• Title/Summary/Keyword: measurement interval

검색결과 689건 처리시간 0.021초

컴퓨터 정액자동분석에 의한 동결융해 한우 정액의 운동특성 연구 (Motional kinematics of Frozen-thawed Korean native cattle semen use of computer aided semen analysis(CASA) system)

  • 이강남;이병천;김정태;박종임;신태영;황우석
    • 대한수의학회지
    • /
    • 제38권4호
    • /
    • pp.898-908
    • /
    • 1998
  • The aim of this experiments were to assess the time-interval change of motional characteristics in frozen-thawed semen of Korean native cattle (KNC) by using computer aided semen analysis (CASA) technology. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system (SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber (Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The measurement parameters in SIAS were as follows ; frame rate = 30 frames per sec, image capture = 1 sec, minimum motile speed = $10{\mu}m/s$, maximum countable sperm number = 400. Statistical analysis was done by Student t-test with use of the Sigma plot program on a IBM personal computer. The dancemean(DNM) and hyperactivated sperm(HYP) of frozen-thawed KNC semen kinematics were significantly decreased(p < 0.05) after 10 min of incubation at $37^{\circ}C$ water bath. But, wobble(WOB) of same sample semen was significantly increased(p < 0.05) after 10 min of incubation and significantly decrease(p < 0.05) after 60 min of same incubation. And, after 30 mim of incubation, significantly differences were found most of motion kinematics, motifity(MOT), curvilinear velocity(VCL), straight line velocity(VSL), average path velocity(VAP), amplitude of lateral head displacement(ALH), beat cross frequency(BCF), mean angular displacement(MAD), dance(DNC), on same sample semen. The DNM of KNC semen sample was variable kinematics after 30 min of incubation. Also, the linearity(LIN) and straightness(STR) was significantly decreased(p < 0.05) from 60 min of incubation. In conclusion, the AI within 30 min after thawing of frozen semen can be an effective method for obtaining high fertility rate in KNC reproductive program.

  • PDF

개인 창의성이 지식공유와 혁신행동에 미치는 영향: 유통업 종사자를 중심으로 (The Effect of Personal Creativity on Knowledge Sharing and Innovation Behavior: Focused on Retail Workers)

  • 이준표;박계홍
    • 유통과학연구
    • /
    • 제17권10호
    • /
    • pp.93-105
    • /
    • 2019
  • Purpose - First, empirical research will reveal how personal creativity affects the knowledge sharing and innovation behaviors of organizational members. Second, self-management competency will be verified to explain the causal relationship between independent and dependent variables as a mediating variable and to reduce the time interval. Research design, data, and methodology - There are two major research models. First, personal creativity (professionalism, emotional intelligence, internal motivation) has a positive impact on knowledge sharing (creation of knowledge, organization of knowledge, use of knowledge) and innovation behavior (deriving ideas, implementing ideas, promoting ideas). Second, self-management competency (intellectual capacity, emotional capacity, personality capacity) plays a mediating role. In addition to descriptive statistics and correlation analysis, Cronbach's α was calculated for 259 workers in the retail industry. In addition, confirmatory factor analysis was performed using the AMOS 24.0 program, and the influence on the measurement model was analyzed to verify the structural equation model. Results - First, personal creativity had a positive effect on knowledge sharing and innovation behavior. In other words, it was confirmed that the decision-making process accompanied by individual creativity can create an atmosphere of knowledge sharing and continue to innovate. Second, personal creativity had a positive effect on self-management competency, and self-management competency had a positive effect on knowledge sharing and innovation behavior. Third, self-management competency was found to partially mediate the influence of personal creativity on knowledge sharing and innovation behavior. Conclusions - First, it is important for managers to recognize the value of creative talents who can be a fundamental source of organizational success and competitive advantage, and to attract talented people. Second, managers should be able to develop decision-making processes to develop potential creativity and encourage creative ideas, opinions, or solutions when organizing the work environment of their members. Third, managers should promote the sharing and integration of new knowledge that underlies the creative views and attitudes of teams and organizational members. Unlike previous studies, which emphasize the role of the work environment in which creative behaviors are promoted, this study shows that creativity of individual members, itself, is an important determinant of knowledge sharing and innovation behavior.

