• Title/Summary/Keyword: measurement equipment

Search Result 1,716, Processing Time 0.03 seconds

Evaluation of the Possession of Measurement and Analytical Instruments in Domestic Work Environment Monitoring Service Providers (II) (국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (II))

  • Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.182-192
    • /
    • 2014
  • Objectives: The aim of this study is to analyze the current status of possession of measurement and analytical instruments at work environment monitoring organizations and their relationships with human resources, including the number of professional engineers and evaluation scores resulting from evaluation programs in 2012. Materials: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency(KOSHA) and the Ministry of Employment and Labor(MoEL) during the evaluation program for 2012. Data for 11 monitoring instruments and nice pieces of analytical equipment were collected from 103 organizations. Additional data such as the type of service provides and the number of professional engineers employed were also recorded by the inspectors. Evaluation scores could be acquired from KOSHA. Results: Comprehensive Occupational Health Service Providers showed good operation quality, while University or Hospital Subsidiary and Work Environment Monitoring Organizations recorded relatively poor results. Evaluation scores correlated well with the possession of measurement instruments and human resources for each organization. High yields provided by professional engineers also showed statistically-associated contributions to evaluation scores and monitoring instrument possession. Compared with monitoring instruments, the amount of analytical equipment had little positive impact on organizations' competence. Conclusions: The evaluation results for domestic monitoring organizations revealed that human resources, possession of instruments, and the quality of employees were critical factors for operating the corporations. Each organization should give considerable effort to improving their ability to strengtheninternal quality, resulting in high-yield production for workers and employers by providing improved workplace monitoring services.

The Study on Measuring the Impedance of the Noise Source (잡음원의 임피던스의 측정에 관한 연구)

  • 박병욱
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.53-56
    • /
    • 2000
  • An Electrical equipment is the noise source which makes a noise. So the optimally designed filter should be inserted in the equipment in order to reduce the noise. The noise source impedance is varied according to the frequency It effects on the CE noise. Knowing the magnitude of its impedance and inserting an EMI filter in the equipment we can estimate the insertion loss of the filter. SO it helpful in designing the EMI filter. The measurement method of a noise source impedance is proposed and verified by experiment.

  • PDF

Circulation Effect of the Transparent Insulated Opaque Envelopes (투명 단열외피를 통한 환기효과에 관한 연구)

  • Kim, S.H.;Kim, S.J.;Lee, S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.31-43
    • /
    • 2000
  • A model house with a "Ondol" heating working with solar energy and supplied by circulation air was investigated both experimentally and theoretically, A calculation method was developed for interpreting the measured values and for comparing several variants, This calculation method together with the measurement result is presented in the following. The gain in energy of the collector(Trombe wall type with TWD) measured on a particularly selected winter day with plenty of radiation amounted to approximately 31 % of the total solar radiation.

  • PDF

Review of Membrane Tension Maintenance System for Membrane Structures through Membrane Tension Measurement (막장력 측정을 통한 막구조물의 장력 유지관리 시스템 검토)

  • Jin, Sang-Wook;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.39-45
    • /
    • 2016
  • Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

Development of Mobile Equipment for Local Risk Factors Detecting of Road Slope (도로사면의 국부적 위험요인 검지를 위한 이동형 장비 개발)

  • Kim, Yong-Soo;Jung, Soo-Jung;Ahn, Sang-Ro
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.938-945
    • /
    • 2008
  • Rockfall and landslide bring about a great social loss with loss of property such as obstruction of traffic and damage of the crops as well as casualty. The purpose of this study is to develop a mobile equipment for local risk factors detecting of road slope. The mobile equipment is designed to receive the sensing data from the measurement sensors, which are installed to detect the dangerous signs from the slopes, as loaded on a vehicle which is moving around to the places where the sensors are installed. In general, more than one mandatory data logger, which is very expensive, must be installed at each slope for the automatic measuring system, but in case of this developmental system, the inexpensive routine measurement can be performed regardless of the number of slopes due to the single unit of information gathering vehicle. This study is going to develop technologies that are expected to be applied to not only slope but also tunnel and bridges which might have the partial risk and need measuring.

  • PDF

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

Development of the Rotary Electrostatic Painting Equipment Using Air Turbine (공기 터빈을 이용한 회전형 정전 도장기기의 개발)

  • Lee, Chan;Cha, Sang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.684-690
    • /
    • 2003
  • A new electrostatic rotary atomizing painting equipment using air turbine was developed. Based on the overall design requirements of painting equipment basic design specifications of the equipment parts such as air turbine and atomizing disk are defined from the present conceptual design model. Air turbine is designed with the section profile of NACA airfoil, and its internal flow field is analyzed by commercial CFD code. Atomizing disk is designed to achieve the ligament type spray of paint with the use of visualization technique. Various experiments and tests are conducted to investigate the spray and the transfer characteristics of newly-designed painting equipment, and the measurement results are compared with the those of conventional painting equipments.

  • PDF

Design and Fabrication of Test Equipment for mass production of Automatic Test Equipment(ATE)

  • Kim, Dong-Il;Choi, Kyung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.8
    • /
    • pp.1-7
    • /
    • 2017
  • In this paper, we proposed the test equipment that can perform separate performance tests to mass-produce the Automatic Test Equipment. Until now, the performance test of the ATE has been performed after it has been assembled perfectly. It is possible to perform the performance test only when the external device manufacturing and setting of measurement resources and the internal wiring work have been completed. So we have been studying test equipment that separately tested the switching devices that played a key role in the performance of the ATE. To build the test equipment, we reviewed the circuit card assemblies that make up the switching devices. We designed a test equipment that satisfies the performance test and apply the completed test equipment to the actual production process to analyze whether it was effective in improving the time and workability of the performance test. The test equipment has the advantage that it can be used universally in the mass production process of ATE with the same type of switching device.