• Title/Summary/Keyword: measurement algorithm

Search Result 2,925, Processing Time 0.024 seconds

Downlink Signal Measurement Algorithm for WCDMA/HSPA/HSPA+

  • Kwon, Bit-Na;Lee, Eui-Hak;Hong, Dae-Ki;Kang, Sung-Jin;Kang, Min-Goo;Song, Hyoung-Kyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3040-3053
    • /
    • 2015
  • Wideband code division multiple access (WCDMA), high speed packet access (HSPA) and HSPA+ are third generation partnership project (3GPP) standards. These systems are the major wireless communication standards. In order to test the performance of WCDMA/HSPA/HSPA+ signal in a base station, the measurement hardware is required to the evaluation of the transmitted signals. In this paper, the algorithm for the performance measurement of the WCDMA/HSPA/HSPA+ is proposed. Also, the performance of the measurement algorithm is used to evaluate the generated signal by the WCDMA/HSPA/HSPA+ signal generator. Generally, the algorithm of normal modems cannot be applied to the measurement system because the signal measurement equipment needs to guarantee the high accuracy. So, the WCDMA/HSPA/HSPA+ signal measurement algorithm for the accurate measurement is proposed. By the simulation, it is confirmed that the proposed measurement algorithm has good performance compared with the specification. Therefore, the proposed algorithm can be usefully applied to verify the performance of the measurement using the simulation.

Signal Measurement Algorithm for 3GPP WCDMA Measurement Equipment (3GPP WCDMA모뎀 계측장비를 위한 신호계측 알고리듬)

  • Hong, Dae-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.7-15
    • /
    • 2011
  • In this paper, we implement measurement functionality for the 3GPP (Third Generation Partnership Project) WCDMA (Wideband Code Division Multiple Access) modem. Generally speaking, the receiving algorithms in normal modems cannot be used directly to the measurement system due to the lack of the measurement accuracy. In this paper, we propose the new measurement algorithm for precise 3GPP WCDMA signal measurements. In the measurement algorithm, 4-stage parameters estimation scheme is used. To improve the measurement accuracy, we increase the number of the received signal samples by interpolation. The proposed 3GPP WCDMA signal measurement algorithm can be used for verifying and implementing SoC/FPGA modem measurement systems.

HSPA/HSPA+ Terminal Signal Measurement Algorithm and Software (HSPA/HSPA+ 단말 신호 측정 알고리즘 및 소프트웨어)

  • Cho, Tae-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.37-44
    • /
    • 2011
  • HSPA(High Speed Packet Access)/HSPA+ is a combined 3GPP(Third Generation Partnership Project) standard of HSDPA(High Speed Downlink Packet Access) and HSUPA(High Speed Uplink Packet Access). The standard can provide the high speed multimedia service against the 3GPP release 99 standard. In order to test the 3GPP HSPA/HSPA+ terminal performance, the measurement hardware is required for the evaluate the transmitted signal of HSPA/HSPA+ terminals. Agilent Technologies and Innowireless produce the measurement equipments for HSPA/HSPA+ terminals. Generally speaking, the receiving algorithms in normal modems cannot be used directly to the measurement system due to the lack of the algorithm accuracy. In this paper, we propose the new receiver algorithm for precise measurement of 3GPP HSPA/HSPA+ terminal signal, and implement measurement functionality for performance measurement of the 3GPP HSPA/HSPA+ terminal by using software. The proposed 3GPP HSPA/HSPA+ signal measurement algorithm can be used for the commercial system through code execution speed optimization.

Dynamic Synchronous Phasor Measurement Algorithm Based on Compressed Sensing

  • Yu, Huanan;Li, Yongxin;Du, Yao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.1
    • /
    • pp.53-76
    • /
    • 2020
  • The synchronous phasor measurement algorithm is the core content of the phasor measurement unit. This manuscript proposes a dynamic synchronous phasor measurement algorithm based on compressed sensing theory. First, a dynamic signal model based on the Taylor series was established. The dynamic power signal was preprocessed using a least mean square error adaptive filter to eliminate interference from noise and harmonic components. A Chirplet overcomplete dictionary was then designed to realize a sparse representation. A reduction of the signal dimension was next achieved using a Gaussian observation matrix. Finally, the improved orthogonal matching pursuit algorithm was used to realize the sparse decomposition of the signal to be detected, the amplitude and phase of the original power signal were estimated according to the best matching atomic parameters, and the total vector error index was used for an error evaluation. Chroma 61511 was used for the output of various signals, the simulation results of which show that the proposed algorithm cannot only effectively filter out interference signals, it also achieves a better dynamic response performance and stability compared with a traditional DFT algorithm and the improved DFT synchronous phasor measurement algorithm, and the phasor measurement accuracy of the signal is greatly improved. In practical applications, the hardware costs of the system can be further reduced.