MRI에 의한 한국인 신체분절의 생체역학적 모수치 산출 (Employing Magnetic Resonance Imaging(MRI) in the Estimation of the Biomechanical Body Segment Parameters of Korean Adults)

  • 주영화
    • 한국운동역학회지
    • /
    • 제12권1호
    • /
    • pp.233-249
    • /
    • 2002
  • The purpose of this study was to employing MRI in the estimation of the biomechanical body segment parameters of Korean adults. for this purpose MRI study on 19 Korean living subjects were used to measurement. All the parameters that was concerned were inertial characteristics of human body mass of each segment, center of mass of them and the length of radius of gyration of them. The cross sectional images and saggital images of every 1cm interval were got using the 0.5 Tesla MRI from the top of head to the bottom of foot, whole body. And then, by tracing the images of the film and scanning them, got the area which the several tissues occupied in the image of slice. By summing the area of slice of each segment which were calculating and by multipling the density of the tissues, got the mass of segment and other inertial characteristics. The ratios of radius of gyration in both transverse axis and longitudinal axis though the segmental mass and segment length are as follow: male A : head($0.229\pm0.0029$), neck($0.256\pm0.0095$), thorax($0.374\pm0.0059$) abdomen($0.245\pm0.0020$), pelvis($0.368\pm0.0106$), thigh($0.288\pm0.0030$) shank($0.280\pm0.0043$), foot($0.277\pm0.0195$), upperarm($0.311\pm0.0074$) forearm($0.286\pm0.0051$), hand($0.253\pm0.0095$) female A : head($0.214\pm0.0032$), neck($0.254\pm0.0112$), thorax($0.295\pm0.0061$) abdomen($0.289\pm0.0021$), pelvis($0.329\pm0.0108$), thigh($0.288\pm0.0036$) shank($0.280\pm0.0047$), foot($0.243\pm0.0206$), upperarm($0.279\pm0.0083$) forearm($0.286\pm0.0048$), hand($0.229\pm0.0097$) male B : head($0.532\pm0.0006$), neck($0.533\pm0.0006$), thorax($0.658\pm0.0008$) abdomen($1.350\pm0.0022$), pelvis($0.875\pm0.0002$), thigh($0.213\pm0.0001$) shank($0.160\pm0.0001$), foot($0.152\pm0.0002$), upperarm($0.136\pm0.0002$) forearm($0.202\pm0.0002$), hand($0.273\pm0.0006$) female B : head($0.198\pm0.0002$), neck($0.335\pm0.0011$), thorax($0.238\pm0.0001$) abdomen($0.888\pm0.0001$), pelvis($1.318\pm0.0117$), thigh($0.095\pm0.0001$) shank($0.075\pm0.0001$), foot($0.181\pm0.0006$), upperarm($0.0.062\pm0.0001$) forearm($0.083\pm0.0001$), hand($0.105\pm0.0007$).

손상 모발을 위한 EPA 함유 샴푸 개발 (Development of Shampoo Formulated by EPA for the Damaged Hair)

  • 이보름;이옥상;강태진;임성실
    • 한국임상약학회지
    • /
    • 제21권3호
    • /
    • pp.256-269
    • /
    • 2011
  • Omega-3 fatty acids are a specific type of unsaturated fat that the body cannot manufacture on its own, so they must be obtained from food which is essential fatty acids (EFAs). Omega-3 fatty acids consist of three types which are a-Linolenic Acid (ALA), Eicosapentaenoic (ELA), and Docosahexaenoic Acid (DHA). Especially, EFAs help to prevent skin and hair drying, acne, eczema, prevention from allergies, brittle nails, rashes, and tiny lumps. The aim of this study is to investigate improvement and protection for hair damaged by chemical treatment with omega-3 formulated shampoo. We selected virgin hair sample and divided into two groups for bleaching once and three times and then damaged hair by changing the number of hair bleaching (twice with interval of 15 minutes). Each bleached hair was treated by five different kinds of shampoo (Control, Horse shampoo, DHA shampoo, EPA shampoo, Omega-3 shampoo mixture). Apart from this, EPA/DHA 2, 5, 8, 10 and 12% shampoo were prepared and treated to hair for comparing rate of progress in damaged hair. To quantify improved condition of damaged hair, we performed Scanning Electron Microscope (SEM) for ultrastructure of damaged hair fraction, measurement of thickness change and BCA Protein Assay for recovery rate of damaged hair. The moisture in hair was measured by Thermal analysis machine. In results, we observed the particle of hair surface damaged by bleaching treatment were well improved with treatment with EPA and DHA shampoo. Also, quantity of protein was lowered with higher concentration of EPA & DHA i.e., 8 and 12 % then compared with horse oil shampoo in three times treatment group. It shows that bleached hair have been recovered by treating rapidly and get protective coat. In conclusion, EPA and DHA shampoo improved damaged hair, especially with EPA / DHA 12% shampoo. Also, EPA shampoo could protect the damaged hair depending on increasing concentration of EPA. Therefore, we conclude omega-3 shampoo could make damaged hair protect and get healthy hair environment.

