• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.026 seconds

Development of Contact Force Measurement Algorithm for a 3D Printing-type Flexible Tactile Sensor (3D 프린팅 방식 유연 촉각센서의 접촉력 측정 알고리즘 개발)

  • Jeong, Kyeong-Hwa;Lee, Ju-Kyoung;Lee, Suk;Lee, Kyung-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.583-588
    • /
    • 2015
  • Flexible tactile sensors can provide valuable feedback to intelligent robots regarding the environment around them. This is especially important when robots such as, service robots share a workspace with humans. This paper presents a contact force measurement algorithm of a flexible tactile sensor. This sensor is manufactured by a direct-writing technique, which is one 3D printing method, using multi-walled carbon nano-tubes. An analog signal processing circuit has been designed and implemented to reduce noise contained in the sensor output. In addition, a digital version of the Butterworth filter was implemented by software running on a microcontroller. Through various experiments, characteristics of the sensor system have been identified. Based on three traits, an algorithm to detect the contact and measure the contact force has been developed. The entire system showed a promising prospect to detect the contact over a large and curved area.

WMPS: A Positioning System for Localizing Legacy 802.11 Devices

  • Gallo, Pierluigi;Garlisi, Domenico;Giuliano, Fabrizio;Gringoli, Francesco;Tinnirello, Ilenia
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.2
    • /
    • pp.106-116
    • /
    • 2012
  • The huge success of location-aware applications has called for the rapid development of an alternative positioning system to the global positioning system (GPS) for indoor localization based on existing technologies, such as 802.11 wireless networks. This paper proposes the Wireless MAC Processor Positioning System (WMPS), which is a localization system running on off-the-shelf 802.11 Access Points and based on the time-of-flight ranging of users' standard terminals. This paper proves through extensive experiments that the propagation delays can be measured with the accuracy required by indoor applications despite the different noise components that can affect the result: latencies of the hardware transreceivers, multipath, ACK jitters and timer quantization. Key to this solution is the choice of the Wireless MAC Processor architecture, which enables a straightforward implementation of the ranging subsystem directly inside the commercial cards without affecting the basic DCF channel access algorithm. In addition to the proposed measurement framework, this study developed a simple and effective localization algorithm that can work without requiring any preliminary calibration or device characterization. Finally, the architecture allows the measurement methodology to be adjusted as a function of the network load or propagation environments at the run time, without requiring any firmware update.

  • PDF

A Novel Filtering Method Based on a Nonlinear Tracking Differentiator for the Speed Measurement of Direct-drive Permanent Magnet Traction Machines

  • Wang, Gaolin;Wang, Bowen;Zhao, Nannan;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.358-367
    • /
    • 2017
  • This paper presents a novel filtering method for speed measurements to improve the low-speed performance of the direct-drive permanent magnet traction machines for elevators. Based on the theory of nonlinear tracking differentiator (NTD), this method, which can act as a high performance filter of a raw speed signal, obtains a more accurate speed feedback signal when applying a low-resolution encoder. In addition, it can relieve the interference caused by the position derivative for speed sampling. By analyzing the frequency response of the NTD, the influence of its parameters on the performance of the speed filtering is investigated. Compared with different types of low-pass filters, the proposed method shows a shorter time delay and a stronger ability in terms of noise suppression when the parameters are selected carefully. In addition, when using the measured speed signal through a nonlinear tracking differentiator as the feedback of the system, the motor runs more steadily at low speeds. As a result, the riding comfort of a direct-drive elevator can be improved. The feasibility of the proposed strategy was verified on an 11.7kW elevator traction machine using a commercial inverter.

Development of a High Resolution Cinematic Particle Image Velocimetry and Its Application to measurement of Unsteady Complex Turbulent Flows (고분해능 Cinematic PIV 시스템의 개발과 비정상 복잡 난류유동측정에의 응용)

  • Kim, Kyung-Chun;Park, Kyung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.536-541
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector for a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. The correct velocity vector at the first step is found to be critical, so we apply a Multiple Correlation Validation(MCV) technique in order to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds the performance of the conventional high resolution digital PIV system using a $1K{\times}1K$ CCD camera.

  • PDF

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Earthwork Volume Calculation of Anchorage Underground Capacity Using Laser Scanner (레이저스캐너를 이용한 앵커리지 지하공동의 토공량 산정)

  • Choi, Seok-Keun;Kim, Dong-Yeun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.3
    • /
    • pp.21-27
    • /
    • 2010
  • When the capacity of underground caverns' structures is measured, a general surveying is difficult to decide an accurate section of irregular shape and a photographic surveying has problems on picture acquisition due to underground dusts, noise and lighting conditions, etc. The laser scanner system is being much used for 3-dimensional modeling such as topography, planimetric features and structures, etc. without a target by measuring arriving time of a laser pulse reflected after scanning the laser pulse and calculating space coordinates of the reflection position. Accordingly, the present research carried out section and earthwork volume measurement of a tunnel by using a laser scanner in underground anchorage excavation work that a bridge construction is being executed.

Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines (Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발)

  • 손수국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.38-44
    • /
    • 2002
  • This paper describes the development of a new voltage recorder for the voltage management of power distribution lines. The voltage characteristics and measurement problems for the power distribution lines are analyzed and the functions required for the recorder are discussed. Applying a dual-slope A/D converter with low noise characteristics the voltage measurement algorithm, design and implementation for the recorder are discussed. Finally, the voltage variations of long-duration over-voltages or under-voltages, and short-duration temporary interruption based on IEEE 1159 are analyzed. It is verified with the experiment.

A Development of Pulse Oximeter module for Measurement of $SpO_2$ (산소포화도 측정을 위한 모듈형 펄스 옥시메터 개발)

  • 이한욱;이주원;이종회;조원래;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.575-583
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the $SpO_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have been required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. Therefore we simplify the calculation algorithm for $SpO_2$. The implemented system have the high performance such an accuracy and a processing time than the traditional method.

  • PDF

A Study on Multi-Sensor System for Detection of Chronic Mild Stress (만성스트레스 검출을 위한 멀티 센서시스템 연구)

  • Lee, Ji-Hyeoung;Kim, Kung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1131-1135
    • /
    • 2010
  • The development of modern civilization result from the abundance of material. Yet modern people live with chronic mild stress. Excessive chronic mild stress leads to various diseases. From the risk of the disease in order to protect our bodies need to manage chronic mild stress. The purpose of this study is to inspection the effectiveness of detecting in chronic mild stress using the Multi-sensor system. The Multi-sensor system is designed that can be measure three kinds of vital signals of chronic mild stress for the detection. First Photoplethysmogram(PPG), second Electro Dermal Activity(EDA), third Skin Temperature(SKT). The ages and occupations exposed to chronic mild stress, people often use out of this system was applied to dairy products(Pen). In addition, vital signals that occur when the variety of noise was used to remove the accelerometer. Chronic mild stress by the analysis of measured vital signals from Multi-sensor system to the measurement information to a PC to a wireless transmission(Bluetooth). In this study, using Multi-sensor system writing conditions and a variety of situations in the movement to measure vital signals and measurement results verified the accuracy and reliability. Through this measure chronic mild stress in everyday life and managing to maintain will help more healthy lifestyle.

An 0.4nm Resolution Encoder-like Capacitive Displacement Sensor (0.4nm 해상도의 엔코더 타입 전기용량형 변위센서)

  • Kang, Dae-Sil;Kim, Moo-Jin;Moon, Won-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1450-1454
    • /
    • 2007
  • A Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) has been developed to measure displacements at high accuracy within a long measurement range. In this paper, we have worked on improving the performance and reliability of the sensor. The performance increase can be done by introducing the smaller electrode patterns of $4{\mu}m$ width. In order to improve the reliability of the sensor we have changed the electrode layers from chrome-gold to chrome-gold-chrome and re-design its supporting structure. The newly-designed sensor is fabricated and tested to show that its sensitivity is $35pF/{\mu}m$, which implies that its resolution may be 0.36nm if SNR (Signal-to-Noise-Ratio) is 80.1dB. It is about ten times of that $(3.14pF/{\mu}m)$ of its previous version with 10${\mu}m$ electrodes. The total measurement range remains the same as the previous one; 15mm. The calibration experiments show its improved performance and reliability.

  • PDF