• 제목/요약/키워드: measurement development

검색결과 6,881건 처리시간 0.038초

차량탑재형 HFPD의 개발 (The Development of HFPD System for Mibile-loading Vehicles)

  • 김덕근;임장섭;여인선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

적외선 점광원 탐지장비의 최소탐지조도 측정 및 활용 (The Measurement and Application of the Minimum Detectable Irradiance for the Infrared Point Source Detection System)

  • 김현숙;양유경;박용찬
    • 한국광학회지
    • /
    • 제22권1호
    • /
    • pp.58-63
    • /
    • 2011
  • 외선 점광원 탐지장비의 탐지성능 예측을 위한 최소탐지조도(MDI)를 측정하고 실험결과를 제시하였다. 최소탐지조도 측정은 시준기를 이용하여 실험실 환경에서 수행할 수 있는 방법으로 구현하였으며 측정에 따르는 시험조건 및 절차를 상세히 기술하였다. 또한 최소탐지조도 측정 결과를 이용하여 분석한 적외선 탐지장비의 최대탐지거리 예측결과를 제시하였다.

초소형 스프링 정밀 측정을 위한 디지털 영상 처리 시스템 개발 (Development of System based on Digital Image Processing for Precision Measurement of Micro Spring)

  • 표창률;강성훈;전병희
    • 소성∙가공
    • /
    • 제11권7호
    • /
    • pp.620-627
    • /
    • 2002
  • The purpose of this paper is the development of an automated measurement system for micro spring based on the digital image processing technique. This micro spring can be used in various engineering applications such as filament, load bearing springs, hard disk suspension and many others. Main functionality of the micro spring inspection system is to measure the representative pitch of the micro spring. The derivative operators are used for edge detection in gray level image. Measurement system developed in this paper consisted of new auto feeding mechanism to take advantage of air pressure. In the process of development of the micro spring inspection system based on the image processing and analysis, strong background technology and know-how have been accumulated to measure micro mechanical parts.

비침습 연속혈당 모니터링 기술동향 (Trends in Non-invasive Continuous Glucose Monitoring Technology)

  • 김종덕;김봉규
    • 전자통신동향분석
    • /
    • 제36권5호
    • /
    • pp.9-20
    • /
    • 2021
  • A technology to replace the traditional blood sampling method for glucose monitoring has been sought for a long time. It is now possible to measure the blood glucose change rate continuously for more than 24 hours using a minimally invasive method that does not involve blood collection. Furthermore, various technology development efforts are being made for innovative diabetes management through intermittent or continuous blood glucose monitoring in a non-invasive manner. In this paper, we present an overview of diabetes and the need for continuous blood glucose measurement techniques., and then introduce various non-invasive blood glucose measurement techniques currently being studied. In addition, through research and analysis of the recent commercialization development status of minimally invasive, non-invasive, and wearable continuous blood glucose measurement technologies, we examine global development trends of future technologies.

학습조직화 측정도구 개발을 위한 연구 (A Study on the Development of the Learning Organization Measurement)

  • 정석희;이경선;이명하;김인숙
    • 간호행정학회지
    • /
    • 제9권1호
    • /
    • pp.75-88
    • /
    • 2003
  • Purpose : The Purposes of this study was to develop a learning organization measurement for nurses, and to test the validity and reliability of the measurement. Method : This study was conducted through 3 phases -theoretical framework choice, measurement items selection, and the testing of validity and reliability. In order to test reliability and validity of the measurement, data were collected from the 261 nurses, working in the 1 hospital with more 800 beds. The data obtained were analyzed by SPSS for Window program using percentages, Factor Analysis, Cronbach's alpha coefficients. Result : As a result of the study, 2 scales -Learning Organization Building Scale, and Knowledge Management Process Scale- were developed. Learning Organization Building Scale was consisted of 23 items, 5 factors. 5 factors explained 60.26% of the total variance, and the Cronbach's alpha of this scale was .8807. Knowledge Management Process Scale was consisted of 17 items, 4 factors. 4 factors explained 66.14% of the total variance, and the Cronbach's alpha of this scale was .9147. Conclusion : The Study supports the validity and reliability of the scales. Therefore, these scales can be effectively utilized for many researches about Learning organization of Nurse, and Nursing organization in the Hospital Setting.