Exhaled Nitric Oxide in Patients with Stable Chronic Obstructive Pulmonary Disease: Clinical Implications of the Use of Inhaled Corticosteroids

  • Jo, Yong Suk;Choe, Junsu;Shin, Sun Hye;Koo, Hyeon-Kyoung;Lee, Won-Yeon;Kim, Yu Il;Ra, Seung Won;Yoo, Kwang Ha;Jung, Ki Suck;Park, Hye Yun;Park, Yong-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권1호
    • /
    • pp.42-50
    • /
    • 2020
  • Background: Fractional exhaled nitric oxide (FeNO) is regarded as a potential biomarker for identifying eosinophilic inflammation. We aimed to evaluate the clinical implication of FeNO and its influence on inhaled corticosteroids (ICS) prescription rate in Korean chronic obstructive pulmonary disease (COPD) patients. Methods: FeNO level and its association with clinical features were analyzed. Changes in the prescription rate of ICS before and after FeNO measurement were identified. Results: A total of 160 COPD patients were divided into increased (≥25 parts per billion [ppb], n=74) and normal (<25 ppb, n=86) FeNO groups according to the recommendations from the American Thoracic Society. Compared with the normal FeNO group, the adjusted odds ratio for having history of asthma without wheezing and with wheezing in the increased FeNO group were 2.96 (95% confidence interval [CI], 1.40-6.29) and 4.24 (95% CI, 1.37-13.08), respectively. Only 21 out of 74 patients (28.4%) with increased FeNO prescribed ICS-containing inhaler and 18 of 86 patients (20.9%) with normal FeNO were given ICS-containing inhaler. Previous exacerbation, asthma, and wheezing were the major factors to maintain ICS at normal FeNO level and not to initiate ICS at increased FeNO level. Conclusion: Increased FeNO was associated with the history of asthma irrespective of wheezing. However, FeNO seemed to play a subsidiary role in the use of ICS-containing inhalers in real-world clinics, which was determined with prior exacerbation and clinical features suggesting Th2 inflammation.

The Usefulness of Selected Physicochemical Indices, Cell Membrane Integrity and Sperm Chromatin Structure in Assessments of Boar Semen Sensitivity

  • Wysokinska, A.;Kondracki, S.;Iwanina, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제28권12호
    • /
    • pp.1713-1720
    • /
    • 2015
  • The present work describes experiments undertaken to evaluate the usefulness of selected physicochemical indices of semen, cell membrane integrity and sperm chromatin structure for the assessment of boar semen sensitivity to processes connected with pre-insemination procedures. The experiments were carried out on 30 boars: including 15 regarded as providers of sensitive semen and 15 regarded as providers of semen that is little sensitive to laboratory processing. The selection of boars for both groups was based on sperm morphology analyses, assuming secondary morphological change incidence in spermatozoa as the criterion. Two ejaculates were manually collected from each boar at an interval of 3 to 4 months. The following analyses were carried out for each ejaculate: sperm motility assessment, sperm pH measurement, sperm morphology assessment, sperm chromatin structure evaluation and cell membrane integrity assessment. The analyses were performed three times. Semen storage did not cause an increase in the incidence of secondary morphological changes in the group of boars considered to provide sperm of low sensitivity. On the other hand, with continued storage there was a marked increase in the incidence of spermatozoa with secondary morphological changes in the group of boars regarded as producing more sensitive semen. Ejaculates of group I boars evaluated directly after collection had an approximately 6% smaller share of spermatozoa with undamaged cell membranes than the ejaculates of boars in group II ($p{\leq}0.05$). In the process of time the percentage of spermatozoa with undamaged cell membranes decreased. The sperm of group I boars was characterised with a lower sperm motility than the semen of group II boars. After 1 hour of storing diluted semen, the sperm motility of boars producing highly sensitive semen was already 4% lower ($p{\leq}0.05$), and after 24 hours of storage it was 6.33% lower than that of the boars that produced semen with a low sensitivity. Factors that confirm the accuracy of insemination male selection can include a low rate of sperm motility decrease during the storage of diluted semen, low and contained incidence of secondary morphological changes in spermatozoa during semen storage and a high frequency of spermatozoa with undamaged cell membranes.

