• Title/Summary/Keyword: measurement interval

Search Result 689, Processing Time 0.027 seconds

The Effect of Sahyangsohapwon on Heart Rate Variability of Healthy Subjects (사향소합원(麝香蘇合元)이 정상인의 심박변이도에 미치는 영향)

  • Kim, Chang-Hyun;Hwang, Jae-Woong;Min, In-Kyu;Kim, Mi-Young;Byeon, Hyung-Sik;Na, Byong-Jo;Park, Sung-Wook;Park, Jung-Mi;Ko, Chang-Nam;Bae, Hyung-Sup;Jung, Woo-Sang;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk
    • The Journal of Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.120-127
    • /
    • 2009
  • Objectives: Sahyangsohapwon (SS) is a herbal medication that has been widely used with circulatory and neural diseases. This study was conducted to assess the effect of SS on the autonomic nervous system by using heart rate variability measurement. Methods: The eligible subjects were enrolled from the healthy male group of ages 20 to 35 years. They were divided into two groups, the SS group (n=26) and the control (n=24). We monitored the ECG of subjects from the time period 14:00 to 18:00. In the SS group, subjects were administered with a dose of SS at the time 15:00, whereas the control group had none. For each hour HRV measurement was monitored every 15 minutes for 512 seconds from the time period 14:00 to 18:00. The mean value, which was calculated using the 4 values during each hour (i.e. 14:00, 14:15, 14:30, 14:45), was used as the representative value for each individual hour. For the measurement values, RR-interval and SDNN (standard deviation of the NN intervals) were used as time domain analysis, and HF (high frequency), LF (low frequency), and LF/HF ratio were used as frequency domain analysis. Results: The LF value showed an increase after one hour of SS administration and showed gradual diminution for each and every hour. The repeated measures of ANOVA for the comparison of the LF value between the SS group and the control group showed significant differences. While, RR interval, SDNN, HF, and LF/HF ratio values showed no significant differences between the two groups. Conclusions: We suggest that the SS might be useful for stabilizing autonomic nervous system by inhibiting sympathetic nerve activation in healthy people.

  • PDF

Echocardiographic Follow-up after Arterial Switch Operation for Transposition of the Great Arteries (동맥전환술을 시행한 대혈관전위 환자에서 심초음파를 이용한 술후 추적)

  • 한승세;정태은;이동협;오정훈;이정철
    • Journal of Chest Surgery
    • /
    • v.34 no.10
    • /
    • pp.754-762
    • /
    • 2001
  • Background: To evaluate the efficacy of arterial switch operation for transposition of great arteries, serial echocardiographic studies were performed in 8 patients who underwent the surgery between 1989 and 1998 at Dept. of Thoracic & Cardiovascular Surgery, Yeungnam University Hospital in Daegu City, Korea. Material and Method: Follow-up period ranged from 6 months to 11 years(average of 4.1 years). Body weight ranged from 2.6kg to 4.8kg, with average of 3.6kg. 5 of 8 patients were preoperatively diagnosed as TGA+VSD, and 3 as TGA+IVS. LV function was evaluated by the measurement of LV shortening fraction, LVSTI, and LVEF. RVSTI was also measured. Postoperative function of valve and growth of great vessels were analyzed by the measurement of PSPGV, valvular regurgitation, LA/AO ratio, root dimension of aorta and pulmonary artery, comparing with the age matched controls, respectively. Result: LVEF had an average of 65.0+9.03% which is tended to increase serially. LVAOPG had an average of 15.9mmHg. RVPAPG, 27.5mmHg. From the measurement of aortic root dimension of 6 patients at end-systole, aortic root growth was assumed to increase more than the mean value of normal growth. PA root dimension at end-systole showed a similar growth progress when compared with age matched normal controls. Postoperative pulmonic valve regurgitation was noted in 5 of total 8 patients, in which 1 patient who showed grade 2 and 4 showed below grade 1. AR, in 6 patients and all grade 1 Except 1 patient, all the valvular regurgitations were below grade 1, which was presumed to be clinically insignificant.

