• Title/Summary/Keyword: measurement interval

Search Result 692, Processing Time 0.026 seconds

Straightness Measurement Error Compensation of the Laser Interferometer (레이저 간섭계의 진직도 측정오차 보상)

  • 김경호;김태호;송창규;이후상;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.114-118
    • /
    • 2001
  • HP Laser Interferometer Measurement System[HP5529A] is one of the most powerful equipment for measurement of the motion accuracy. The straightness measurement system of the HP5529A is composed of wollastone prism and reflector. In this system, straightness error is measured by relative lateral motion between prism and reflector. But rotating motion of prism or reflector as moving optic causes not real straightness error but additive straightness error. Especially unwanted straightness error as this becomes very large when reflector is used as moving optic and an interval between reflector and prism is distant. In this paper, the compensation method is proposed for removing additive error and experiment is carried out for theoretical verification.

  • PDF

Heart beat interval measurement using an IBM PC (IBM PC를 이용한 심장 박동 간격의 측정)

  • 이동하;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.3-14
    • /
    • 1990
  • This article develops a cost-effective and accurate measurement system for heart best intervals. The system is composed of an analog to digital (A/D) converter, an IBM personal computer (an 8088 microprocessor, an 8253-5 timer, an 8259A interrupt controller, and memories) and assembler programs for controlling these hardware components. An exponential smoothing algorithm effectively reduced noise effects from A/D converted electrocardiogram (ECG) signals influenced by 60 Hz alternating current (AC). The system can collect 15000 heart beat intervals with an 1/5400 second unit.

  • PDF

A Study on Quality Improvement by Evaluation and Application of GUM-based Measurement Uncertainty (GUM 기반 측정불확도의 평가 및 적용에 의한 품질개선)

  • Insoo Choi;Sun Hur
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.419-434
    • /
    • 2023
  • Purpose: Measurement results obtained under non-ideal measurement environment conditions may contain uncertain factors. As a result, the reliability of measurement results may be deteriorated. In this study, we tried to find ways to improve quality by evaluating and applying measurement uncertainty based on GUM. Methods: In the flatness measurement of semiconductor parts, uncertainty factors that could occur under actual environmental conditions of workers were derived, and measurement uncertainties were calculated, and methods for minimizing the main factors affecting the measurement results were analyzed. Results: Depending on the part and the coordinate measuring machine, it was shown that the effect of dispersion caused by repeated measurements as type A uncertainty and the effect of the calibration results of equipment as type B uncertainty have the main influence. Conclusion: Depending on the uncertainty factors of type A and type B and the influence of the total expanded uncertainty, the central value and confidence interval of the initial measurement results showed fluctuations. It is considered that analysis and measures for the main uncertainty factors are needed as quality improvement in the industrial field.

A Study on Measurement and Automation Method of Cylinder Head Swirl (실린더 헤드 스월 측정 및 자동화 방법에 관한 연구)

  • Lee Choong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.92-99
    • /
    • 2006
  • The swirl ratio of a charge in the cylinder was estimated by calculating the ratio of the rotary speed of charge which could be simulated from the rotary speed of paddle in the swirl measurement apparatus, to the engine speed which could be calculated by measuring intake air flow rate. The automation of the swirl ratio measurement for cylinder head was achieved by controling both valve lift in cylinder head and a suction pressure of surge tank using two step-motors. The number of measurement position for calculating mean swirl ratio was varied by adjusting the interval of valve lift. The mean swirl ratio with varying the number of measurement position showed nearly constant value. Two measurement methods for measuring the swirl ratio were compared, one was to control the suction pressure of the surge tank with PID (proportional, integral, differential) mode with by-pass valve controlled by the step motor and the other did not control the surge tank pressure by fixing the by-pass valve. The difference of the mean swirl ratio between the two measurement methods showed nearly constant value with varying the number of measurement position. This means that the w/o PID control method could be preferred to the PID control method which has been used, due to the simpleness of the swirl measurement.

Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement (식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정)

  • Park, Sang-Wook;Kim, Hyung Bum;Kim, Kwang Joon;Lee, Wonjae
    • KSBB Journal
    • /
    • v.32 no.1
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

Round Robin Test for Reliability Evaluation of Ultrasonic Thickness Measurement Results in Nuclear Power Plant Pipelines (원전감육배관 UT 두께측정 결과의 신뢰도 평가를 위한 다자비교시험)

  • Lee, Seung-Joon;Yi, Won-Geun;Lee, Joon-Hyun;Lee, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1702-1707
    • /
    • 2007
  • The reduction of pipe-thickness induced by flow accelerated corrosion (FAC) is one of the most serious problems on the maintenance of piping system in nuclear power plants (NNP). If the thickness of a pipe component is reduced below the critical level, it cannot sustain pressure and consequently results in leakage or rupture. For this reason, wall thinning by FAC has been inspected in secondary side piping systems in NPPs. In this research Round Robin Test (RRT) was conducted to verify confidence of wall thinning measurement system in NPP. 12 inspectors from 3 companies participated and 23 specimens were used according to standard practice in RRT. The gage R&R analysis was introduced in regard to repeatability and reproducibility that are affected to measurement system errors. Confidence intervals of thickness measurement system were obtained.

  • PDF

Automatic Guidance System for Tractor based upon Position-measurement Systems (위치(位置) 측정장치(測定裝置)를 이용한 트랙터의 자동(自動) 주행장치(走行裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.79-87
    • /
    • 1990
  • An automatic guidance system based upon two position-measurement systems was designed to record where the tractor traveled and to guide the tractor along the predetermined path. An algorithm, using the kinematic behavior of tractor movement, was developed to determine the steering angle to reduce lateral position error. The algorithm was based upon constant travel speed, constant steering rate, and zero slip angles of the tractor wheels. The algorithm was evaluated through use of computer simulation and verified in field experiments. Results showed that the distance interval between position measurements was an important factor in guidance system performance. The position-measurement error of the guidance system must be less than 5 cm to be acceptably precise for field operations. An algorithm based upon a variable steering rate might improve the stability of the guidance system. More accurate measurement of tractor position and yaw angle, and faster error processing are required to improve the field performance of the guidance system.

  • PDF

Profile Error Measurement of a Turbine Blade Using a Contact Type 3D-Scanner (접촉식 3차원 형상스캐너를 이용한 터빈 블레이드의 형상 정밀도 측정)

  • Kang, Byung-Su;Kang, Jae-Gwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.76-81
    • /
    • 2006
  • In this paper, profile error measurement method of a turbine blade using 3D-scanner is developed. The method begins with scanning the upper and lower sides of the blade on which three small balls are attached, and constructs a solid measurement model by registering the two scanned surfaces. Airfoils are derived from the model at each interval by intersecting it with a plane, and arranged with design airfoils. The $2^2$ factorial design search method is engaged in arranging the two airfoils, from which the main blade parameters including the edge radius are computed. The developed measurement technique is applied to practical blade manufacturing and validates its effectiveness.

The Design and Implementation of Mouse Activity Measurement System using Infrared Sensor

  • Kwak, Ho-Young;Huh, Jisoon;Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.81-89
    • /
    • 2016
  • In this paper, we design and implement a mouse movement measurement system using an infrared sensor called MAMS (Mouse Activity Measurement System). Unlike existing systems, MAMS can measure movements between IREDs. MAMS is removable allowing convenient portability and is also low cost. MAMS automatically measures mouse activity during a pre-set time interval. Since the measured data can be easily stored in a computer system, it is much simpler and more efficient than the Ugo 47420 model. Moreover, MAMS can be used in medical and veterinary field to eliminate manual observations.

Field Measurements of Exterior Noise at Apartment Houses (공동주택 외부소음 현장측정방법)

  • Song, Min-Jeong;Jung, Sung-Soo;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.359-362
    • /
    • 2005
  • Road traffic noise level and railway noise level are important factors on apartment inhabitant's comforts. The measurement methods which noted by Ministry of Construction & Transportation(MOCT) and Ministry of Environment(ME) are used for measurement of exterior noise at apartment houses. But these methods are out of date because the height of apartment houses have increased dramatically and owing to the sampling methods of the measurement time interval, rating values are induced differently due to sampling methods. In this study, the sound level of each floor of apartment houses is measured and compared. And rating value due to sampling methods are compared. As a result, the KS outline of 'Field Measurement of Exterior Noise at Apartment Housess' is suggested.

  • PDF