPCS is based on a Look-Up-Table (LUT) for determining the CEA groups' position. However, simplification brings approximations that result in a loss of operational margin, which necessitates compensation. Appropriate compensation is performed based on the result of analysis. FPGAs (Field Programmable Gate Arrays) are presented as a way to compensate for the inadequacies of current systems by providing faster execution speeds and a lower Common Cause Failure rate (CCF).

Geometric error assessment system for linear guideway using laser-photodiodes (레이저-수광소자를 이용한 선형 이송측의 기하학적 오차측정 시스템)

  • Pahk, H.J.;Chu, C.N.;Hwang, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.180-188
    • /
    • 1994
  • Error assessment and evaluation for machine for machine tool slides have been considered as essential tools for improving accuracy. In this paper, a computer aided measurement technique is proposed using photo pin diodes of quadrant type and laser source. In thedeveloped system, three photo diodes are mounted on a sensor mounting table, and the sensored signal is processed by specially designed signal conditioner to give fine resolution with minimum noise. A micro computer inputs the processed signal, and the geometric errors of five degree of freedoms are successfully evaluated. Pitch, roll, yaw, vertical and horizontal straightness errors are thus assessed simultaneously for a machine tool slide. Calibration techniques such as optics calibration, photo diode calibration are proposed and implemented, giving precise calibration for the measurement system. The developed system has been applied to a practical machine tool slide, and has been found as one of efficient and precise technique for machine tool slide.

  • PDF

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

The improvement of Quality of Observed Values II ${\sim}$Detection Limit${\sim}$

  • Maruyama Yukio;Miyazu Takashi
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.378-383
    • /
    • 1998
  • Needless to say, the importance of the quality of observed values shall be emphasized in the field of 'TQM', because, the first step of 'TQM' should be some data - observed values. Usually, meaning of the quality of observed values should be, a) accuracy (trueness and precision), b) detection limit, c) cost and so on. However, the authors will describe mainly on b), in this paper. The definitions of technical terms related to 'Detection Limit' are defined in ISO l1843-1 Capability of detection - Part1:Terms and definitions (1998). The most important terms extracted from the above standard are shown in the following table. The application of the 'Detection Limit' to the actual measurement is discussed in this paper.

  • PDF

A Study on Application of the Korea Human Scale to Anthropometric Design

  • Lee, Dhong-Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.211-217
    • /
    • 2012
  • Objective: The aim of this study is to show a correct application procedure using the compact Korean anthropometric data application program called Korean Human Scale(KHS) for anthropometric design. Background: The nation-wide anthropometric survey project called 'Size Korea' developed KHS and distributed it to the public on the web site. But some insufficiency of the current web service of KHS misleads the users; they just put their own statue and pick up a meaningless data for a body dimension. Method: This study provides five steps to follow to read appropriate data from KHS for an anthropometric design. Results: As a case study, the depth dimension of the supervisory and control console used in the Korea nuclear power plant was determined following the procedure and compared with the console design guideline recommendation. Conclusion: The supplementary anthropometry table should be added on the web service of KHS for users to read a meaningful data for design. Application: If properly used, the KHS has a lot more potential application area than users can expect such as in control center design area.

Experimental Study of Relation between Air exclusion & Quality of the Concrete (공기 침투성과 콘크리트 품질의 상관관계에 관한 실험적 연구)

  • 박성우;윤성훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.685-691
    • /
    • 2002
  • Air exclusion test which is the way to assess the quality of the concrete is a part destructive test for minor damaging and accurate measurement. it has been well known but the test process is complexed, so it has been well known in foreign country but it is not usable in our country. For this experiment, it analyze its special quality through the inspection for the factor which effect to the result or accuracy for the Air exclusion test, and it examine through the experiment for the Non destructive test and cylinder compressive test which is different from the air exclusion test. We suggest the suitable classified table for the domestic concrete condition through the comparative analysis against the overseas result that has been suggested before.

  • PDF

User Process Resource Usage Measurement for Grid Accounting System

  • Hwang Ho Jeon;Kim Beob Kyun;Doo Gil Su;An Dong Un;Chung Seung Jong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.608-611
    • /
    • 2004
  • Grid computing environment can be used to interconnect a wide variety of geographically distributed heterogeneous computing resources based on high-speed network. To make business service, it is necessary for Grid accounting system to measure the computational cost by consuming computer resources. To collect resource consumption data, and to keep track of process without needing to recompile kernel source, we use system call wrapping. By making use of this technique, we modifies system call table and replace existing system call to new system call that can monitor processes running in CPU kernel currently. Therefore we can measure user process resource usage for Grid accounting system.

  • PDF

A Development of the Digital Swithchgear using the Microprocessor (마이크로 프로세서를 이용한 전자식 배전반 개발)

  • Byun, Young-Bok;Joe, Ki-Youn;Koo, Heun-Hoi;Kim, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.375-379
    • /
    • 1990
  • A microprocessor-based multi-function switchgear for the protection, measurement and control of the power system is presented. For the extraction of the RMS values of the fundamental components of current and voltage signals, a simple digital filter based on cross-correlation of the distorted signal with even and odd heptagonal waves is used. The frequency response of this filter is almost identical to that of the filter based on the discrete fourier transform, while its computational requirement is far less. For the time delay element relaying, a new log-table based relaying algorithm is suggested. The suggested use of the heptagonal wave cross-correlation digital filter algorithm and a new relaying algorithm reduce the computational needs so drastically that all functions of the switchgear can be implemented on the microprocessor system. Real time testing of the implemented daboratory prototype show good practical response under different operating conditions.

  • PDF

A Study on Performance of Linear Motor for Machine Tools (공작기계용 리니어모터의 운동성능 평가에 관한 연구)

  • 최헌종;강은구;정일용;이석우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.215-220
    • /
    • 2002
  • Recently, linear motor has been developed for linear motion of machine tools. Linear motor is useful to design the linear motion, high speed and high accuracy, because of the simple system not required the additional mechanical part such as coupling and ballscrew. This paper tested performance of linear motor relevant to motioning and positioning table such as F.R.F., step response and positional accuracy Linear motion system using linear motor requires the effective cooling system because it cause to decrease the positional error and to protect the motor coil. Therefore the positional error measurement was made to evaluate the effect of the temperature variation.

  • PDF