Validation of Vibration and Stress Analysis Method for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program (APR1400 원자로내부구조물 종합진동평가프로그램 진동 및 응력해석 방법 검증)

  • Kim, Kyu Hyung;Ko, Do Young;Kim, Sung Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.308-314
    • /
    • 2013
  • The vibration and stress analysis program of comprehensive vibration assessment program(CVAP) is to theoretically verify the structural integrity of reactor vessel internals(RVI) and to provide the basis for selecting the locations monitored in measurement and inspection programs. This paper covers the applicability of the vibration and stress analysis method of APR1400 RVI CVAP. The analysis method was developed to use 3-dimensional detail hydraulic and structural models with ANSYS and CFX. To assess the method, the hydraulic loads and structural reponses of OPR1000 were predicted and compared with the measured data in the OPR1000 RVI CVAP. The results predicted with this method were close to the measured values considerably. Therefore, the analysis method was developed properly.

Optimal Design of Air-spring and Active Control of Vibration Isolation Table (공기스프링의 최적설계 및 방진 테이블의 능동 제어)

  • An, Chae-Hun;Kim, Ho-Sung;Yim, Kwang-Hyeok;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.909-914
    • /
    • 2006
  • Vibration isolation tables are mostly required in precise measurement and manufacturing system. Among the vibration isolation tables, an air spring is the most favorable equipment because of low resonant frequency and high damping ratio. However, it is difficult to design the air spring with the required stiffness and damping ratio. Futhermore, whenever conventional active control methods are applied to the air spring, it may be difficult to obtain effective control performance due to high nonlinearity of air spring. In this paper, the optimal design of the air spring is performed using genetic algorithm to bring out low resonant frequency and high damping ratio. Also, active control of the vibration isolation table with 3-DOF model is proposed using the adaptive control method. Through experiments, optimal design is shown to be effective. And performance of the proposed control method is verified to be better than those of the passive control method and the conventional active control methods.

  • PDF

The Feature Extraction of Partial Discharge Electromagnetic Wave utilizing Signal Processing Techniques (신호처리 기술에 의한 부분방전 방사전자파의 특징 추출)

  • 이현동;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2002
  • In recent years, diagnostic techniques have been investigated to detect a partial discharge(PD) in a high voltage electrical equipment. Because PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise, the accuracy and credibility of PD measurement might be influenced by surrounding interference. Using the technique of PD detection by electromagnetic wave, we have studied the characteristics of both PD and substation-in interference signal. Also, we propose a wavelet packet transform based technique to perform a feature extraction from the interference and PD signal and a classification of the extracted features. The results show that time-frequency characteristics between PD and interference can be obviously distinguished. It is helpful for the development of the insulation diagnosis technique.

Comparative Analysis of Channel Length Dependence of NBTI and CHC Characteristics in PMOSFETs (PMOSFET의 채널 길이에 따른 NBTI 스트레스와 CHC 스트레스의 신뢰성 특성 비교 분석)

  • Yu, Jae-Nam;Kwon, Sung-Kyu;Shin, Jong-Kwan;Oh, Sun-Ho;Lee, Ho-Ryung;Jang, Sung-Yong;Song, Hyung-Sub;Lee, Ga-Won;Lee, Hi-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.7
    • /
    • pp.438-442
    • /
    • 2014
  • Channel length dependence of NBTI (negative bias temperature instablilty) and CHC (channel hot carrier) characteristics in PMOSFET is studied. It has been considered that HC lifetime of PMOSFET is larger than NBTI lifetime. However, it is shown that CHC degradation is greater than NBTI degradation for PMOSFET with short channel length. 1/f noise and charge pumping measurement are used for analysis of these degradations.

The fabrication of Light Source for Fiber Optic Gyroscope (광섬유 자이로스코프용 광원 제작)

  • 정인식;안세경;배정철;최영규;홍창희
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.370-373
    • /
    • 2003
  • Superluminescent diodes(SLDs) are the optimum light sources for application in optical measurement systems such as fiber gyroscopes, optical time domain reflectometers, and to short and medium distance optical communication systems. The broadband characteristics of SLDs reduce Rayleigh backscattering noise, polarization noise, and the bias offset due to the nonlinear Kerr effect in fiber gyro systems. In this paper, in order to suppress lasing oscillation, we introduced a laterally tilted SCH(Separate Confinement Heterostructure)-SLD with a window region. An output power of 11mW has been achieved at 200mA injection current at 25$^{\circ}C$. At 120mA, parallel and perpendicular to the junction were 31$^{\circ}$${\times}$38$^{\circ}$.

