• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.03 seconds

Measurement of a Mirror Surface Topography Using 2-frame Phase-shifting Digital Interferometry

  • Jeon, Seok-Hee;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.245-250
    • /
    • 2009
  • We propose a digital holographic interference analysis method based on a 2-frame phase-shifting technique for measuring an optical mirror surface. The technique using 2-frame phase-shifting digital interferometry is more efficient than multi-frame phase-shifting techniques because the 2-frame method has the advantage of a reduced number of interferograms, and then takes less time to acquire the wanted topography information from interferograms. In this measurement system, 2-frame phase-shifting digital interferograms are acquired by moving the reference flat mirror surface, which is attached to a piezoelectric transducer, with phase step of 0 or $\pi$/2 in the reference beam path. The measurements are recorded on a CCD detector. The optical interferometry is designed on the basis of polarization characteristics of a polarizing beam splitter. Therefore the noise from outside turbulence can be decreased. The proposed 2-frame algorithm uses the relative phase difference of the neighbor pixels. The experiment has been carried out on an optical mirror which flatness is less than $\lambda$/4. The measurement of the optical mirror surface topography using 2-frame phase-shifting interferometry shows that the peak-to-peak value is calculated to be about $0.1779{\mu}m$, the root-mean-square value is about $0.034{\mu}m$. Thus, the proposed method is expected to be used in nondestructive testing of optical components.

Application of Phase-shifting Method using fourier Transform to Measurement of In-plane Displacement by Speckle Interferometry

  • Kim, Myung-Soo;Baek, Tae-Hyun;Morimoto, Yoshiharu;Fujigaki, Motoharu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.3
    • /
    • pp.171-177
    • /
    • 2005
  • Phase-shifting method using Fourier transform (PSM/FT) has been applied to measurement of in-plane displacement of a specimen. Thirty-two interference fringe patterns each of which has different phase of ${\pi}/16$ radian have been gathered from a specimen with in-plane displacement. Low-pass filtering by 2-D Fourier transform is used to suppress spatial noise of the fringe patterns. ${\alpha}-directional$ Fourier transform for PSM/FT is performed by use of the low-pass filtered 32 fringe patterns. Two kinds of specimens are used for experiment. One is a rectangular steel plate and the other one is a rectangular steel plate containing a circular hole at the center. In-plane displacement of each specimen is measured by PSM/FT, and calculated by finite element method (ANSYS) for comparison. The results are quite comparable, so that PSM/FT can be applied to measurement of in-plane displacement.

The Development of a Cuff for the Accuracy Enhancement of the Sphygmomanometer

  • Kim, Won-Ki;Shin, Ki-Young;Mun, Joung-Hwan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 2006
  • The purpose of this study is to develop a new cuff to improve the accuracy of blood pressure measurement, and to evaluate the performance of the developed system. We added a small bladder to the normal cuff, which we refer to as the double bladder system. The system that we developed for blood pressure measurement was based on the oscillometric method using a double bladder. This system was developed in order to reduce the oscillation noise and to amplify the signal of pure blood pressure. An oscillometric signal database based on the developed system was evaluated according to the ANSI/AAMI/SP10-1992 standard. The correlation coefficients between the cuff of the double bladder and the normal cuff were 0.98 for systolic pressure and 0.94 for diastolic pressure. The mean differences and the standard deviations between the average blood pressure obtained from a mercury manometer and that obtained from an automated sphygmomanometer were -0.7mmHg and 4.9mmHg for systolic, and -1.4mmHg and 5.4mmHg for diastolic pressure. We conclude that the proposed double bladder-based cuff system improves the accuracy of oscillometric blood pressure measurement. The developed system reduces the range of error by about $44{\sim}62%$ for systolic pressure and about $6{\sim}21%$ for diastolic pressure compared to the most recently developed, commercially available sphygmomanometers.

The Evaluation of Communication Distance Using Wireless MEMS Sensor in Building Structure (건축구조물에서 무선 MEMS 센서를 이용한 통신 거리 유효성 평가)

  • Lee, Jong-Ho;Cheon, Dong-Jin;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.93-102
    • /
    • 2017
  • Wireless MEMS sensors have common features such as wireless communication, data measurement, embedded processing, battery-based self-power, and low cost, and increased measurement effectiveness. Wireless MEMS sensors enable efficient SHM without interfering with location because there is no requirement for triboelectric noise and cumbersome cables. However, there is little research on the communication distance with sensors and data. For instance, existing researches have limited communication distance experiments in civil engineering bridges. It is also necessary to investigate the characteristics of dynamic behavior and the communication distance of architectural structures with different wireless transmission/reception environments. Therefore, in a building structure with walls and slabs instead of open spaces, MEMS sensors and data loggers were used as distance experiments where communication disturbance between the vertical slab and the horizontal wall could actually be communicated.

