• 제목/요약/키워드: measurement instrument

검색결과 976건 처리시간 0.028초

기계시각을 이용한 분무입자크기 측정 (Machine Vision Instrument to Measure Spray Droplet Sizes)

  • 전홍영;티안레이
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.443-449
    • /
    • 2010
  • A machine vision-based instrument to measure a droplet size spectrum of a spray nozzle was developed and tested to evaluate its accuracy on measuring spray droplet sizes and classifying nozzle sizes. The instrument consisted of a machine vision, light emitting diode (LED) illumination and a desktop computer. The illumination and machine vision were controlled by the computer through a C++ program. The program controlled the machine vision to capture droplet images under controlled illumination, and processed the droplet images to characterize the droplet size distribution of a spray nozzle. An image processing algorithm was developed to improve the accuracy of the system by eliminating random noise and out-of-focus droplets in droplet images while measuring droplet sizes. The instrument measured sizes of the three different balls (254.0, 497.8 and $793.8\;{\mu}m$) and the measurement ranges were $241.2-273.6\;{\mu}m$, $492.9-529.6\;{\mu}m$ and $800.8-824.1\;{\mu}m$ for 254.0-, 497.84- and $793.75-\;{\mu}m$ balls, respectively. Error of the measured droplet mean was less than 3.0 %. Droplet statistics, $D_{V0.1}$, $D_{V0.5}$ and $D_{V0.9}$, of a reference nozzle set were measured, and droplet size spectra of five spray nozzles covering from very fine to extremely coarse were measured to classify spray nozzle sizes. Ninety percent of the classification results of the instrument agreed with manufacturer's classification. A comparison study was carried out between developed and commercial instruments, and measurement results of the developed instrument were within 20 % of commercial instrument results.

Compact and precision range finder using self-mixing semiconductor laser

  • Shinohara, Shigenobu;Andou, Minoru;Yoshida, Hirofumi;Ikeda, Hiroaki;Miyata, Masafumi;Yoshida, Jun-Ichi;Nishide, Ken-Ichi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.972-978
    • /
    • 1989
  • Proposed is improved compact self-mixing type semiconductor-laser range finder, which measures mode-hop time interval (MHI). Measurement error caused by the fluctuation of MHI is greatly reduced by averaging many contiguous MHI's. The main cause of measurement error 1.5% at ranges from 0.1m to 0.8m is attributed to the optical phase change of a returned light from a focusing lens. Accuracy improvement by stabilization of the returned light is suggested.

  • PDF

대구경 렌즈의 형상 측정을 위한 Fizeau 간섭계 시스템 개발 (Development of a Fizeau Interferometer System for Measuring the Profile of Large Optical Lens)

  • 배광환;이응석;이기암;김옥현
    • 대한기계학회논문집A
    • /
    • 제30권12호
    • /
    • pp.1649-1657
    • /
    • 2006
  • Fizeau interferometer is well known optical instrument for measuring the lens profile accurately. The object of this study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for astronomical purpose. Measuring of large optical lens, the object could not be moved as small one but the measuring instrument must be moved for the alignment, because of the geometric conditions and the accuracy of the stage. Therefore, a five axis stage is designed to align the Interferometer instead of the measuring object. This instrument will be used for an on machine measuring system in polishing machine for large optical lens.

안전한 토석류 관리를 위한 계측기 선정에 관한 연구 (Study of Determination in Measurement System for Safely Managing Debris-Flow)

  • 민대홍;윤형구
    • 한국안전학회지
    • /
    • 제32권3호
    • /
    • pp.41-47
    • /
    • 2017
  • Recent studies have shown that there are various systems which can be used to monitor hazardous area in a debris flow location, but lack of methodological research on the exact location where each instrument should be installed has hindered the success of this systems. The objective of this study is to suggest the measurement system for monitoring debris-flow and propose the effective method to determine location of measurement system. Previously studied, from 1991 to 2015, were referred and the applied ratio of every instrument was investigated. The measurement information was divided into 8 categories including rainfall, debris-flow velocity, displacement, fluid pore pressure, ground vibration, image processing, impact force and peak flow depth. The result of this study revealed that the most applied instruments to be rain gauge and geophone for measuring average rainfall and ground vibration respectively. The Analytic Hierarchical Process (AHP) method was selected to determine installation location of instrument and the weighting factors were estimated through fine content, soil thickness, porosity, shear strength, elastic modulus, hydraulic conductivity and saturation. The soil thickness shows highest weights and the fine content relatively demonstrates lowest weights. The score of each position can be calculated through the weighting factors and the lowest score position can be judged as the weak point. The weak point denotes the easily affecting area and thus, the point is suitable for installing the measurement system. This study suggests a better method for safely managing the debris-flow through a precise location for installing measurement system.

