• Title/Summary/Keyword: measurement instrument

Search Result 986, Processing Time 0.023 seconds

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Evaluating pollution origins of runoff in urban area by stormwater (강우시 도시지역 강우 유출수 오염부하 기원평가)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.930-934
    • /
    • 2006
  • In this study, we conducted water-quality analysis of wastewater and in-situ flow measurement using automatic flow rate measuring instrument to identify characteristics of wastewater in urban areas, and collected samples in gutter fur storm water drain, rainfall bucket, and aqueduct of pipe from roof, and outfalls of basins to examine the contribution by pollution origins such as base wastewater, atmospheric washing, runoff by roof surface, runoff by road surface, erosion of sewer sediment. In the result, the concentration of pollutants reached peak in the beginning of rainfall due to first flush, was 3 to 10 times higher than average concentration of dry period, and was lower than that of dry period due to dilution of storm water. In the analysis of the contribution by pollution origins, the ratio of load by sewer sediment resuspension to the total pollution load was 54.6% fer COD, and 73.3% fur SS. Accordingly, we can reduce the total pollutant load by periodical dredging and washing of sewer sediment, and control the loadings by overflow of combined sewer overflows.

  • PDF

The Factorial Structure and Psychometric Properties of the Persian Effort-Reward Imbalance Questionnaire

  • Babamiri, Mohammad;Siegrist, Johannes;Zemestani, Mehdi
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.334-338
    • /
    • 2018
  • Background: With global changes in the current state of work and employment, the role of health-adverse psychosocial work environments has received increasing attention in developed as well as in rapidly developing countries. Thus, there is a need to apply valid measurement tools for monitoring and preventive purposes. This study aims to examine the factorial structure and psychometric properties of the Persian version of the effort-reward imbalance (ERI) questionnaire, assessing one of the internationally leading concepts of stressful work. Methods: This descriptive cross-sectional study of a random sample of 202 white collar employees in an industrial company in Iran analyzes the ERI scales by exploratory and confirmatory factor analysis. Moreover, aspects of construct and criterion validity are tested. To this end, correlations of ERI scales with subscales of organizational injustice, a complementary work stress model, and also the correlations of ERI scales with a questionnaire assessing psychosomatic symptoms are performed. Results: Internal consistency of the three ERI scales was satisfactoryy (Cronbach ${\alpha}$ effort: 0.76, reward: 0.79, overcommitment: 0.75). Fit indices of confirmatory factor analsis pointed to an adequate representation of the theoretical construct (e.g., adjusted goodness of fit index (AGFI): 0.73, goodness of fit index (GFI): 0.78). Negative correlations with subscales of organizational injustice supported the notion of construct validity of the ERI scales, and positive correlations of ERI scales with psychosomatic symptoms indicated preliminary criterion validity. Conclusion: The Persian version of the ERI questionnaire has acceptable psychometric properties and can be used as a valid instrument in research on this topic.

Measurement of electron temperature and density using Stark broadening of the coaxial focused plasma for extreme ultraviolet (EUV) lithography

  • Lee, Sung-Hee;Hong, Young-June;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.475-475
    • /
    • 2010
  • We have generated Ar plasma in dense plasma focus device with coaxial electrodes for extreme ultraviolet (EUV) lithography and investigated an emitted visible light for electro-optical plasma diagnostics. We have applied an input voltage 4.5 kV to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas of pressure 8 mTorr. The inner surface of the cylindrical cathode has been attatched by an acetal insulator. Also, the anode made of tin metal. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium (LTE) conditions, the electron temperature and density of the coaxial plasma focus could be obtained by Stark broadening of optical emission spectroscopy (OES). The Lorentzian profile for emission lines of Ar I of 426.629 nm and Ar II of 487.99 nm were measured with a visible monochromator. And the electron density has been estimated by FWHM (Full Width Half Maximum) of its profile. To find the exact value of FWHM, we observed the instrument line broadening of the monochromator with a Hg-Ar reference lamp. The electron temperature has been calculated using the two relative electron density ratios of the Stark profiles. In case of electron density, it has been observed by the Stark broadening method. This experiment result shows the temporal behavior of the electron temperature and density characteristics for the focused plasma. The EUV emission signal whose wavelength is about 6 ~ 16 nm has been detected by using a photo-detector (AXUV-100 Zr/C, IRD). The result compared the electron temperature and density with the temporal EUV signal. The electron density and temperature were observed to be $10^{16}\;cm^{-3}$ and 20 ~ 30 eV, respectively.