광섬유센서케이블을 이용한 지하연구시설의 지반변위 및 온도변화 감시시스템 구축 (Monitoring System of Rock Mass Displacement and Temperature Variation for KURT using Optical Sensor Cable)

  • 김경수;배대석;고용권;김중열
    • 지질공학
    • /
    • 제19권1호
    • /
    • pp.63-70
    • /
    • 2009
  • 한국원자력연구원 내에 위치하는 지하연구시설의 안정적인 운영을 위하여 터널 내 벽면과 주변 사면의 지반변위 및 온도 변화를 실시간 감시할 수 있는 시스템을 구축하였다. 이 시스템은 광섬유센서케이블의 센서 기능을 활용하여 케이블 전체가 하나의 센서 기능을 하는 분포개념의 온도 및 변형을 측정기법을 이용한 것으로서 기존의 특정지점 계측방법과는 확연하게 차별된다. 이 기법은 구조물의 특성에 따라 선택적으로 탄력적 적용이 가능하여, 최대 매 1 m 간격으로 총연장 30 km까지 하나의 운영체계로 감시할 수 있는 기능을 가지고 있다. 변형특성의 계측 범위는 1 m 당 1 mm 변위 크기까지 계측이 가능하며, 변위 발생 위치와 변위가 진행하는 방향까지 계측 가능하다. 온도는 $0.01^{\circ}C$ 해상도를 가지며 케이블 종류에 따라 $-160{\sim}600^{\circ}C$까지 계측이 가능하다. 지하연구시설에서 1년 간의 모니터링 결과, 터널 벽면 및 주변 사면에서 뚜렷한 변위 혹은 거동은 확인할 수 없었으나, 지하수 누출에 의해 점진적으로 영향이 미칠 것으로 예상되는 징후를 확인하였다. 이로서 숏크리트로 처리한 터널 벽면의 균열변형 및 붕괴/낙반사고를 사전에 감지하고, 암반 내 지하수위의 등락과 함께 연구 터널내 환기상태를 감시, 관리할 수 있는 시스템을 구축하게 되었다. 이 외에도 이 시스템은 복잡한 구조를 갖는 플랜트의 변형은 물론 장대 구조물과 고층빌딩, 대형선박, 장대 교량, 댐과 송수관로 및 지하철 등의 안전 유지상태 및 누수 등의 감시에도 적용 가능하다. 특히 온도 변화 감시 기능은 목재 건조물에도 효과적으로 이용할 수 있다.

대기 에어로졸 검댕입자 측정을 위한 두 aethalometer의 상호비교 (Inter-comparison of Two Aethalometers for Aerosol Black Carbon Measurements)

