The Journal of the Institute of Internet, Broadcasting and Communication
/
v.21
no.5
/
pp.209-213
/
2021
For the human body shape information, body measurement techniques using a tape measure or image analysis are used. However, there is a demand for a method with high measurement accuracy and reproducibility while being simple. In this paper, domestic and foreign patent research related to body size measurement technology was conducted to identify the development trend of the related technology. WISDOMAIN DB was used to search for patents published in Korea, the United States, Japan, and Europe, and valid patents were derived by defining the technical scope of major and medium classifications and sub-categories. For the derived patents, patent trends by year, major applicants by country, and the status of technological fields were analyzed. In the field of body size measurement technology, the proportion of patent applications filed in Korea is high, indicating that Korea is leading the patent application in this field. Although the number of patent applications in the field of sensor-type measurement technology was not large, it has an advantage in measurement simplicity, so the development of related technology is expected to contribute to the improvement of measurement accuracy related to body composition analysis.
This study examined the measurement conditions of the texture profile analysis (TPA) experiments that are typically used to measure the physical properties of sausage. As the measurement conditions (compression ratio and cross-head speed) were changed, the significant differences between the values of textural parameters (hardness, adhesiveness, springiness, cohesiveness, chewiness) of samples changed. Furthermore, among the measurement conditions, there was more variation in the significant difference between the value of samples due to a change in the compression ratio than due to a change in the cross-head speed. The highest variation in significant difference was observed between the values of cohesiveness of samples due to changes in measurement conditions, whereas the lowest variation in significant difference was observed between the values of springiness of samples due to change in measurement conditions. Therefore, it is desirable to provide a clear basis for setting specific measurement conditions for TPA test, since significant differences in the values of textural parameters of samples were caused by differences in cross-head speed or compression ratio, not by a difference in samples, when analyzing the cohesiveness of sausage, especially.
The Journal of the Convergence on Culture Technology
/
v.9
no.1
/
pp.679-684
/
2023
Currently, large-scale and deep-depth excavation construction is being carried out in the vicinity of structures due to overdensity in urban areas in Korea. It is very important to secure the safety of retaining structures and underground structures for adjacent excavation work in urban areas. The safety of facilities is managed by introducing an automated measurement system. However, the utilization of the results of the automated measurement system is very low. Conventional evaluation techniques rely only on the maximum value of the measured data, and can overestimate abnormal behavior. In this study, we intend to improve the analysis technique for the automation measurement results. In order to identify abnormal behavior of facilities, a time-series analysis method for automated measurement data was presented. By applying a probability statistical analysis technique to a vast amount of data, highly reliable results were derived. In this study, the analysis method and evaluation method that can process the vast amount of data of facilities have been improved.
This paper measured the range of arm joint motion for Korean 54 male in twenties. The subjects are measured directly using Goniometer and angle gauge. The static measurement variables are seven and the dynamic measurement variables are thirteen. The anthropometric datum are analyzed by basic statistical analysis, correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach, 1978.
Organic carbon and nitrogen stable isotope ratios of particulate organic matter (POM) were determined at 7 stations (6 stations in Han river and Paldang dam outflow station) from May to October 2013, in order to understand the origin of POM at the Han river. ${\delta}^{13}C$ values of POM in four stations showed significant seasonal changes season, but ${\delta}^{15}N$ values were enriched in around Kyeongan stream (K). POC, PN and Chl-a concentration showed a similar seasonal pattern in Kyeongan stream, with an apparent decrease from July to August. POC and PN concentration has a higher correlation with Chl-a concentration in Kyeongan stream (K). ${\delta}^{13}C$ and ${\delta}^{15}N$ values of POM has a lighter value during lower Chl-a concentration peroid, compared to other seasons. Our results revealed that Kyeongan stream (K) seemed to be influenced by substantial amount of organic manure or fertilizer input in 2013, compared to the previous year (2012). These results suggest that the analysis of stable isotope ratios is a simple but useful tool for the identification of organic matter origin in aquatic environments.