  • PDF

A Method to Evaluate the Radar Rainfall Accuracy for Hydrological Application (수문학적 활용을 위한 레이더 강우의 정확도 평가 방법)

  • Bae, Deg-Hyo;Phuong, Tran Ahn;Yoon, Seong-Sim
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1039-1052
    • /
    • 2009
  • Radar measurement with high temporal and spatial resolutions can be a valuable source of data, especially in the areas where rain gauge installment is not practical. However, this kind of data brings with it many errors. The objective of this paper is to propose a method to evaluate statistically the quantitative and qualitative accuracy at different radar ranges, temporal intervals and raingage densities and use a bias adjustment technique to improve the quality of radar rainfall for the purpose of hydrological application. The method is tested with the data of 2 storm events collected at Jindo (S band) and Kwanak (C band) radar stations. The obtained results show that the accuracy of radar rainfall estimation increases when time interval rises. Radar data at the shorter range seems to be more accurate than the further one, especially for C-band radar. Using the Monte Carlo simulation experiment, we find out that the sampling error of the bias between radar and gauge rainfall reduces nonlinearly with increasing raingage density. The accuracy can be improved considerably if the real-time bias adjustment is applied, making adjusted radar rainfall to be adequately good to apply for hydrological application.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

A Study on the Assessment of Pollution Loads at Small Stream in Yeongsan River Watershed (영산강수계 소하천의 오염부하량 평가에 관한 연구)

  • Ha, Don-Woo;Shim, Hongbin;Kim, Haesung;Kim, Yoonsoo;Cho, Sohyun;Song, Chang-Soo;Kang, Taegu;Kim, Yeong-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, the load of the river was calculated by using the actual data of the Yeong-bon C1, Yeong-bon C2, Yeong-bon C3 monitoring points of the Yeong-san river watershed to determine the excess. As a result, the BOD is 75.83 % at the Yeong-bon C1 and the five-year average value is higher than at other points. The Yeong-bon C3 was 72.15 % and Yeong-bon C2 was analyzed as 68.78 %. The five-year average of the T-P was 71.95 % for the Yeong-bon C2 and 69.86 % for the Yeong-bon C3 and 69.16 % for Yeong-bon C1; these levels exceeded the target water quality standards of 50 %. As a result of analyzing the pollutant load, we found that the Yeong-bon C1 has been highly affected by the nonpoint pollution source because the excess rate is high in the upper section of the flow rate. The Yeong-bon C2 showed a high excess rate in the lower part of the flow rate, and it was estimated that the influence of the point pollution source was large. The excess rate of the Yeong-bon C3 is small in the interval deviation, and it was evaluated as being affected by both point and non-point pollution sources. The TMDL monitoring network data were used to estimate the exceed ratio for the target water quality assessment, and the implementation evaluation was made by the flow exceedance probability interval to analyze the monitoring data so that the data could be utilized according to the purpose of the measurement network.

Nondestructive Evaluation of Remanent Life of Turbine Rotor Steel by Measuring Reversible Magnetic Permeability (가역투자율 측정에 의한 터빈로터강의 비파괴적 잔여수명 평가)

  • Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.315-321
    • /
    • 2003
  • The integrity of the turbine rotors can be assessed by measuring the material properties at service temperature. In order to evaluate the remanent life of turbine rotor steel nondestructively, a measurement system of reversible magnetic permeability using an alternating perturbing magnetic field was constructed. We present a new non-destructive method to evaluate the remanent life of 1Cr-1Mo-0.25V steel using the value of reversible magnetic permeability. This method is based on the existence of reversible magnetic permeability in the differential magnetization around the coercive field strength. We measured the first harmonics voltage induced in a coil using a lock-in amplifier tuned to an exciting frequency. The Results of reversible magnetic Permeability and Wickers hardness on the aged samples show that the peak interval of reversible magnetic permeability (PIRMP) and Vickers hardness decreases as aging time increases. A softening curve is obtained from the correlation between Vickers hardness and the PIRMP. This curve can be used as a non-destructive method to evaluate the remanent life of turbine rotor steel.

Normal Glenohumeral and Scapulothoracic Movement at the Coronal Plane (정상인의 관상면에서의 관절와상완운동 및 견갑흉곽운동)

