• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.029 seconds

Ground Vibration Test for Korea Sounding Rocket - III (KSR-III의 전기체 모달 시험)

  • 우성현;김영기;이동우;문남진;김홍배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.441-447
    • /
    • 2002
  • KSR-III(Korea Sounding Rocket - III), which is being developed by Space Technology R&D Division of KARI(Korea Aerospace Research Institute) will be launched in late 2002. It is a three-stage, liquid propellant rocket which can reach 250 km altitude and will carry out observation of ozone layer and scientific experiments, such as microgravity experiment, and atmospheric measurement. KSR-III is believed to be an intermediate to the launch vehicle capable of carrying a satellite to its orbit. Space Test Department of KARI performed GVT(Ground Vibration Test) fer KSR-III EM at Rocket Test Building of KARI. GVT is very important for predicting the behavior of rocket in its operation, developing flight control program and performing aerodynamic analysis. This paper gives an introduction of rocket GVT configuration and information on test procedures, techniques and results of It. In this test. to simulate free-free condition, test object hung in the air laterally by 4 bungee cords specially devised. For the excitation of test object, pure random signal by two electromagnetic shakers was used and total 22 frequency response functions were achieved. Polyreference parameter estimation was performed to identify the modal parameters with MIMO(Multi-Input-Multi-Output) method. As the result of the test, low frequency mode shapes and modal parameters below 60Hz were identified

  • PDF

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave (탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.119-129
    • /
    • 2012
  • In the medical field, the hardening of tissues is one of important informations used in diagnosis or understanding progress of disease, a quantitative measuring method of hardening is important for objective diagnosis. It has been proposed MRE(Magnetic Resonance Elastography) method that measures an index of hardening, viscoelastic properties in a noninvasive. Because the S/N ratio of MRE images go down when measuring viscoelastic properties from local wavelength and local damping factor of a propagating wave in MRE method, methods using multiple phase MRE images have been examined to decrease the effect of noise. We propose a method measuring viscoelastic properties after Fitting a function for multiple phase MRE images in this research. This proposed method has a advantage to set up arbitrarily the variation rate of a space direction of viscoelastic properties or the spatial resolution of measuring values according to changing of the noise included in images, though it applies viscoelastic wave for multiple phase MRE images. We confirmed the effectiveness of a proposed method by experiment using simulation images and experiment using silicone-gel phantom.

A Study on the Effectiveness of JPEG2000 for Medical Image Compression (의료영상 압축을 위한 JPEG2000의 효율성 연구)

  • Jung, Jae-Ho;Shin, Jin-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.31-40
    • /
    • 2003
  • Purpose : In a PACS(Picture Archiving Communications System) environment, which is a very important component in a digital medical environment, the compression of digital medical images is a necessary and effective feature. In a current system where JPEG is applied to the compression of medical images, this study is to examine effectiveness and suitability when the JPEG2000, a more advanced compression algorithm for still images, is applied to the compression of medical images. In this thesis, we attempt to address the compressibility for effective clinical usage when compressing medical images, applying the objectivization of clinical evaluation as a function of compressibility. In the experiment al method, the compression was applied at a fixed rate using JPEG2000, and the n the result was compared with compressed images by JPEG. Method : For the performance evaluation, we choose SNR(Signal to Noise Ratio) measurement of an objective evaluation of definition and analyze a subjective evaluation by the ROC(Receiver Operating Characteristic) method. The results of the experiment showed that in the case of JPEG2000 there is hardly any distortion of images, even at high compression ratio(100:1), while regarding noise, the SNR remains around about 40dB, which is also relatively high. Before reading by reference to evaluative materials concerning objective compressed images, it is impossible to apply high compression to images : however, after reading, this can be applied to images that have already existed for some time.

  • PDF

Construction of 3-Axis Flux-gate Magnetometer for Attitude Control of Satellite (인공위성의 자세제어용 3-축 Flux-gate 마그네토미터 제작)

  • Son, De-Rac
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.182-185
    • /
    • 2006
  • In this work, we have constructed 3-axis flux-gate magnetometer for the attitude control of satellite. The constructed magnetometer shows uncertainty of ${\pm}1%$, noise level of $0.2nT/\sqrt{Hz}$ at 1 Hz under 1W power consumption. Environment test for satellite component, acceleration test and thermal cycle test were carried out. For the acceleration test, magnetometer was vibrated frequency ranging from 10 Hz to 1 kHz at 15 g (g : gravitational acceleration at earth), and for thermal cycle test, 4 times of thermal cycle were carried out temperature ranging from $-55^{\circ}C\;to\;+80^{\circ}C$ under vacuum of $1x10^{-6}Torr$.

Implementation of Multi-layer PCB Design Simulator for Controlled Impedance (제어된 임피던스용 다층 PCB 설계 시뮬레이터 구현)

  • Yoon, Dal-Hwan;Cho, Myun-Gyun;Lin, Chi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.12
    • /
    • pp.73-81
    • /
    • 2011
  • As high speed digital systems continue to use components with faster edge rate and clock speeds, transmission of the digital information, it can bring about many troubles. The increasing requirement for controlled impedance PCBs becomes both a critical success factor and a design challenge to implement a system. Especially, the noise sources in high frequency digital systems include the noise in power supply, ground and packaging, and they destroy the fidelity of signals. Therefore PCB design with impendence matching is needed to improve fidelity of signal in H/W. In this paper, we have developed an impedance control and analysis tool for multi-layer PCB design, and simulates the tracks controlled impedance with the test coupon. So, it can save the design time and support the economical PCB design.