There should be no problem in the measurement system for scientific quality management. In this paper, we want to correctly identify the factors that can affect the measurement results during the measurement process and identify what causes them when the measurement results cause problems in terms of location and variation. Variations in the measurement system are largely described in terms of location and dispersion. Location-related attributes are accuracy, stability, and linearity while dispersion-related attributes are reproducibility and repeatability. Analyzing the factors associated with dispersion is an R&R analysis, in which the size of repeatability and reproducibility is represented by a range of differences between multiple measurements and a range of differences between measurements, and 99% of dispersion is determined. Experimental design can also be used for measurement system analysis. Proper analysis is performed only when the factors causing the fluctuation, the worker and the product, are correctly identified as random or fixed factors.
Proceedings of the Korean Society of Precision Engineering Conference
/
1997.10a
/
pp.241-244
/
1997
This paper proposes Electronic Speckle Pattern Interferometry(ESPI) for the quantitative buckling analysis of square tube, which is unable to be measured with previous methods. The quantitative buckling analysis in elasticity is important part to study strain-stress analysis of thick-plated tube and fatigue analysis. However, it is unsolved problem with theory and previous experimental method. The merits of ESPI, Whole-filed measurement and high accurate 3D-displacement measurement make it possible to determinate the buckling analysis in elasticity quantitatively.
Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
/
v.13
no.1
/
pp.69-76
/
1995
This study is the 3-D precision deformation measurement of a bridge, obtain results of precision control points by GPS and 3-D measurement system and develope efficientlty technices which can solve precision 3-D analysis by CRP In the result, we could overcome the problems of former control point measurement in the way of the combination system of GPS and 3-D measurement system to positioning decision of reference points and control points. Then we could symplify old measurement process on the 3-D deformation analysis of a linear structure and complement parted analysis fault of measurement instrument.
Journal of the Korean Society of Clothing and Textiles
/
v.35
no.8
/
pp.933-945
/
2011
This research proposes a pattern design method for 24 pleated skirts in order to develop an automatic draft program for pleated skirts that will enhance fit and enable mass production. The research method and results are outlined as follow. 1. Three-dimensional body measurements were conducted on 30 randomly selected women in their 20s. By using 34 body measurement items and 6 types of calculations among the items, the items required in the designing of an original pleated skirt were extracted. They were then interpreted through correlation analysis, variance analysis, a t-test, linear regression analysis and multiple regression analysis. 2. An extra amount was added to the waist measurement and external capsule measurement according to the number of times the pleats coincided and the thickness of the fabric by the degree of polymerization of the horizontal cross section (the test of this research: 0.518mm). The extra amount of waist measurement was 3.6cm while the hip measurement was 4.3cm larger than the hip measurement combined with the external capsule measurement and the extra amount. 3. Based on the ${\pm}$standard deviation/2 as the average of the difference between the external capsule measurement and waist measurement, the subjects were classified into 3 somatotypes. Somatotype 1 presented an average total length of waist darts of 23.6cm while that of somatotype 2 was 26.2cm and that of somatotype 3 was 30.2cm. It has been confirmed that there is a significant difference among somatotypes in the total length of waist darts from the front center to the front side and the total length of waist darts from the side to the back center in terms of the average amount of waist darts for every 12 parts on the WL.
Journal of the Korean Society for Precision Engineering
/
v.27
no.4
/
pp.40-45
/
2010
Evaluation of uncertainty is an ongoing process that can consume time and resources. It can also require the service of someone who is familiar with data analysis techniques. Therefore, it is important for laboratory personnel who are approaching uncertainty analysis for the first time to be aware of the resources required. International inclination of measurement filed to guarantee the traceability and confidence of measurement results discards the error concept and instead analyzes the measurement uncertainty. In this paper, we analyzed the elements of measurement uncertainty on surface roughness test which are the important things in mechanical parts test. Repeat the test by 3 men, the measurement uncertainty could be calculated.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.