  • Rhee Yong-Girl;Vim Chang-Moo
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.93-99
    • /
    • 1998
  • We measured the glenohumeral and scapulothoracic movements during abduction of the arm in the coronal plane with radiologic analysis in the 30 shoulders of normal male adults who were without pain, limitation of motion, and history of trauma. In the resting position, the glenoid cavity of the scapula faced somewhat superiorly in over 80 percents of the individuals, the mean superior tilting was 5.7 degrees. The mean total scapulothoracic movement was 65.8 degrees and the mean total glenohumeral movement was 106.8 degrees during abduction of arm in the coronal plane. The mean ratio of the glenohumeral movement to the scapulothoracic movement was 1.6 and this GH/ST ratio was decreased toward the extreme abduction. When the arm was abducted, external rotation of the humeral head occurred and this external rotation was increased smoothly during 0 degree through 90 degrees, but steeply above 90 degrees. The acromiohumeral interval was 10.9 mm at the resting positon, and this interval decreased during the arm abduction. The superior migration of the humeral head was 3.1 mm while abducting the arm. Our measurement of the relationships of glenohumeral and scapulothoracic movements at the coronal plane would be useful in the understandings of the biomechanics of shoulder, but further study would be required for the analysis of the three dimensional relationship because of the limitation of our two dimensional analysis.

  • PDF

Evaluation of PPG signals regarding to video attributes of smart-phone camera (스마트폰 카메라의 영상 속성에 따른 맥파 신호 평가)

  • Lee, Haena;Kim, Minhee;Whang, MinCheol;Kim, Dong Keun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.917-924
    • /
    • 2015
  • In this study, we study that the video attributes captured by built-in camera in smart-phone can effect on the quality of PPG signal. The conditions of video attributes were composed of the bitrate, the resolution, the flash. As each condition, we measured a change in the red value of the video image and calculated a PPI(Pulse to Pulse Interval) for extracting the pulse wave signal. 20 subjects participated in the experiment and this experiment was carried out 18 tasks. The PPG signal was measured simultaneously for two minutes with the PPG sensor in the middle finger and Smart-phone in the forefinger of the right hand. By proceeding the correlation analysis, we obtained the highest correlation condition(83%, p=0.01), which the resolution was $640{\times}480$, bitrate was 5000kbps, flash was on. As a result, this study will be a useful guide for quality of signals in the pulse signal measurement system using built-in camera in smart-phone.

A Study on the Effect of Large Coherent Structures to the Skin Friction by POD Analysis (적합직교분해(POD)기법을 사용한 난류 응집구조 거동에 관한 연구)

  • Shin, Seong-Yun;Jung, Kwang-Hyo;Kang, Yong-Duck;Suh, Sung-Bu;Kim, Jin;An, Nam-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.5
    • /
    • pp.406-414
    • /
    • 2017
  • An experimental study in a recirculating water channel was carried out to investigate the effect of large coherent structures to the skin friction on a flat plate. Particle Image Velocimetry (PIV) technique was used to quantify characteristic features of coherent structures growing to the boundary layer. In the PIV measurement, it is difficult to calculate the friction velocity near the wall region due to laser deflection and uncertainty so that Clauser fitting method at the logarithmic region was adopted to compute the friction velocity and compared with the one directly measured by the dynamometer. With changing the free-stream velocity from 0.5 m/s to 1.0 m/s, the activity of coherent structures in the logarithmic region was increased over three times in terms of Reynolds stress. The flow field was separated by Variable Interval Time Averaging (VITA) technique into the weak and the strong structure case depending on the existence large coherent structures in order to validate its effectiveness. The stream-wise velocity fluctuation was scanned through at the boundary thickness whether it had a large deviation from background flow. With coherent structures connected from near-wall to the boundary layer, mean wall shear stress was higher than that of weak structure case. Proper Orthogonal Decomposition (POD) analysis was also applied to compare the energy budget between them at each free-stream velocity.

Confidence Bounds following Adaptive Group Sequential Tests with Repeated Measures in Clinical Trials (반복측정자료를 가지는 적응적 집단축차검정에서의 신뢰구간 추정)

  • Joa, Sook Jung;Lee, Jae Won
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.4
    • /
    • pp.581-594
    • /
    • 2013
  • A group sequential design can end a clinical trial early if a confirmed efficacy or a futility of study medication is found during clinical trials. Adaptation can adjust the design of clinical trials based on accumulated data. The key to this methodology is considered to control the overall type 1 error rate while maintaining the integrity of clinical trials. The estimation would be more complex and the sample size calculation will be more difficult if the clinical trials have repeated measurement data. Lee et al. (2002) suggested a repeated observation case by using the independent increments properties of the interim test statistics and investigated the properties of the proposed confidence interval based on the stage-wise ordering. This study extend Lee et al. (2002) to adaptive group sequential design. We suggest test statistics for the adaptation as redesigning the second stage of clinical trials and induce the stage-wise confidence interval of parameter of interests. The simulation will help to confirm the suggested method.