Effect of Design variables of Rail Surface Measuring Device on Acoustic Roughness and Spectral Analysis (레일표면 측정장치의 설계변수가 음향조도 스펙트럼 분석에 미치는 영향)

  • Jeong, Wootae;Jeon, Seungwoo;Jeong, Dahae;Choi, Han Shin
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.440-447
    • /
    • 2017
  • Spectrum level for the acoustic roughness of wheels and rail surface should be periodically maintained under the limitation of ISO to reduce rolling noise of railway vehicles. Thus, in maintaining railway track, displacement sensor-based measuring devices are broadly used to measure the surface roughness and to perform spectral analysis. However, these measuring devices cause unexpected measuring errors since the displacement sensors are fixed at moving platforms and the main frame produces pitching motion during measurement. To increase the accuracy of the measured values, this paper has investigated the effects of design variables such as wheel base, additional wheels, and elastic deformation of wheels on the surface roughness and acoustic roughness spectrum.

Implementation of Low Noise Current Sensor using Low Pass FIR Filter (저역통과 FIR필터를 이용한 저잡음 전류 센서 구현)

  • Kim, Jeong-Hwan;Lee, Seong-Jin;Choi, Yong-geon;Han, Seong-Gye;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.499-502
    • /
    • 2017
  • The needs of efficient electricity use and current measurement for electrical safety have been increased. Hence, the current sensor is used, especially non-contact current sensor which can measure the current without blocking the circuit using hall effect. However, the accurate measuring of the current sensor is inhibited due to the inflow of various noises in this current sensor. In this article, a stronger current sensor against the noise is proposed using low pass FIR filter to the existing current sensor. FIR filter was designed to block the range over the certain frequency at the output of the current sensor to eliminate the external noises, and so on. As a result, more accurate and close measurements were possible.

  • PDF

Determination of Optimal Scan Time for the Measurement of Downstream Metabolites in Hyperpolarized 13C MRSI

  • Lee, Hansol;Lee, Joonsung;Joe, Eunhae;Yang, Seungwook;Choi, Young-suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.212-217
    • /
    • 2015
  • Purpose: For a single time-point hyperpolarized $^{13}C$ magnetic resonance spectroscopy imaging (MRSI) of animal models, scan-time window after injecting substrates is critical in terms of signal-to-noise ratio (SNR) of downstream metabolites. Pre-scans of time-resolved magnetic resonance spectroscopy (MRS) can be performed to determine the scan-time window. In this study, based on two-site exchange model, protocol-specific simulation approaches were developed for $^{13}C$ MRSI and the optimal scan-time window was determined to maximize the SNR of downstream metabolites. Materials and Methods: The arterial input function and conversion rate constant from injected substrates (pyruvate) to downstream metabolite (lactate) were precalibrated, based on pre-scans of time-resolved MRS. MRSI was simulated using two-site exchange model with considerations of scan parameters of MRSI. Optimal scan-time window for mapping lactate was chosen from simulated lactate intensity maps. The performance was validated by multiple in vivo experiments of BALB/C nude mice with MDA-MB-231 breast tumor cells. As a comparison, MRSI were performed with other scan-time windows simply chosen from the lactate signal intensities of pre-scan time-resolved MRS. Results: The optimal scan timing for our animal models was determined by simulation, and was found to be 15 s after injection of the pyruvate. Compared to the simple approach, we observed that the lactate peak signal to noise ratio (PSNR) was increased by 230%. Conclusion: Optimal scan timing to measure downstream metabolites using hyperpolarized $^{13}C$ MRSI can be determined by the proposed protocol-specific simulation approaches.

Dynamic Characteristics of Pressure Propagation According to Boundary Condition Changes in a Transmission Line (경계조건변화에 따른 동력전달관로의 동특성)

  • 나기대;유영태;김지환
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.75-82
    • /
    • 2002
  • Design for a quiet operation of fluid power system requires the understanding of noise and vibration characteristics of the system. It's not easy to analyze noise problem in hydraulic cylinder used in typical actuator Because they've got complex fluid dynamics. One of the fundamental problems associated with the hydraulic system is the pulsating flow in pipe lines, which can be tackled by the analysis under simplifying assumptions. The present study focuses on theoretic analysis and experimental study on the dynamics of laminar pulsating flow in a circular pipe. We analyze the propagation characteristics of the pressure pulse within a hydraulic pipe line taking into account the pulsating flow frequency variation. We also measure instantaneous pressure pulses within pipe line to identify the transfer functions. We conduct series of experiments to investigate the propagation characteristics of pressure pulse for various pressure of pulsating flow. The working fluid of the present study is ISO VG46 and the temperature ranges from 20 to $60^{\circ}$ with normal pressure at 4000kPa. The flow rate is measured by using an ultrasonic flow meter. Pressures at fixed upstream and downstream positions are measured concurrently. The electric signals of the pressure sensor are stored and analyzed using a system analyzer(PKE 983 series). The frequency is varied in the range of 10~500Hz. The Reynolds number is kept below 2,000. In the present study, boundary condition was varied by installing a surge tank and an orifice at the end of pipe. Experimental and theoretical results were compared each other under various boundary conditions.