• Title/Summary/Keyword: measurement instrument

Search Result 983, Processing Time 0.03 seconds

A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents (대체 세정제의 선정을 위한 세정성 평가방법 연구)

  • Shin, Jin-Ho;Lee, Jae-Hoon;Bae, Jae-Heum;Lee, Min-Jae;Hwang, In-Gook
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • In this study various cleaning evaluation methods were tested and comparatively evaluated to help cleaning industry. In order to select alternative cleaning agents objectively and systematically, various cleaning evaluation methods such as gravimetric, optically simulated electron emission (OSEE), contact angle, and analytical instrument methods were employed for cleaning contaminants such as flux, solder and grease. The analytical instruments used in this work were Fourier transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV-VIS) and high performance liquid chromatography (HPLC). The gravimetric method was able to measure cleaning efficiencies easily and simply, but it was not easy to analyze them precisely because of its limitation in the gravimetric measurement. However, the OSEE technique was able to measure quickly and precisely the clean ability of cleaning agents in comparison with the gravimetric method. The contact angle method was found to be necessary for taking special precaution in its application to the cleaning evaluation due to possible formation of tiny organic film on the substrate surface which might be generated from contaminants and cleaning agents. In case of precision analysis that cannot be done by gravimetric method, fine analytical instruments such as UV-VIS, FTIR and HPLC could be used in analyzing trace amount of flux, solder and grease quantitatively, which were extracted from the surface by special solvents.

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

Developing Measurement Items for the Service Quality of Clinical Trials based on the Brady & Cronin Model (Brady & Cronin의 모델에 기반한 임상시험 서비스 질 측정 문항 개발)

  • Go-Eun Lee;Sanghee Kim;Sue Kim;Sang Hui Chu;Jeong-Ho Seok;So Yoon Kim
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.17-31
    • /
    • 2024
  • Purpose: This study aims to develop preliminary items for measuring the perceived service quality of clinical trials among participants and to verify content validity. Methods: This study was designed as a methodological study. A conceptual framework was established based on Brady and Cronin's hierarchical model, and preliminary items were prepared through translation-back-translation, a review of existing instruments, and in-depth interviews with clinical trial participants and clinical research coordinators. The final items were completed through content validity testing by experts and a review of items by clinical trial participants for the prepared preliminary items. Results: Through this study, a set of 58 items across four domains (quality of interaction with researchers, the physical environment, performance procedures, and performance results) and 9 components (information·education·communication, trust, respect for participant preferences, securing facilities and space, accessibility, comfortability, informed consent, coordination of care, subjective understanding of clinical trials) on the service quality of clinical trials were completed. The scale content validity index of all preliminary items was 0.96, meeting the recommended standards. The individual-item content validity index also meets the recommended criteria for most items, excluding four items. Conclusion: This study holds significance in developing items to measure the quality of clinical trial execution from the perspective of participants. By verifying the reliability and validity of these items through subsequent research, it is expected that they can be utilized as a valuable instrument to devise strategies for improving the quality of clinical trials.

  • PDF

The Clinical Study on Correlation between Knee Osteoarthritis and Obesity (퇴행성 슬관절염과 비만과의 상관성에 관한 임상 연구)

  • Kang, Jung-Won;Ryu, Seong-Ryong;Seo, Byung-Kwan;Cho, Mi-Ran;Cho, Ryo-Won;Woo, Hyun-Su;Lee, Sang-Hoon;Choi, Do-Young;Kim, Keon-Sik;Lee, Doo-Ik;Lee, Yun-Ho;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.17-26
    • /
    • 2005
  • Objectives : The purpose of this study is to investigate the correlation between assessment measurements of knee osteoarthritis and obesity. Methods : Data on assessment measurements of knee osteoarthritis and obesity were obtained from 63 patients suffering from knee osteoarthritis from February to April, 2005. The assessment measurements consisted of BMI (body mass index), WHR (waist-hip ratio), two disease-specific questionnaires (Western Ontario and McMaster Universities (WOMAC) index and Lequesne's Functional Severity Index (LFI)), one generic instrument (Korean Health Assessment Questionnaire (KHAQ)), and VAS (Visual Analogue Scale). Statistical correlations among assessment measurements were evaluated by examining the Pearson's correlation coefficients. Results : 1. The sexual ratio in this study was 1: 5.3 (male: female= 10: 53). The average age of all patients was $59.1{\pm}6.6$ (male: $58.3{\pm}7.1$, female: $59.2{\pm}6.5$), and the group of 60-69 (34 patients, 54%) was biggest in the age distribution. 2. The average BMI of all patients was $25.4{\pm}3.1\;kg/m^2$ (male: female= $23.6{\pm}2.6\;kg/m^2:\;25.8{\pm}3.0\;kg/m^2$), and the group of $20-25\;kg/m^2$ was biggest in the BMI distribution. According to clinical definition of obesity by WHO (1997), 52.4% of all patients was within normal weight, 42.9% was overweight, and 4.8% was obese. 3. The average WHR of all patients was $0.91{\pm}0.06$ (male: female= $0.90{\pm}0.05:\;0.92{\pm}0.06$). According to definition of abdominal obesity, 73.0% of all patients (46 patients were all female) was in the state of abdominal obesity. 4. There were no significant correlations in statistics among assessment measurements except between BMI and WHR. Conclusion : Though there is significant correlation between knee osteoarthritis and obesity according to many clinical and experimental researches, there is no assessment measurement reflecting knee osteoarthritis and obesity simultaneously. For this, further studies on correlation between knee osteoarthritis and obesity and development of assessment measurement or questionnaire on this are needed.