NEAR INFRARED SPECTROSCOPY, A POWERFUL TECHNIQUE IN HUMAN SKIN STUDY : PART I METHOD RELIABILITY AND INFLUENTIAL PARAMETERS

  • Snieder, Marchel;Wiedemann, Sophie;Hansen, Wei G.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3101-3101
    • /
    • 2001
  • Near Infrared spectroscopy (NIR) used on human skin measurement was explored in the past decade. Many publications in different journals and magazines discussed the feasibility of the NIR technique for cosmetic product property studies. Based upon the results of pioneers, we have pursued some work of the NIR instrument coupled with a probe module for skin measurement in vivo and vitro. In part I of this paper, the specific Near Infrared spectroscopy instrument stability, human subject conditions and other parameters, which could affect the measurements reproducibility are discussed. Second derivative NIR spectra and Principle Components Analysis (PCA) are utilised for data interpretation. In part II of this paper, the relationship of human skin moisture and ageing, the gender information and finally, the discovery of penetration depth of NIR incident light on skin are reported. A theoretical penetration depth calculation equation is proposed. In part III, the study results of a couple of commercial skin care products effect will be described. The skin lotions were applied on human skin (in vivo) in order to exam the NIR feasibility to monitor the changes of moisture level. The results are consistently positive. From our primary study, it can conclude that the NIR is potentially a very powerful instrument for skin condition diagnostics, either for cosmetic and/or for medication purposes.

  • PDF

팬터그래프-전차선로 접촉부 영상처리 기술 개발 (Development of Image Processing Technology for Interaction between Pantograph and Overhead Contact Wire)

  • 김형준;박영;조용현;조철진;김인철
    • 한국전기전자재료학회논문지
    • /
    • 제22권12호
    • /
    • pp.1084-1088
    • /
    • 2009
  • The measurement of dynamic stagger in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. This paper is introduces a non-contact optical-based measuring instrument of a catenary system in electric railways. The instrument is implemented by utilizing a CCD (Charge Coupled Device) camera installed on the roof of a vehicle for vision acquisition and image processing techniques including the Canny edge detector and the Hough transform to detect contact wires and calculate dynamic stagger. To check the validity of our approach for the intended application, we measured stagger of a overhead wire of a Korea Tilting Train (TTX). The non-contact optical-based measurement system proposed in this paper performs real-time stagger measurement of an activated high-voltage contact wire. By results of this paper, the instrument should be applied to assess performance and reliability of newly developed electric railway vehicles.

측정도구의 심리계량적 속성 2: 구조타당도, 내적일관성 및 교차문화타당도/측정동일성 (Psychometric properties of an instrument 2: structural validity, internal consistency, and cross-cultural validity/measurement invariance)

  • 이은현
    • 여성건강간호학회지
    • /
    • 제27권2호
    • /
    • pp.69-74
    • /
    • 2021
  • 측정도구의 구조타당도는 내용타당도 이후 가장 먼저 수행되어야 할 측정 속성이다. 이를 위해 국내 간호학에서는 주로 CFA를 사용하는데, CFA로 얻을 수 없는 정보들을 제시하는 IRT/라쉬 분석도 같이 적용해 볼 것을 추천한다. 구조타당도 이외에 내적일관성 및 교차문화타당도/측정동일성 또한 측정도구의 내적구조를 확인하기 위한 것이다. 국내 간호학 측정도구 연구에서 교차문화타당도/측정동일성에 대한 검증은 거의 찾아볼 수 없는 상황이다. 따라서 앞으로는 이에 대한 평가도 시행되기를 바란다.

Vision System을 이용한 사출제품의 길이 측정용 시각검사 System 개발 (The Development of Visual Inspection for Length Measurement of Injection Product Using Vision System)

  • J.Y. Kim;B.S. Oh;S. You
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.126-134
    • /
    • 1997
  • In this study, We made visual inspection system using Vision Board. It is consist of an illuminator (a fluorescent lamp), image input device (CCD (Charge-Coupled Device) camera), image processing system(Vision Board(FARAMVB-02)), image output device (video monitor, printer), and a measuring instrument(TELMN1000). Length measurement by visual inspection system make use of 100mm guage block(instead of calculating distance between a camera and a object). It measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measure- ment of a injection. A measuring instrument used to ompare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument with visual inspecion system using length factor of 100mm gauge block. We find that maximum error of length is 0.55mm when it compar with the measuring value of two devices(FARAMVB-02, TELMN1000). Program of visual inspection system is made up Borland C++3.1.

  • PDF

하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구 (A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage)

  • 백종석;김치영;이기성;강현웅;송재현
    • 한국방재안전학회논문집
    • /
    • 제13권4호
    • /
    • pp.65-74
    • /
    • 2020
  • 지속가능한 하천수 관리를 위해서는 연속적이고 정확한 하천수 사용량 계측자료가 필요하다. 하천수 사용지점별로 적용가능한 계측 방법이 상이하나, 일정규모 이상의 주요 개수로 지점에서는 보다 정밀한 직접 계측방법이 요구된다. 하천수 사용자는 사용량 계측을 위해 적정한 직접 계측방법을 선정해야 하는데, 이에 대한 표준 및 검증 연구가 부족한 실정이다. 본 연구에서는 만경강 상류의 시험유역에 직접 계측방법인 수위-유량관계법, 초음파법, 전자파법을 적용하였고, 계측방법별로 산정된 유량자료간의 절대오차 비교를 통해 계측자료의 정확도를 비교 평가하였다. 점단위 산정유량 비교시 초음파법이 실측값에 가장 근사한 결과를 보였다. 연속적인 계측을 통해 일단위와 월단위의 총량을 비교하였고, 초음파법과 전자파법이 정확도가 높은 것으로 나타났다. 본 연구의 결과를 토대로 초음파법과 전자파법이 수위-유량관계법에 비해 비교적 높은 비용이 투입되는 것을 감안하여 하천수 사용시설의 중요도에 따라 적정한 직접 계측방법을 선정할 수 있기를 기대한다.