  • PDF

Estimation of Scour Depth at Bridnges and Comparative Analysis between Estimated and Measured Scour Depths (교량에서의 세굴깊이 산정 및 산정치와 실측치의 비교분석)

  • Yun, Yong-Nam;Lee, Jae-Su;Ho, Jeong-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.5
    • /
    • pp.477-485
    • /
    • 1997
  • Recent internal and external bridge failures due to pier and abutment scour have emphasized the need for better methods of scour depth estimation. This paper compares the hydraulic analysis of the Namhan River Bridge over the Namhan River using one-dimensional models. WSPRO & HEC-2, and the two-dimensional model. TABS-MD based on the procedures presented in HEC-18 published by the U.S. FEdral Highway Administration. A comparison of estimated scour depth for this research based on the results from both one-dimensional and two-dimensional model is presented. At the same time, field measurement has been performed before and after flood using sounding instrument. Fathometer (DE-719C). A comparison between estimated and measured scour depth at bridge is also presented. Result shows that there is all the difference between estimated and measured scour depth due to dissimilarity between laboratory and field conditions. Also, it is difficult to measure the maximum scour depth accurately due to refilling. Therefore development of scour measuring equipment which can be used during peak flood, and derivation of empirical model appropriate for internal river system seems urgent.

  • PDF

Properties of Pulse Waveforms by Posture Changes : Standing, Sitting, Supine Posture (측정 자세의 변화에 따른 맥의 변화 특성 : 선 자세, 앉은 자세, 누운 자세)

  • Kown, Sun-Min;Kang, Hee-Jung;Lee, Sang-Hun;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.4
    • /
    • pp.13-22
    • /
    • 2009
  • Objectives : Informations on pulse diagnosis in literature are based on diagnosing pulse waveforms on supine posture. However, today's pulse waveforms are measured on various postures for the convenience of patients or doctors. For objective measurement, the effect of posture on the pulse waveforms should be considered. The objective of this study was to find posture-related changes in the radial pulse waveforms. Methods : We used an instrument, DMP-3000(DAEYOMEDI Co., Ansan, Korea), measuring radial pulse waveforms noninvasively by tonometric method. 25 male subjects participated in the trial. Before measuring radial pulse waveforms subjects had rest for 5 min. The pulse waveforms were measured on the left wrist. Each subject underwent this course on the supine, sitting, and standing posture. We analyzed pulse waveforms with Height-parameters, Time-parameters, Energy, and Elastic rate. Results : Height-parameters(h1~h5) on the supine posture were bigger than those on the sitting and standing posture. In case of Time-parameters, the parameters making up systolic time decrease in order of on standing, sitting, and supine position. However, systolic time and diastolic time didn't have any changes. Energy of pulse was the biggest on supine posture and Elastic rate on standing posture. Conclusions : In this study we found that posture changes affect radial pulse waveforms. For quantification of the changes, more trials should be done. After analyzing much data we might apply parameters of pulse waveforms changed by posture. Also, we might diagnose special disease with properties of pulse waveforms by posture.

  • PDF

Development and verification of an affective inventory in Mathematical Learning (수학 학습에 대한 정의적 성취 검사 도구 개발 및 검증)

  • Lee, Chong-Hee;Kim, Sun-Hee;Kim, Soo-Jin;Kim, Ki-Yeon;Kim, Bu-Mi;Yun, Soo-Cheol;Kim, Yun-Min
    • The Mathematical Education
    • /
    • v.50 no.2
    • /
    • pp.247-261
    • /
    • 2011
  • In this study, the researchers developed an inventory which can measure the affective achievement in mathematical learning especially targeted to Korean students. By using EFA and CFA, the six affective factors of mathematical learning such as learning directivity, self control, anxiety, interest, cognizing value and confidence are distinguished. Also, the content validity of this inventory was examined by the experts groups, composed of mathematics education professors, high school mathematics teachers, and measurement experts. The reliability of the instrument was high enough to trust the results. Through a large scaled sampling, the reliability and validity of this inventory were verified. In addition, this inventory was developed not by a partial aspects of a certain theory but based on the recent theories. Due to these reasons, the results of this study can be respected that it plays a leading part in understanding the affective achievement of Korean students.

