• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.029 seconds

Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry

  • Kim, Jae-Hyung;Moon, Tae Hwan;Chae, Ju Byung;Hyung, Sungmin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.546-550
    • /
    • 2014
  • To investigate the minimum near-infrared ray intensity required (quantifiable threshold value) for consistent measurements of axial length (AL) using partial coherence interferometry (PCI), we attached two polarizing lenses (PL) to two types of PCI (IOLmaster, ALscan). The near-infrared ray intensity of PCI was modified by rotating the axis of one PL at intervals of 5 degrees. The right eye of each volunteer was measured three times and the AL and signal-to-noise ratio (SNR) was recorded five times for each measurement. Reduction of light intensity was theoretically estimated using Malus' Law. AL was measured consistently with both IOLmaster and ALscan until they reached 55 degrees (1.33 % of intensity) and 60 degrees (0.77%), respectively (P = 0.343, Log-rank test). In contrast, SNR decreased as light intensity decreased. In addition, to analyze media opacities that precluded measurement of AL, we retrospectively reviewed the medical records of patients unmeasurable by PCI (ALscan) from May to November 2013. Thirty-eight of 473 eyes (8.0%) could not be measured using ALscan due to media opacities, such as severe posterior subcapsular cataract (PSC, 11 eyes), hypermature cataract (9 eyes), and vitreous hemorrhage (18 eyes). The mean grades of vitreous haze and PSC were $7.72{\pm}0.96$ and $4.45{\pm}1.04$, respectively. In conclusion, up to 0.77-1.33% of near-infrared rays decreased, and AL could be measured consistently.

Implementation of Intelligent Measurement System of InterModulation Distorted RF Signals (지능형 누설왜곡전파신호 측정시스템 개발)

  • Kim, Dong-hyeon;Seo, Na-Hyeon;Park, Ki-Won;Rhee, Young-Chul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.27 no.2
    • /
    • pp.144-149
    • /
    • 2017
  • In this paper, we developed an intelligent and wideband RF-receiver module to represent a high dynamic range and good linearity characteristics up to 650MHz-2700MHz frequency band. and implemented an intelligent digital-RF- distorted signal measuring system for the RF distortion (intermodulation) signals. Broadband RF-receive module was designed to represent the optimized linear parameters of the receiver to meet the low noise and wide dynamic range. The designed intelligent digital-distortion(intermodulation) signal measument system measured by applying the 1MHz IF of third intermodulation signal of DUT and Measured data was recorded by program on the PC monitor with GUI interface. By variable up to 650MHz-2700MHz measured data showed up to -127.8dBc to -138dBc of the distortion (intermodulation) signal. And developed intelligent digital- distortion signal measurement system can be used to measure intermodulation distortion signal of wireless system widely.

Performance Analysis on Digital Phase Difference Measurement Techniques for Interferometer Direction Finder (인터페로미터 방향 탐지기의 디지털 위상차 측정 기법 성능 분석)

  • Kang, Jong-jin;Park, Sung-kyun;Roh, Ji-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1076-1082
    • /
    • 2018
  • This paper describes interferometer direction finder which measures the angle of arrival based on calculation of the phase difference of received radio signal from different antennas. Modern Electronic Warfare direction finder uses digital phase difference measuring techniques which have less effect on temperature variation and better performance under low Signal to Noise Ratio environment. In this paper, we analyze acceptable phase difference error for requirement of system's direction finding accuracy and introduce digital phase difference calculation techniques. We have investigated quantitative analysis on phase difference calculation according to sample number, SNR, interference injection. Through the simulation, frequency domain measurement technique is better performance than the time domain one at the environment of low SNR and interference injection. Proposed method can be used to determine the performance of interferometer direction finder.

Measurement System for Performance Evaluation of Acoustic Materials in a Small Water Tank (소형수조에서 음향재료의 반향음감소와 투과손실 측정시스템 구성)

  • Shin, Mi-Ru;Cho, Jung-Hong;Lee, Kyung-Teak;Kim, Jea-Soo;Jeon, Jae-Jin;Ham, Il-Bea;Kang, Chang-Gi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • Since the detection probability is critically dependent on the target strength (TS) in active sonar and on the radiated noise level (RNL) in passive sonar, the acoustic materials for echo reduction (ER) and transmission loss (TL) are widely used for the stealth of underwater targets. In this paper, a measurement system based on the small water tank, for the frequency range of greater than 30 kHz, is developed and verified using reference targets. In order to design the water tank and the geometry of test samples, a program is developed to calculate the arrival time of interfering signals due to the reflection from water tank walls and also due to the diffraction from the edge of the test samples. Considering all the interfering signals, an optimal experimental configuration for water tank and test samples is designed and used throughout the experiment. Next, the signal processing algorithms to estimate ER and TL are developed based on the measured propagation loss reflecting the geometric spreading characteristics of the transducer. Finally, a set of reference targets such as aluminium plate and perfectly reflecting plate are used in a small water tank to verify the developed measurement system.