An Algorithm for Discontinuous Surface Profile Measurement using Wavelength Scanning Interferometer (파장 주사 간섭계를 이용한 불연속면의 표면 형상 측정 알고리즘)

  • 우현구;강철무;조형석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.7
    • /
    • pp.507-514
    • /
    • 2003
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. Recently the shape measurement using interferometric principle is found to be a successful methodology among other visual or optical technologies. Especially, the measuring method using wavelength scanning interferometer(WSI) has a great advantage in comparison with other conventional jnterferometric methods in that the absolute distance from the reference surface can be directly obtained from the amount of jnterferometric phase change. However, the measurement methods using WSI proposed by other researchers have low measurement resolution so far because they can't measure fractional phase change. To avoid this shortcoming we propose a new algorithm in this paper, which can obtain a small amount of even fractional phase change by sinusoidal function fitting. To evaluate the effectiveness of the proposed sinusoidal function fitting algorithm, a series of measuring experiments are conducted for discontinuously shaped specimens which have various height. The proposed algorithm shows much more enhanced measurement resolution than other existing conventional algorithms such as zero crossing algorithm and Fourier transform algorithm.

Lightweight Algorithm for Digital Twin based on Diameter Measurement using Singular-Value-Decomposition (특이값 분해를 이용한 치수측정 기반 디지털 트윈 알고리즘 경량화)

  • Seungmin Lee;Daejin Park
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.3
    • /
    • pp.117-124
    • /
    • 2023
  • In the machine vision inspection equipment, diameter measurement is important process in inspection of cylindrical object. However, machine vision inspection equipment requires complex algorithm processing such as camera distortion correction and perspective distortion correction, and the increase in processing time and cost required for precise diameter measurement. In this paper, we proposed the algorithm for diameter measurement of cylindrical object using the laser displacement sensor. In order to fit circle for given four input outer points, grid search algorithms using root-mean-square error and mean-absolute error are applied and compared. To solve the limitations of the grid search algorithm, we finally apply the singular-value-decomposition based circle fitting algorithm. In order to compare the performance of the algorithms, we generated the pseudo data of the outer points of the cylindrical object and applied each algorithm. As a result of the experiment, the grid search using root-mean-square error confirmed stable measurement results, but it was confirmed that real-time processing was difficult as the execution time was 10.8059 second. The execution time of mean-absolute error algorithm was greatly improved as 0.3639 second, but there was no weight according to the distance, so the result of algorithm is abnormal. On the other hand, the singular-value-decomposition method was not affected by the grid and could not only obtain precise detection results, but also confirmed a very good execution time of 0.6 millisecond.

Application of Immune Algorithm for Harmonic State Estimation (전력시스템 고조파 상태 추정에서 면역 알고리즘 적용)

  • Wang Yong-Peel;Park In-Pyo;Chung Hyeng-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.12
    • /
    • pp.645-654
    • /
    • 2004
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic analysis measurement instruments is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using Immune Algorithm (IAs). This IA-HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using Immune Algorithm (IAs) in the HSE.

Optimal Measurement System Design by Using Band Matrix (밴드행열을 이용한 최적측정점선정에 관한 연구)

  • Song, Kyung-Bin;Choi, Sang-Bong;Moon, Toung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.133-136
    • /
    • 1987
  • This paper presents a new algorithm of optimal measurement system by using band matrix characteristic respectively for state estimation. A performance index of measurement system is established to reflect relation among measurement sets, probability of measurement failure and cost of individual meter installation. Selection ranking in the candidates of measurement sets is composed to guarantee the observability for any any single meter outage. Performance index sensitivity is introduced and recursive formula which based on the matrix inversion lemma used for selection. The proposed algorithm is composed of successive addition algorithm, successive elimination algorithm and combinatorial algorithm. The band matrix characteristic could save in memory requirements and calculate the performance index faster than earlier.

  • PDF

Absolute Temperature Measurement using White Light Interferometry

  • Kim, Jeong-Gon
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.89-93
    • /
    • 2000
  • Recently a new signal processing algorithm for white light interferometry was presented. In this paper, the proposed signal processing algorithm was applied for absolute temperature measurement using white light interferometry. Stability testing and absolute temperature measurement were demonstrated. Stability test demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe. The test also showed that the absolute temperature measurement system using white light interferometry is capable of obtaining the theoretical minimum detectable change (0.0005 fringe), which is consistent with the performance predicted by the proposed signal processing algorithm.

Image-based structural dynamic displacement measurement using different multi-object tracking algorithms

  • Ye, X.W.;Dong, C.Z.;Liu, T.
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.935-956
    • /
    • 2016
  • With the help of advanced image acquisition and processing technology, the vision-based measurement methods have been broadly applied to implement the structural monitoring and condition identification of civil engineering structures. Many noncontact approaches enabled by different digital image processing algorithms are developed to overcome the problems in conventional structural dynamic displacement measurement. This paper presents three kinds of image processing algorithms for structural dynamic displacement measurement, i.e., the grayscale pattern matching (GPM) algorithm, the color pattern matching (CPM) algorithm, and the mean shift tracking (MST) algorithm. A vision-based system programmed with the three image processing algorithms is developed for multi-point structural dynamic displacement measurement. The dynamic displacement time histories of multiple vision points are simultaneously measured by the vision-based system and the magnetostrictive displacement sensor (MDS) during the laboratory shaking table tests of a three-story steel frame model. The comparative analysis results indicate that the developed vision-based system exhibits excellent performance in structural dynamic displacement measurement by use of the three different image processing algorithms. The field application experiments are also carried out on an arch bridge for the measurement of displacement influence lines during the loading tests to validate the effectiveness of the vision-based system.