Recent Development of Rapid and Automation Technology for Food Microbiological Examination

  • Hiroshi Kurata
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 1996.06a
    • /
    • pp.33-33
    • /
    • 1996
  • Interests in the field of rapid methods and automation in microbiology have been growing steadily on an international scale in recent years. International meetings concerned this problem have been held in elsewhere in the world countries since the past twenty years. But, unfortunately in the field of microbial examination in food hygiene, this problem have not yet been developed so much as in the field of clinical microbiology. Today, I would like to introduce you here present aspects of rapid and automation technologies, those which are manly carrying in milk and meats industries. My illustration will be given recent improved technologies using automatic apparatus and instruments along with process of microbial count procedure. Recent direct microbiological counting system (ChemeScan \ulcorner) as real time ultrasensitive analysis created by Cheminex Ltd., France is now most evolutional instrument to provide direct microbial counts, down to one cell, within 30 minutes. The results from these evaluations how a good correlation between the ChemScan system and the standard plate count method. This system will be successful application for not only in the field of pharmacology but also food microbiology. In addition, current identification of microbes by sophisticated instruments suitable for food microbiology, one of which Biology is manual system (BIOLOG\ulcorner), provides reference-level capability at a modes price. For the manual system, the color reactions in the microplate are read by eye and manually keyed into personal computer. Species identification appears on the computer screen within seconds, along with biotype patterns, a list of closely related species, and other useful statistics. In present this is useful application for microbial ecology and epidemiological survey. RiboPrinter system newly produced by DuPont is now focusing among microbiologists in the world, and is one of the biggest microbial characterization system using a DNA-based approach. The technology analyzer is bacterial culture for its genetic fingerprint or riboprint pattern. Finally Bio-cellTracer system for automatic measurement of fungal growth and Fukitori-Maseter, a Surface Hygiene Monitoring Kit by using swabe procedure in food processing environment are briefly illustrated in this presentation.

Evaluation of Field Application for the mix properties of the thixotropic grout (가소성그라우트의 배합특성 및 현장 적용성 평가)

  • Kim, Hak-Moon;Jang, Kyung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4223-4238
    • /
    • 2011
  • The advantages of grouting are the simple instrument, the simple procedure of practice and the simple verification of grouting result. but the more grouting practice there is, the more damages of environment from grouting practice and grouting materials there are. so, the grouting materials and methods with the character of environment friendly are introduced in construction field, recently. This paper is to study of the physical characteristics that has thixotropic character and that consists of inorganic and polycarboxylate co-polymer. In study, various testing methods are performed such as a viscosity, a thixotropy, a compressive strength, a heavy metal detection and pH measurement in lab test and a low pressure injection test and a high pressure injection test in field with different soil type. As a result, a optimum mix ratio is proposed by analyzing the result of lab test. the field applicability is verified by checking a injection pressure, a grout volume and a hardened body of grout by excavating the practice site.

Factors Affecting Profitability of General Hospitals Focused on Operating Margin (병원의 수익성 관련 요인 분석 - 의료수익의료이익율을 중심으로 -)

  • Park, Byung-Sang;Lee, Yong-Kyoon;Kim, Yoon-Shin
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.196-206
    • /
    • 2009
  • The profitability of a hospital refers to business administration results achieved through its medical care and other management activities during applicable fiscal year. This study focused on operating margin as a measurement index of hospital profitability, which is a genuine medical return obtained by subtracting medical expenses from medical profits achieved during business administration of hospital. Based on the index, this study could deduce certain factors on hospital profitability in terms of various indices affecting profitability. And based on those factors, this study sought to provide more useful reference materials which allow us to devise possible ways to improve hospital profitability. As a result, it was found that public hospitals attained lower profitability than private ones. To analyze profitability depending on each index, this study divided hospitals broadly into deficit group and surplus group. As a result, it was found that there were significant differences in hospital profitability between two groups depending upon relevant indices such as labor cost ratio, maintenance expense ratio, number of operations per medical specialist and medical instrument turnover. According to analysis on potential effects of relevant indices upon profitability, it was found that each index had its explanatory power ranging from 25% to 74.5% depending on given model.