  • PDF

Single Laboratory Validation and Uncertainty Estimation of a HPLC Analysis Method for Deoxynivalenol in Noodles (면류에서 HPLC를 이용한 데옥시니발레놀 분석법의 검증과 불확도 산정)

  • Ee, Ok-Hyun;Chang, Hyun-Joo;Kang, Young-Woon;Kim, Mee-Hye;Chun, Hyang-Sook
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.142-149
    • /
    • 2011
  • An isocratic high performance liquid chromatography (HPLC) method for routine analysis of deoxynivalenol in noodles was validated and estimated the measurement uncertainty. Noodles (dried noodle and ramyeon) were analyzed by HPLC-ultraviolet detection using immunoaffinity column for clean-up. The limits of detection (LOD) and quantification (LOQ) were 7.5 ${\mu}g$/kg and 18.8 ${\mu}g$/kg, respectively. The calibration curve showed a good linearity, with correlation coefficients $r^2$ of 0.9999 in the concentration range from 20 to 500 ${\mu}g$/kg. Recoveries and Repeatabilities expressed as coefficients of variation (CV) spiked with 200 and 500 ${\mu}g$/kg were $82{\pm}2.7%$ and $87{\pm}1.3%$% in dried noodle, and $97{\pm}1.6%$ and $91{\pm}12.0%$ in ramyeon, respectively. The uncertainty sources in measurement process were identified as sample weight, final volume, and sample concentration in extraction volume as well as components such as standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. Deoxynivalenol concentration and expanded uncertainty in two matrixes spiked with 200 ${\mu}g$/kg and 500 ${\mu}g$/kg were estimated to be $163.8{\pm}52.1$ and $435.2{\pm}91.6\;{\mu}g$/kg for dried noodle, and $194.3{\pm}33.0$ and $453.2{\pm}91.1\;{\mu}g$/kg for ramyeon using a coverage factor of two which gives a level of statistical confidence with approximately 95%. The most influential component among uncertainty sources was the recovery of matrix, followed by calibration curve.

A Study on the Moderating Effect of Perceived Voluntariness in the Organizational Information System Usage and Performance (정보시스템 사용과 성과에 있어서 자발성의 조절효과에 관한 연구)