  • 정정훈;박승식;윤관훈;조성용;김승재
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.201-208
    • /
    • 2011
  • Recently, a real-time, pocket-sized aethalometer (microAeth$^{(R)}$ model AE51) has been developed by Magee Scientific Inc. for measuring the concentration of black carbon in the atmosphere. In this study, two aethalometers, models AE-16 and AE-51, which measure the optical absorption of carbon particles at infrared 880 nm, were operated at time interval of 5-min between January 9 and February 10, 2010 at an urban site of Gwangju, to compare the accuracy of black carbon (BC) concentrations reported from the AE-51 model and to investigate reasonable sampling time of filter media in the AE-51. The air samples in the AE-51 and AE-16 models are collected on T60 (Teflon coated glass fiber) filter media (filter spot area: 0.07 $cm^2$) and quartz fiber roll-tape filter (filter spot area: 1.67 $cm^2$), respectively. Real-time measurement results indicate that when the filters were clean, the AE-51 BC was greater than or similar to the AE-16 BC data. However as the filter spots become darker, the AE-16 BC concentrations were higher than the AE-51 BC data and the difference in the BC concentrations from two AE models becomes gradually increased. Relative error in the AE-51 and AE-16 BC concentrations showed significance difference depending on used time of the filter in the AE-51 model, weather pattern, levels of air pollution, etc, ranging from 11.5% (used time of the filter in AE-51: 1,595 min) to 52.5% (used time of the filter in AE-51: 2,085 min). When considering the used time of one filter ticket in the AE-51 model and difference (or relative error %) between AE-16 and AE-51 BC concentrations, it is recommended that the standard sampling time per one filter ticket within the AE-51 model be less than approximately 24 hr (1,440 min) under the normal weather conditions except for severe haze and mist events.

고용량 옥소 치료 시 3차원적 공간선량률 측정 및 연구 (The Study and Measurement of Three Dimensional Spatial Dose Rate from Radioiodine Therapy)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.251-257
    • /
    • 2013
  • 고용량 옥소 치료 시 수평면, 수직면, 방위각에 따라 3차원적으로 방출되는 공간선량률을 측정하였다. 정확한 측정을 위해 기하학적 구조의 알루미늄 틀을 제작하여 100 cm 거리에서, 높이 (5 측정점), 방위각 (8 측정점), 시간적 간격 (6 측정점)을 각각 나누어서 분석하였다. 수직면상 공간선량률 분포는 $^{131}I$을 경구 투여 24 시간 후 환자로부터 거리 100 cm, 높이 100 cm 지점에서 환자군 평균 71.85 ${\mu}Sv/h$로 가장 높았다. 수분섭취를 통한 공간선량률 감쇠 정도를 두 그룹으로 나누어 실험하였다. $^{131}I$을 경구 투여 24시간 뒤 거리 100 cm, 높이 100 cm에서 공간선량률 분포가 A 실험군은 44.9 ${\mu}Sv/h$이고 B 실험군은 100.28 ${\mu}Sv/h$이다. A 실험군이 B 실험군과 비교하여 고용량 옥소 치료 시 수분섭취 정도에 따라 약 53 %의 피폭경감 효과를 확인하였다.

만성적 소음노출과 혈압의 상관성에 관한 메타분석 (A Meta-analysis on the Association between Chronic Noise Exposure and Blood Pressure)

  • 김춘배;김재용;차봉석;최홍렬;이종태;남정모;이상윤;왕승준;박기호;김대열;고상백
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권3호
    • /
    • pp.343-348
    • /
    • 2000
  • Objectives : This study was conducted to integrate the results of studies assessing the association between chronic noise exposure and blood pressure. Methods : Using a MEDLINE search with noise exposure, blood pressure and hypertension as key words, we retrieved articles from the literature that were published from 1980 to December 1999. The criteria for quality evaluation were as follows: 1) the study subjects must have been workers employed at a high noise level area 2) The paper should use average and cumulative noise exposure as method for exposure evaluation. 3) Blood pressure in each article should be reported in a continuous scale Among the 77 retrieved articles, six studies were selected for quantitative meta-analysis. Before the integration of the regression coefficients for the association between blood pressure and noise level, homogeneity tests were conducted. Results : All studies were a cross-sectional design and the study subjects were industrial workers. Five papers used a time-weighted average for noise exposure and only one paper calculated the cumulative noise exposure level. The measurement of blood pressure in the majority of studios were accomplished in a resting stale, and used an average of two or more readings. The homogeneity of studies was rejected in a fixed effect model, so we used the results in a random effect model. The results of the quantitative meta-analysis, the weighted regression coefficient of noise associated with systolic blood pressure and diastolic blood pressure were 0.05 (95% confidence interval [CI]: -0.03, 0.13) and 0.06 (95% CI: -0.01, 0.13), respectively. Conclusions : Our results suggested that chronic exposure to industrial noise does not cause elevated blood pressure.

  • PDF