  • PDF

2차원 영상 정보를 이용한 3차원 위치 측정 알고리즘 개발 (Development of a 3-D Position Measurement Algorithm using 2-D Image Information)

  • 이준호;정성호;김동현
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.141-148
    • /
    • 2013
  • There are several problems in the conventional 2-D image processing and 3-D measurement systems. In the case of the 2-D image processing system, it is not possible to detect elevation data. In a 3-D measurement system, it requires a skillful operator and a lot of time for measuring data. Also, there exist data errors depending on operators. The limitation of detecting elevation data in the 2-D image processing system can be solved by laser diodes. In this study an algorithm that measures the accurate data in a subject face to be detected by combining laser diodes and a commercial CCD camera is developed. In the development process, a planar equation is developed using laser diodes and the equation is used to obtain a normal vector. Based on the results, an algorithm that transforms commercial CCD camera coordinates to 3-D coordinates is proposed. The completed measurement method will be applied to replace a manual measurement system for vehicle bodies and parts by an automated system.

Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

  • Lim, Seon Hee;Kim, Seong Heon
    • Clinical and Experimental Pediatrics
    • /
    • 제65권2호
    • /
    • pp.73-80
    • /
    • 2022
  • A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Noninvasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to MS in terms of limitations such as validation and regular calibration and difficult to apply to infants, in whom Korotkoff sounds are not audible. The oscillometric method uses an automatic device that eliminates errors caused by human observers and has the advantage of being easy to use; however, owing to its measurement accuracy issues, the development of an international validation protocol for children is important. The hybrid method, which combines the auscultatory and electronic methods, solves some of these problems by eliminating the observer bias of terminal digit preference while maintaining measurement accuracy; however, the auscultatory method remains limited. As the age-related characteristics of the pediatric group are heterogeneous, it is necessary to reconsider the appropriate BP measurement method suitable for this indication. In addition, the mobile application-based BP measurement market is growing rapidly with the development of smartphone applications. Although more research is still needed on their accuracy, many experts expect that mobile application-based BP measurement will effectively reduce medical costs due to increased ease of access and early BP management.

승차감 평가를 위한 수직 방향의 인체 진동 모델 개발 (Development of Vertical Biomechanical Model for Evaluating Ride Quality)

  • 조영건;박세진;윤용산
    • 소음진동
    • /
    • 제10권2호
    • /
    • pp.269-279
    • /
    • 2000
  • This paper deals with the development of biomechanical model on a seat with backrest support in the vertical direction. Four kinds of biomechanical models are discussed to depict human motion. One DOF model mainly describes z-axis motion of hip, two and three DOF models describe z-axis of hip and head, and while nine DOF model suggested in this study represents more motion than the otehr model. Three kinds of experiments were executed to validate these models. The first one was to measure the acceleration of the floor and hip surface in z-axis, the back surface in x-axis, and the head in z-axis under exciter. From this measurement, the transmissiblities of each subject were obtained. The second one was the measurement of the joint position by the device having pointer and the measurement of contact position between the human body and the seat by body pressure distribution. The third one was the measurement of the seat and back cushion by dummy. The biomechanical model parameters were obtained by matching the simulated to the experimental transmissiblities at the hip, back, and head.

  • PDF

전략적 성과측정 지표 개발을 위한 사례 연구 (A Case Study on the Development of Strategic Performance Measures)

  • 최재영;최기준;권태형
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2000년도 추계학술대회 및 정기총회
    • /
    • pp.211-214
    • /
    • 2000
  • The paper presents a case study with application of a performance measurement questionnaire in analyzing a semi-conductor-related manufacturing company. The case may contribute to the development of strategic performance measurement system. The questionnaire contains considerable non-financial measurement indices as well as financial ones, which may strengthen the strategic aspect of measurement system. The strategy, actions, and measures have to be balanced through communication process in an organization. The result shows the usefulness of the congruence and consensus analysis of performance factors in effectively managing strategic action programs and identifying investment task areas to be targeted.

  • PDF

초기 재령 콘크리트의 모니터링을 위한 개선된 레일리파 속도 측정 기법 (Improved Rayleigh Wave Velocity Measurement Technique for Early-age Concrete Monitoring)

  • 신성우;윤정방;;송원준
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.97-103
    • /
    • 2006
  • A modified one-sided measurement technique is proposed for Rayleigh wave (R-wave) velocity measurement in concrete. The scattering from heterogeneity may affect the waveforms of R-waves in concrete, which may make the R-waves dispersive. Conventional one-sided techniques do not consider the scattering dispersion of R-waves in concrete. In this study, the maximum energy arrival concept is adopted to determine the wave velocity by employing its continuous wavelet transform. Experimental study was performed to show the effectiveness of the proposed method. The present method is applied to monitor the strength development of early-age concrete. A series of experiments were performed on early-age concrete specimens with various curing conditions. Results reveal that the proposed method can be effectively used to measure the R-wave velocity in concrete structures and to monitor the strength development of early-age concrete.

  • PDF