  • Lee, Seung-Chang;Lee, Ho-Geun;Jung, Chang-Wook;Chung, Nam-Ho;Suh, Eung-Kyo
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.195-221
    • /
    • 2009
  • According to an industry report, a large number of organizations have invested in Organizational Information System(OIS) in the past few years. Several research results indicate that successful investments in OIS lead to productivity enhancement, while failed ones result in undesirable consequences such as financial losses and dissatisfaction among employees. In spite of huge investments, however, many organizations have failed in achieving the hoped-for returns from OIS. Thus, understanding user acceptance, adoption, and usage of new IS(Information Systems) is an important issue for IS practitioners. Indeed, study of the user acceptance of new information system has been one of the most important research topics in the contemporary IS literature. Several theoretical models are tested to examine 'user acceptance' and 'usage behavior' in IS context. While many research models incorporate 'ease of use' or 'usefulness' as important factors in explaining user acceptance, Technology Acceptance Model(TAM) has been one of the most widely applied models in user acceptance and usage behavior. Even in recent IS studies that employ theories of innovation diffusion in the area of IS implementation, a major focus has been on the user's perception of information technologies. In this research, we study 'voluntariness' as an important factor in IS acceptance by users. Voluntariness is defined as "the degree to which the use of the innovation is perceived as being voluntary, or of free will" When examining the diffusion of accepting OIS, a thoughtful consideration should be given to 'perceived voluntariness.' Current article has following research questions: 1) What models are appropriate to explain the success of OIS? and 2) How does the 'voluntariness' affect the success of OIS? In order to answer these questions, a research model is proposed to describe the detailed nature of association among three independent variables (IT usage level, task interdependency, and organizational support), a mediating variable (IS usage), a dependent variable (perceived performance), and a moderating variable(perceived voluntariness). The central claim of this article is that organizations hardly realize expected returns from OIS investments unless perceived voluntariness is effectively managed after operating OIS. As an example of OIS in this study we have selected the Intranet of Republic of Korea Air Force (ROKAF). ROKAF has implemented the Intranet in an attempt to improve communication and coordination within the organization. To test our research model and hypotheses, survey questionnaires were first sent out to 400 Intranet users. With the assistance of ROKAF, Intranet users were initially identified among its members, and subjects were randomly drawn from the pool. 377 survey responses were finally returned. The unit of measurement and analysis in this research is a personal level. Path analysis based on structural equation modeling was used to test research hypotheses. Construct validity represents accordance between the theoretical base concept of constructs and its measurement items. Tests for the reliability and discriminant validity are accepted, thus verifying our survey instrument. In this research, we have proposed a conceptual framework to highlight the importance of perceived voluntariness after organization deploys OIS. The results of our analysis present several key finding. First, all three independent variables (IT usage level, task interdependency, and organizational support) have significant effects on IS usage, which will eventually improve performance. Thus, IS usage plays a mediating role between antecedent variables (IT usage level. task interdependency, and organizational support) and performance improvement. Second, the effect of the task dependency was the highest for IS usage among the three antecedent variables. This is highly plausible since one of the Intranet's major capabilities is to facilitate communication among members within an organization. Accordingly, we conclude that the higher the task dependency, the higher Intranet usage. The effect of user's IT usage level was the second, while the effect of the organizational support was the third. Finally, the perceived voluntariness plays a pivotal role in enhancing perceived performance in personal level after launching the Intranet. Relationships among investigated variables were significantly different between groups with a high level and a low level of voluntariness. The impact of the Intranet usage on the performance was greater in the higher level voluntariness group than in the lower one. For the lower level voluntariness group, the user's IT usage had the highest effect on the Intranet usage among the three antecedent variables. In short, our study suggests that the higher the perceived voluntariness is the more IS usage will be. Perceived voluntariness was found to have a moderating effect on the relationships among user IT usage level, task interdependency, IS usage, and perceived performance, supporting all the hypotheses on the moderating effect. Most of all, user IT usage level has the strongest influence on IS usage, indicating that users with superior IT usage are more likely to enjoy a high level of perceived performance.

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Review of applicability of Turbidity-SS relationship in hyperspectral imaging-based turbid water monitoring (초분광영상 기반 탁수 모니터링에서의 탁도-SS 관계식 적용성 검토)

  • Kim, Jongmin;Kim, Gwang Soo;Kwon, Siyoon;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.919-928
    • /
    • 2023
  • Rainfall characteristics in Korea are concentrated during the summer flood season. In particular, when a large amount of turbid water flows into the dam due to the increasing trend of concentrated rainfall due to abnormal rainfall and abnormal weather conditions, prolonged turbid water phenomenon occurs due to the overturning phenomenon. Much research is being conducted on turbid water prediction to solve these problems. To predict turbid water, turbid water data from the upstream inflow is required, but spatial and temporal data resolution is currently insufficient. To improve temporal resolution, the development of the Turbidity-SS conversion equation is necessary, and to improve spatial resolution, multi-item water quality measurement instrument (YSI), Laser In-Situ Scattering and Transmissometry (LISST), and hyperspectral sensors are needed. Sensor-based measurement can improve the spatial resolution of turbid water by measuring line and surface unit data. In addition, in the case of LISST-200X, it is possible to collect data on particle size, etc., so it can be used in the Turbidity-SS conversion equation for fraction (Clay: Silt: Sand). In addition, among recent remote sensing methods, the spatial distribution of turbid water can be presented when using UAVs with higher spatial and temporal resolutions than other payloads and hyperspectral sensors with high spectral and radiometric resolutions. Therefore, in this study, the Turbidity-SS conversion equation was calculated according to the fraction through laboratory analysis using LISST-200X and YSI-EXO, and sensor-based field measurements including UAV (Matrice 600) and hyperspectral sensor (microHSI 410 SHARK) were used. Through this, the spatial distribution of turbidity and suspended sediment concentration, and the turbidity calculated using the Turbidity-SS conversion equation based on the measured suspended sediment concentration, was presented. Through this, we attempted to review the applicability of the Turbidity-SS conversion equation and understand the current status of turbid water occurrence.

