• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.03 seconds

Damage detection in plate structures using frequency response function and 2D-PCA

  • Khoshnoudian, Faramarz;Bokaeian, Vahid
    • Smart Structures and Systems
    • /
    • v.20 no.4
    • /
    • pp.427-440
    • /
    • 2017
  • One of the suitable structural damage detection methods using vibrational characteristics are damage-index-based methods. In this study, a damage index for identifying damages in plate structures using frequency response function (FRF) data has been provided. One of the significant challenges of identifying the damages in plate structures is high number of degrees of freedom resulting in decreased damage identifying accuracy. On the other hand, FRF data are of high volume and this dramatically decreases the computing speed and increases the memory necessary to store the data, which makes the use of this method difficult. In this study, FRF data are compressed using two-dimensional principal component analysis (2D-PCA), and then converted into damage index vectors. The damage indices, each of which represents a specific condition of intact or damaged structures are stored in a database. After computing damage index of structure with unknown damage and using algorithm of lookup tables, the structural damage including the severity and location of the damage will be identified. In this study, damage detection accuracy using the proposed damage index in square-shaped structural plates with dimensions of 3, 7 and 10 meters and with boundary conditions of four simply supported edges (4S), three clamped edges (3C), and four clamped edges (4C) under various single and multiple-element damage scenarios have been studied. Furthermore, in order to model uncertainties of measurement, insensitivity of this method to noises in the data measured by applying values of 5, 10, 15 and 20 percent of normal Gaussian noise to FRF values is discussed.

Exposure Assessment and Management of Ionizing Radiation (전리방사선 노출과 관리)

  • Chung, Eun-Kyo;Kim, Kab-Bae;Song, Se-Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.27-35
    • /
    • 2015
  • Objectives: To investigate safety and health management, conditions in factories or facilities handling radiation-generating devices and radioactive isotopes were reviewed in terms of regulations of radiation safety control in Korea. Radiation exposure levels generated at those facilities were directly measured and evaluated for establishing an effective safety and health management plan. Methods: Government organizations with laws and systems of radiation safety and health were investigated and compared. There are three laws governing radiation-related employment such as occupational safety and health acts, nuclear safety acts, and medical service acts. We inspected 12 workplaces as research objects:four workplaces that manufacture and assemble semiconductor devices, three non-destructive inspection workplaces that perform inspections on radiation penetration, and five workplaces in textile and tire manufacturing. Monitoring of radiation exposure was performed through two methods. Spatial and surface monitoring using real-time radiation instruments was performed on each site handling radiation generating devices and radioactive isotopes in order to identify radiation leakage. Results: According to the occupational safety and health act, there is no legal obligation to measure ionizing radiation and set dose limits. This can cause confusion in the application of the laws, because the scopes and contents are different from each other. Surface dose rates in radiation generating devices such as implanters, thickness gages and accelerators, which were registered according to nuclear safety acts, using surveymeters, and seven of 36 facilities(19.4%) exceeded the international standards for surface radiation dose of $10{\mu}Sv/hr$. Conclusions: The results showed that occupational health and safety acts require a separate provision for measuring and assessing the radiation exposure of workers performing radiation work. Like noise, ionizing radiation will also periodically be controlled by including it in the object factors of work-environment measurement.

Vehicular Pitch Estimation Algorithm with ACF/IMMKF Based on GPS/IMU/OBD Data Fusion (GPS/IMU/OBD 융합기반 ACF/IMMKF를 이용한 차량 Pitch 추정 알고리즘)

  • Kim, Ju-won;Lee, Myung-su;Lee, Sang-sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1837-1845
    • /
    • 2015
  • The longitudinal velocity is necessary for accurate vehicular positioning in urban environment. The pitch angle, which is a road slope, should be calculated to acquire the longitudinal velocity. However, it is impossible to consider very accurate pitch, when using a sensor and an algorithm. That's why process noise and positioning stimation error of IMU should be adjusted to the driving environment and fuse GPS, OBD data with ACF which consist of AKF, CF in this paper. Then, final pitch angle which is appropriate for driving environment is estimated by IMMKF in order to optimize the system model according to road slope models.

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Analysis of Dynamic Positioning System Based on Self-Tuning Control (자기동조 제어기를 이용한 위치확보 시스템에 관한 연구)

  • Sang-M.,Lee;Pan-M.,Lee;Sa-Y.,Hong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.2
    • /
    • pp.32-40
    • /
    • 1989
  • Dynamic ship positioning(DP) system is used to keep the position and heading of a ship, or a floating platform, above a pre-selected site on the seabed by using thrusters. This paper presents a control system based on filtering technique and optimal control theory. The planar motions of a vessel are assumed to consist of low frequency(LF) component and high frequency(HF) one. The former is mainly due to thrusters, current, wind and second order wave forces, while the latter is mainly due to first order oscillatory component of the wave force. Furthermore position measurement signals include the noise. By means of self-tuning filter and Kalman filter techniques, LF motion estimates and HF ones are seperately achieved from the position measurements of the vessel. The estimated LF motions are used as input to the feedback loops. The total thruster power is minimized using the Linear Quadratic Gaussian control theory. The performance of the vessel with the DP system is investigated by computer simulation.

  • PDF

Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector (비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가)

  • Park, Ji-Koon;Kang, Sang-Sik;Cho, Sung-Ho;Shin, Jung-Wook;Kim, So-Yeong;Son, Dae-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.

Acoustic Characteristics on the Adolescent Period Aged from 16 to 18 Years (16~18세 청소년기 음성의 음향음성학적 특성)

  • Ko, Hye-Ju;Kang, Min-Jae;Kwon, Hyuk-Jae;Choi, Yaelin;Lee, Mi-Geum;Choi, Hong-Shik
    • Phonetics and Speech Sciences
    • /
    • v.5 no.1
    • /
    • pp.81-90
    • /
    • 2013
  • During adolescence the mutational period is characterized by the changes in the laryngeal structure, the length of the vocal cords, and a tone of voice. Usually, adolescents at 15 or 16 reach the voice of adults but the mutational period is sometimes delayed. Therefore, studies on the voice of adolescents between 16 ~ 18 right after the mutational period are required. Accordingly, this paper attempted to provide basic data about the normal standard for patients with voice disorders during this period by evaluating the vocal characteristics of males and females between 16 ~ 18 with an objective device bycomparing and analyzing them by sex and age. The study was conducted on a total of 60 subjects composed of each 10 subjects of each age. The vocal analysis was conducted by MPT (Maximum Phonation Time) measurement, sustained vowels and sentence reading. As for /a/ sustained vowels, fundamental frequency, hereinafter referred to as $F_0$, jitter, shimmer, noise-to-harmonic ratio, hereinafter referred to as NHR were measured by using the Multi-dimensional voice program (MDVP) among the Multi-Speech program of Computerized Speech Lab (Kay Elemetrics). The sentence reading, mean $F_0$, maximum $F_0$ and minimum $F_0$ were measured using the Real-Time Pitch (RTP) Model 5121 among the Multi-Speech program of Computerized Speech Lab (Kay Elemetrics). As a result, according to sex, there were statistically significant differences in $F_0$, jitter, shimmer, mean $F_0$, maximum $F_0$, and minimum $F_0$; and according to age, there were statistically significant differences in MPT. In conclusion, the voice of the adolescents between 16 ~ 18 reached the maturity levels of adults but the voice quality which can be considered on the scale of voice disorders showed transition to the voice of an adult during the mutational period.

LABORATORY EXPERIMENTS OF OFF-AXIS MIRROR OPTICS OF ALUMINUM FOR SPACE INFRARED MISSIONS

  • Oseki, Shinji;Oyabu, Shinki;Ishihara, Daisuke;Enya, Keigo;Haze, Kanae;Kotani, Takayuki;Kaneda, Hidehiro;Nishiyama, Miho;Abe, Lyu;Yamamuro, Tomoyasu
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.359-361
    • /
    • 2017
  • We report our research on aluminum mirror optics for future infrared astronomical satellites. For space infrared missions, cooling the whole instrument is crucial to suppress the infrared background and detector noise. In this aspect, aluminum is appropriate for cryogenic optics, because the same material can be used for the whole structure of the instrument including optical components thanks to its excellent machinability, which helps to mitigate optical misalignment at low temperatures. We have fabricated aluminum mirrors with ultra-precision machining and measured the wave front errors (WFEs) of the mirrors with a Fizeau interferometer. Based on the power spectral densities of the WFEs, we confirmed that the surface accuracy of all the mirrors satisfied the requirements for the SPICA Coronagraph Instrument. We then integrated the mirrors into an optical system, and examined the image quality of the system with an optical laser. As a result, the total WFE is estimated to be 33 nm (rms) from the Strehl ratio. This is consistent with the WFEs estimated from the measurement of the individual mirrors.

Design of RF Digital Spectrum Analyser for Mobile Communication (이동 통신용 RF 디지털 스펙트럼 분석기 설계)

  • Woo, Kwang-Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.29-34
    • /
    • 2007
  • It is important to analyse the frequency spectrum for the measurement of modulated signal, distortion, and noise. The frequency spectrum analysis is performed by the execution of Radix-2 DIT DFT i.e. FFT algorithm. The discrete input signal converted by A/D converter from the input signal in time domain is mathematically transformed to the frequency spectrum by FFT algorithm. In this study, we design the digital spectrum analyser by the hardware based on the TMS320F2812 DSP and AD9244 converter, and by the software based on the C28x S/W modules. We can timely analyse the frequency spectrum in mobile communication system by the digital frequency analyser based on the high performance DSP and S/W modules. This real-time analysing capability is the important performance in the internet-based mobile communication server system.

Analysis of Topography by Real-Time Kinematic GPS Positioning (실시간 동적 GPS 측량에 의한 지형 해석)

  • 신상철;김정동;박운용
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.3
    • /
    • pp.263-272
    • /
    • 2001
  • For a high resolution real-time kinematic GPS surveying using carrier phase, positioning accuracy according to the OTF initialization was better than 1 cm with more than 5-minute initialization within 20 km baseline. Also, it is recommended that measurements be carried out when PDOP and RDOP can be kept less than 4.0 since the geometrical layout of satellites has a great influence on the positioning accuracy. After considering the initial conditions and measuring time zone for real-time kinematic GPS. post-processed continuous kinematic GPS and real-time kinematic GPS measurements have been carried out. A new system has been proposed to store measured data by using a program developed to store GPS data in real time and to monitor the satellite condition through controller at the time of measurement. As a result, it has been revealed that possible noise in surveying could be corrected and the accuracy could be improved.

  • PDF