A Neural Network and Kalman Filter Hybrid Approach for GPS/INS Integration

  • Wang, Jianguo Jack;Wang, Jinling;Sinclair, David;Watts, Leo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.277-282
    • /
    • 2006
  • It is well known that Kalman filtering is an optimal real-time data fusion method for GPS/INS integration. However, it has some limitations in terms of stability, adaptability and observability. A Kalman filter can perform optimally only when its dynamic model is correctly defined and the noise statistics for the measurement and process are completely known. It is found that estimated Kalman filter states could be influenced by several factors, including vehicle dynamic variations, filter tuning results, and environment changes, etc., which are difficult to model. Neural networks can map input-output relationships without apriori knowledge about them; hence a proper designed neural network is capable of learning and extracting these complex relationships with enough training. This paper presents a GPS/INS integrated system that combines Kalman filtering and neural network algorithms to improve navigation solutions during GPS outages. An Extended Kalman filter estimates INS measurement errors, plus position, velocity and attitude errors etc. Kalman filter states, and gives precise navigation solutions while GPS signals are available. At the same time, a multi-layer neural network is trained to map the vehicle dynamics with corresponding Kalman filter states, at the same rate of measurement update. After the output of the neural network meets a similarity threshold, it can be used to correct INS measurements when no GPS measurements are available. Selecting suitable inputs and outputs of the neural network is critical for this hybrid method. Detailed analysis unveils that some Kalman filter states are highly correlated with vehicle dynamic variations. The filter states that heavily impact system navigation solutions are selected as the neural network outputs. The principle of this hybrid method and the neural network design are presented. Field test data are processed to evaluate the performance of the proposed method.

  • PDF

Real-time Vital Signs Measurement System using Facial Image Data (안면 이미지 데이터를 이용한 실시간 생체징후 측정시스템)

  • Kim, DaeYeol;Kim, JinSoo;Lee, KwangKee
    • Journal of Broadcast Engineering
    • /
    • v.26 no.2
    • /
    • pp.132-142
    • /
    • 2021
  • The purpose of this study is to present an effective methodology that can measure heart rate, heart rate variability, oxygen saturation, respiration rate, mental stress level, and blood pressure using mobile front camera that can be accessed most in real life. Face recognition was performed in real-time using Blaze Face to acquire facial image data, and the forehead was designated as ROI (Region Of Interest) using feature points of the eyes, nose, and mouth, and ears. Representative values for each channel of the ROI were generated and aligned on the time axis to measure vital signs. The vital signs measurement method was based on Fourier transform, and noise was removed and filtered according to the desired vital signs to increase the accuracy of the measurement. To verify the results, vital signs measured using facial image data were compared with pulse oximeter contact sensor, and TI non-contact sensor. As a result of this work, the possibility of extracting a total of six vital signs (heart rate, heart rate variability, oxygen saturation, respiratory rate, stress, and blood pressure) was confirmed through facial images.

The Error of the Method of Angular Sections of Microwave Sounding of Natural Environments in the System of Geoecological Monitoring

  • Fedoseeva, E.V.;Kuzichkin, O. R.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.47-53
    • /
    • 2021
  • The article deals with the problems of application of microwave methods in systems of geoecological monitoring of natural environments and resources of the agro-industrial complex. It is noted that the methods of microwave radiometry make it possible, by the power of the measured intrinsic radio-thermal radiation of the atmosphere, when solving inverse problems using empirical and semi-empirical models, to determine such parameters of the atmosphere as thermodynamic temperature, humidity, water content, moisture content, precipitation intensity, and the presence of different fractions of clouds.In addition to assessing the meteorological parameters of the atmosphere and the geophysical parameters of the underlying surface based on the data of microwave radiometric measurements, it is possible to promptly detect and study pollution of both the atmosphere and the earth's surface. A technique has been developed for the analysis of sources of measurement error and their numerical evaluation, because they have a significant effect on the accuracy of solving inverse problems of reconstructing the values of the physical parameters of the probed media.To analyze the degree of influence of the limited spatial selectivity of the antenna of the microwave radiometric system on the measurement error, we calculated the relative measurement error of the ratio of radio brightness contrasts in two angular directions. It has been determined that in the system of geoecological monitoring of natural environments, the effect of background noise is maximal with small changes in the radiobrightness temperature during angular scanning and high sensitivity of the receiving equipment.

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

A Study on the Harmfulness of Silicon Oxide Dust and Measures for the Work Environment Improvement in Construction Sites (건설현장에서 발생하는 산화규소분진의 유해성 및 작업환경 개선대책에 관한 연구)

  • Hwang, Jeong-Suk
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.478-486
    • /
    • 2022
  • Purpose: Although the working environment is measured at the construction site, only a few noise and vibration that are typically exposed for each process are performed without measuring the working environment by segmenting the exposed harmful factors. Therefore, it is intended to find the harmfulness of silicon oxide dust, which is most exposed at construction sites, and the complementary points of improvement measures currently being implemented at construction sites. Method: The status was analyzed using the actual condition survey report issued by the Korea Occupational Health Corporation and the Korea Occupational Health Association and data from the work environment measurement institution, and compared and analyzed with the rules on work environment measurement of the Occupational Safety and Health Act. Result: The harmfulness of silicon oxide dust was identified and improvement measures were derived. Conclusion: It is expected that occupational diseases against silicon dust can be reduced if the harmfulness of silicon oxide dust at construction sites is derived and improvement measures are actively applied at the site.

Development of a Portable Hydrophone Array System (휴대용 수중청음기 배열 시스템의 개발)

  • Kim Bong-Chae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.178-183
    • /
    • 2006
  • A hydrophone away is used to measure spatial distribution in underwater sound field and to detect incoming direction of sound waves in the ocean. It is not usually convenient to handle the hydrophone away because of its extensive scale. And it is not easy to purchase the hydrophone away because of expensive price. A hydrophone logger combined with a hydrophone and data logger was developed to consist conveniently of a hydrophone away for use to receive underwater sound waves. And a hydrophone array system with the hydrophone loggers was developed. Main configurations of the hydrophone 1o99er and the hydrophone array system are introduced in this paper. Also we present some measurement results by the hydrophone logger in a water tank and measurement examples on ambient noise in the sea by the hydrophone away system. And we discuss some advantages in use of the hydrophone array system.