Development of Extracting Solution for Soil Chemical Analysis Suitable to Integrated Ion-selective Micro-electrodes (집적형 이온선택성 미세전극 센서에 적합한 토양화학 분석용 침출액 종 개발)

  • Shin, Kook-Sik;Lim, Woo-Jin;Lee, Sang Eun;Lee, Jae Seon;Cha, Geun Sig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.513-521
    • /
    • 2009
  • The primary goal of this research was to develop an optimized analytical procedure for soil analysis based on ion-selective microelectrodes for agricultural purposes, which can perform on-site measurement of various ions in soil easily and rapidly. For the simple and rapid on-site diagnosis, an analysis of soil chemicals was performed employing a multicomponent-in-situ-extractant and an evaluation of ionselective microelectrodes were conducted through the regressive correlation method with a standard analytical approach widely employed in this area. Examination of sensor responses between various soil nutrient extractants revealed that 0.01M HCl and 1M LiCl provided the most ideal Nernstian response. However, 1M LiCl deteriorated the selective response for analytes due to high concentration (1M) of lithium cation. Thus, employing either 0.1M HCl as an extractant followed by 10 times dilution, or 0.01M HCl as an extractant without further dilution was chosen as the optimal extractant composition. A study of regressive correlation between results from ion-selective microelectrodes and those from the standard analytical procedure showed that analyses of $K^+$, $Na^+$, $Ca^{2+}$, and $NO_3{^-}$ showed the excellent consistency between two methods. However, the response for $NH_4{^+}$ suffered the severe interference from $K^+$. In addition, the selectivity for $Mg^{2+}$ over $Ca^{2+}$ was not sufficient enough since available ionophores developed so far do not provide such a high selectivity for $Mg^{2+}$. Therefore, as an agricultural on-site diagnostic instrument, the device in development requires further research on $NH_4{^+}$ analysis in the soil sample, development of $Mg^{2+}$-selective ionophore, and more detailed study focused on potassium, one of the most important plant nutrients.

Improvement of analytical methods for arsenic in soil using ICP-AES (ICP-AES를 이용한 토양 시료 중 비소 분석 방법 개선)

  • Lee, Hong-gil;Kim, Ji In;Kim, Rog-young;Ko, Hyungwook;Kim, Tae Seung;Yoon, Jeong Ki
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.409-416
    • /
    • 2015
  • ICP-AES has been used in many laboratories due to the advantages of wide calibration range and multi-element analysis, but it may give erroneous results and suffer from spectral interference due to the large number of emission lines associated with each element. In this study, certified reference materials (CRMs) and field samples were analyzed by ICP-AES and HG-AAS according to the official Korean testing method for soil pollution to investigate analytical problems. The applicability of HG-ICP-AES was also tested as an alternative method. HG-AAS showed good accuracies (90.8~106.3%) in all CRMs, while ICP-AES deviated from the desired range in CRMs with low arsenic and high Fe/Al. The accuracy in CRM030 was estimated as below 39% at the wavelength of 193.696 nm by ICP-AES. Significant partial overlaps and sloping background interferences were observed near to 193.696 nm with the presence of 50 mg/L Fe and Al. Most CRMs were quantified with few or no interferences of Fe and Al at 188.980 nm. ICP-AES properly assessed low and high level arsenic for field samples, at 188.980 nm and 193.696 nm, respectively. The importance of the choice of measurement wavelengths corresponding to relative arsenic level should be noted. Because interferences were affected by the sample matrix, operation conditions and instrument figures, the analysts were required to consider spectral interferences and compare the analytical performance of the recommended wavelengths. HG-ICP-AES was evaluated as a suitable alternative method for ICP-AES due to improvement of the detection limit, wide calibration ranges, and reduced spectral interferences by HG.