  • PDF

Design and Fabrication of a Wideband Ground Impedance Meter (광대역 접지임피던스 측정기의 설계 및 제작)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Han, Ju-Seop;Gil, Hyoung-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

Acoustic Analysis of Exhaust Supersonic Jet From a Rocket Motor Using 2-D Axis-symmetric Computational Analysis (2차원 축대칭 전산해석을 이용한 초음속 로켓 제트 음향 해석)

  • Yang, Young-Rok;Jeon, Hyuck-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.9
    • /
    • pp.725-730
    • /
    • 2020
  • This study was conducted to reduce the computation time required for the computational acoustic analysis of the supersonic rocket jet plume. In order to reduce the computation time, computational acoustic analysis was performed assuming that the supersonic jet plume is a two-dimensional axis-symmetric problem. The results of computational acoustic analysis showed similar results to the acoustic load measurement results. Through this study, it was confirmed that the acoustic load prediction of the supersonic rocket jet plume can be predicted using a two-dimensional axis-symmetric computational analysis.

Optimal Design of an Antenna for the Detection of Partial Discharges in Insulation Oil (절연유중 부분방전 검출을 위한 안테나의 최적 설계)

  • Lee, Jung-Yoon;Jo, Hyang-Eun;Park, Dae-Won;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.309-314
    • /
    • 2013
  • This paper dealt with the radiated electromagnetic wave detection of partial discharge (PD) in oil for insulation diagnostics of oil-immersed transformers. Three types of electrode system were fabricated to simulate the insulation defects that could occur in oil-immersed transformers. Frequency components of radiated electromagnetic wave in oil was measured by broadband bi-conical antennas of 300 MHz~2 GHz and a spectrum analyzer of 9 kHz~3 GHz. Frequency component of electromagnetic waves from PD in oil were highly distributed at 500 MHz. From the result, a narrow-band monopole antenna with the center frequency of 500 MHz was fabricated. We could detect PD signal in insulation oil without an influence of external noise by a measurement system which consists of the prototype monopole antenna, a LNA (Low Noise Amplifier), an oscilloscope and a spectrum analyzer.

Dynamic Characteristics of High-speed Railway Steel Bridges (고속철도 강교량의 진동특성 분석)

  • Lee, Jung-Whee;Kim, Sung-Il;Kwark, Jong-Won;Lee, Pil-Goo;Yoon, Tae-Yang
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.632-637
    • /
    • 2007
  • The dynamic behavior of two steel bridges crossed by the Korean High Speed Train(KHST) has been investigated experimentally and the results are compared with the specification requirement of BRDM and other typical PSC Box bridge's responses. The investigated bridges are a 2-girder steel bridge of 1@40m span length(E-Won Bridge), 2@50m span length (Ji-Tan Bridge), and a PSC Box girder bridge of 2@40m span length (Yeon-Jae Bridge). A set of experimental tests were performed during operation of KHST, and a number of accelerometers, LVDTs and ring-type displacement transducers were utilized for measurement of three kinds of dynamic responses (acceleration, deflection, and end-rotation angle). Measured responses show that the vertical deflections and end-rotation angles of the three bridges are all satisfying the spec. requirement with large margin, but it was also found acceleration responses which are very close or exceed the limit value. Most of the excessive acceleration responses were found when the passing velocity of the KHST is close to the critical velocity ($V_{cr}$) which causes resonance. No noticeable differences of dynamic responses due to the different materials(steel or concrete) could be found within these experimental results.

Fuzzy Controller Design for Active Vibration Isolation System Using Air-spring (공기스프링을 이용한 능동 방진 시스템의 퍼지 제어기 설계)

  • Yang, Xun;An, Chae-Hun;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.185-190
    • /
    • 2007
  • In recent days, vibration isolation system is mostly required in precise measurement and manufacturing system to reduce vibration due to external disturbances and internal actuators. Among all the vibration isolation systems, air spring is widely used because of its low resonant frequency and high damping ratio. In this study, we first analyze the passive air-spring system using leveling valve, and then design the active vibration isolation system. Because the non-linearity of pneumatic characteristics, we try to design the fuzzy controller which is better than PID controller at complex and non-linear system, and then compare them both in experiment and simulation.

  • PDF