Inverse Reconstruction of Sectional Area in Nonuniform Ducts by Using the Acoustical Measurement (음파를 이용한 덕트 내 불균일 단면적의 역문제적 재구성)

  • 김회전;이정권
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.9-16
    • /
    • 2001
  • This paper deals with the inverse reconstruction of sectional area in nonuniform ducts by using the acoustical measurement. There have been many theoretical and experimental studies on the duct area reconstruction. In this research, the method using the impulse response function and area reconstruction algorithm was employed because of its mathematical and experimental simplicity. Based on the study results on the drawback of conventional impulse excitation method, a new measurement method is proposed, that uses the random noise source and the discrete inverse Fourier transform. It is found that the reconstruction errors of the present method is smaller than the conventional method. A random error analysis is performed in order to investigate the causes of reconstruction error and to clarify the applicable data range for area reconstruction.

  • PDF

Quantitative Measurement of the Glottal Area Waveform(GAW) in Unilateral Vocal Fold Paralysis (편측성대마비환자에서의 성문면적파형(Glottal Area Waveform)의 정량적 측정)

  • 최홍식;김명상;최재영;안성윤;이세영;홍정표
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.71-78
    • /
    • 1998
  • Type Ⅰ thyuroplasty in conjunction with arytenoid adduction is one of the excellent techniques in the treatment of unilateral vocal fold paralysis. But perioperative objective evaluation of the patients is difficult. With the development of the videostroboscopy and image analysis program, we could quantify the Glottal Area Waveform(GAW) in patients with unilateral vocal fold paralysis and investigated the relationship between the glottal area and aerodynamic and acoustic parameters. Eight female patients who were performed type Ⅰ thyroplasty in conjunction with arytenoid adduction and 5 females with normal vocal function were involved in this study. Preoperative and postoperative videostroboscopy and vocal function study wire performed. GAW was analysed quantitatively with image analysis program (Kay Stroboscope Image analysis, KSIP) Peak Glottal Area(PGA), Baseline Offset(BO), and Closing Phase(CP) were increased in patients with unilateral vocal fold paralysis and they were reduced after the operation. Mean flow Rate (MFR) was well correlated with the PGA in normal control group and unilateral vocal fold paralysis patients. Noise to harmonic ratio(NHR) was correlated with PGA only in preoperative unilateral vocal fold paralysis patients. In conclusion quantitative measurement of the GAW is useful method in evaluation of unilateral vocal f31d paralysis patients.

  • PDF

Structure and Physical Properties of Earth Crust Material in the Middle of Korean Peninsula(5) : Characteristic Measurement of Geophone using Free Impedance and Step Force Method (한반도 중부권 지각물질의 구조와 물성 연구(5) : Free impedance와 Step force법을 이용한 수진기의 특성측정)

  • 유영준;송무영
    • The Journal of Engineering Geology
    • /
    • v.4 no.2
    • /
    • pp.207-218
    • /
    • 1994
  • The natural constants of moving coil type geophone can be determined by free impedance and step force method. The former method was desirable for the measurement of natural frequency($f_o$), inertial mass(m) and damping factor($h_o$), but the latter method for sensitivity(G). In particular, the value by the latter method should be corrected for the noise by the long period movement of measurement device. The results of frequency characteristics from these constants operate the accelerometer and displacement system in the boundary of natural frequency.

  • PDF

The Design of the Feedback Control System of Electromagnetic Suspension Using Kalman Filter

  • Jo, Jeong-Min;Han, Young-Jae;Lee, Chang-Young
    • International Journal of Railway
    • /
    • v.4 no.4
    • /
    • pp.93-96
    • /
    • 2011
  • The basic element of the EMS suspension is the electromagnet system, which suspends the vehicle without contact by attracting forces to the rails at the guideway. The suspension of a vehicle by attractive magnetic forces is inherently unstable and consequently it is continuously adjusted by the strength of the suspending electromagnet from rail irregularity and bending of the guideway. In order to improve reliable tracking, it needs to get feedback signals without measurement delay time. In this paper the concept of feedback control system with Kalman Filter in EMS is proposed. The input signals in the feedback control system are an air-gap and an acceleration signal. The air-gap signal with noise from the gap sensor is transformed to the filtered air-gap signal y without measurement delay time by using Kalman Filter. The filtered air-gap signal is transformed to a relative velocity and a relative acceleration signal. Then it multiplies these values by gain matrix in order to get the actuator's reference voltage value. The simulation results show that the dynamic responses of the suspension system can be improved by reducing the influence of measurement delay time of air-gap signals.

  • PDF

Design of Solid-State Transmitter and Receiver for Active Array Radar System (능동 배열 레이더 시스템 구현을 위한 반도체형 송수신기 설계)

  • Lee, Yu-Ri;Kim, Jong-Pil;Lee, Soo-Ho;Jeong, Myung-Deuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1335-1342
    • /
    • 2010
  • This paper presents design and measurement result of S-band, $\bigcirc$ kW solid-state transmitter and receiver for active array radar system. Transmitter characteristics show 63 dB gain, 200 usec pulse width(max.), 10 % duty(max.) and 63 dB pulse to pulse stability. Receiver characteristics show 23 dB gain and 3.2 dB noise figure. Receiving mode for pulse network analyzer is used for pulse to pulse stability measurement. Measurement results satisfies all specification.

Spectrum Analysis of VHF/UHF PD in Simulated Transformer (모의 변압기의 VHF/UHF PD 스펙트럼 분석)

  • Kim, Duck-Keun;Kim, Jong-Seo;Lim, Yong-Bae;Lim, Jang-Seob;Moon, Chae-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF