• Title/Summary/Keyword: measurement Noise

Search Result 3,227, Processing Time 0.029 seconds

A Note on the Small-Sample Calibration

  • So, Beong-Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.2
    • /
    • pp.89-97
    • /
    • 1994
  • We consider the linear calibration model: $y_1={\alpha}+{\beta}x_i+{\sigma}{\varepsilon}_i$, i = 1, ${\cdots}$, n, $y={\alpha}+{\beta}x+{\sigma}{\varepsilon}$ where ($y_1$, ${\cdots}$, $y_n$, y) stands for an observation vector, {$x_i$} fixed design vector, (${\alpha}$, ${\beta}$) vector of regression parameters, x unknown true value of interest and {${\varepsilon}_i$}, ${\varepsilon}$ are mutually uncorrelated measurement errors with zero mean and unit variance but otherwise unknown distributions. On the basis of simple small-sample low-noise approximation, we introduce a new method of comparing the mean squared errors of the various competing estimators of the true value x for finite sample size n. Then we show that a class of estimators including the classical and the inverse estimators are consistent and first-order efficient within the class of all regular consistent estimators irrespective of type of measurement errors.

  • PDF

Design of Video Quality Assurance and Integrated Quality Management System using No Reference QoE (비 참조 QoE를 이용한 영상품질 측정 및 통합품질 관리 시스템의 설계)

  • Kim, Sang-Soo;Park, Dong-Soo
    • The Journal of Information Technology
    • /
    • v.12 no.3
    • /
    • pp.49-57
    • /
    • 2009
  • This Paper provides perceptual metrics for video quality based on properties of human visual system, and audio quality based on human audition. All metrics work without reference signals, allowing non-intrusive, in-service measurements. A simple and easy-to-learn user interface displays the metrics and saves them in popular file formats like CSV. In this paper, proposed method was able to various and corrective measurement for the multimedia service video quality. As that it was able to application to set up service guide line and the methode of measurement and system for the set up standardization of the high quality video service.

  • PDF

Study on the Observability of a Calibration System for a Parallel Tilting Table with Measuerment Operator (측정연산자에 의한 병렬기구 틸팅 테이블의 관측성에 관한 연구)

  • Park Kun Woo;Lee Min Ki;Kim Tae Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.795-803
    • /
    • 2005
  • This paper studies the observability of calibration system with a measurement operator. The calibration system needs a simple digital indicator to measure the mobile table movements with respect to the MC coordinate. However, it yields the concern about the poor parameter observability due to measuring only a part of the movements. We uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of an observation matrix. The number of identifiable parameter is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a 6-axis MC with parallel tilting table and the calibration results are presented. These results verify that all necessary kinematic parameters are observable and the calibration system has robustness to the noise using optimal calibration configurations.

Design & Analysis of an Error-reduced Precision Optical Triangulation Probes (오차 최소화된 정밀 광삼각법 프로브의 해석 및 설계)

  • Kim, Kyung-Chan;Oh, Se-Baek;Kim, Jong-Ahn;Kim, Soo-Hyun;Kwak, Yoon-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.411-414
    • /
    • 2000
  • Optical Triangulation Probes (OTPs) are widely used for their simple structure. high resolution, and long operating range. However, errors originating from speckle, inclination of the object, source power fluctuation, ambient light, and noise of the detector limit their usability. In this paper, we propose new design criteria for an error-reduced OTP. The light source module for the system consists of an incoherent light source and a multimode optical fiber for eliminating speckle and shaping a Gaussian beam Intensity profile. A diffuse-reflective white copy paper, which is attached to the object, makes the light intensity distribution on the change-coupled device(CCD). Since the peak positions of the intensity distribution are not related to the various error sources, a sub-pixel resolution signal processing algorithm that can detect the peak position makes it possible to construct an error-reduced OTP system

  • PDF

Static measurement of magnetostriction of FeCoGe/phenol composites (FeCoGe/페놀 복합체의 정적 자기변형 측정)

  • Park, K.I.;Na, S.M.;Shin, K.H.;Lim, S.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.577-580
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites, which is one of the magnetostrictive materials, measured at the external magnetic field. The measurement was carried out using the electrical-resistance strain gage, the wheaten's Bridge for eliminating the unnecessary voltage, and the lock-in-amp for signal amplification and noise filtering. When the external magnetic field was applied in the longitudinal the samples, the maximum strain of 120ppm was taken with regard to the 10wt.% phenol composite. This results indicate that the FeCoGe/phenol composites can be useful as an actuator because it has larger stain than the other solid state actuators such as piezo electric materials.

  • PDF

A Design of Real Time Measurement System for EMG Silent Period Under Window Base (윈도우 환경하에서 근전도의 실시간 Silent Period 측정 시스템 설계)

  • 강병길;김태훈;이영석;김덕영;김세동;김성환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.611-617
    • /
    • 2003
  • A mechanical or electrical stimulation to the mandibular symphysis during a maximal voluntary clenching of the teeth always produces a jaw jerk followed by a silent period (transient stops) in the masseteric EMG (electromyogram). Generally, a mechanical stimulation is followed by a single silent period, and an electrical stimulation is followed by multiple silent periods. In this paper, we propose a new algorithm for determining the duration of the masseter silent period. The decision approach in essentially based upon a segmentation algorithm consisted of variance filter, median filter and gaussian filter. The new adaptive digital notch filter using R-CLMS(reverse constrained least mean-squared) algorithm is proposed for the elimination of powerline(60Hz) noise. At the same time, we design a real time measurement system for the EMG silent period under Window base.

Experimental Methods for the Measurement of Damping Loss Factors (내부손실계수 측정을 위한 실험 방법)

  • 김관주;최승권
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1187-1192
    • /
    • 1999
  • The purpose of this study is to determine the most appropriate experimental method of the measurement of "damping loss factors" (DLF) for the statistical energy analysis(SEA) calculation. The successful prediction of vibration levels from the structure is critically dependent on the accurate estimation of DLF's not only in conventional vibration analysis but especially in SEA. Unforunately, calculation of accurate DLF is not an easy matter. So experimental methods are made use of for the DLF values. Three kinds of experimental methods for estimating DLF, i.e. decay rate method, half-power bandwidth method and power balance method, are presented and tests are carried out for the plate and the cylindrical shell examples. Pro and con of each methods is reviewed. Finally, calculated DLF values are used for vibration level estimation using commercial SEA software and compared with measured vibration data.tion data.

  • PDF

Measurement of Plate Vibration by Using Phase Signals (위상신호를 이용한 단순평판의 진동계측)

  • 함연수;김정수;김관주
    • Journal of KSNVE
    • /
    • v.10 no.6
    • /
    • pp.949-954
    • /
    • 2000
  • Applicability of the vibration signal phase for predicting the modal damping properties of structures is investigated. For uniform plates with different internal damping levels, the phase delay as a function of the frequency span as well as a function of the distance between the excitation and response measurement points are experimentally obtained. Dependence of the phase characteristics on the amount of structural damping is elucidated -more heavily damped plate shows notably reduced phase delay at intermediate distances. The experimental results compare favorably with analytical predictions, and show much promise for further refinement as a tool for estimating structural properties.

  • PDF

Measurement of Distortion Level of Loudspeaker using Adaptive Filter Algorithm (적응필터 알고리즘을 이용한 스피커의 왜곡율 측정)

  • Kim, Cheon-Deok;Ji, Seok-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.2
    • /
    • pp.125-131
    • /
    • 1994
  • This paper describes a method to measure the distortion level of loudspeaker using a LMS(Least Mean Square) adaptive filter. Conventional technique to measure the distortion level uses a band-pass filter with a sharp cut-off frequency characteristics. However. such the band-pass filter has a bed time response characteristics. On the other hand, the proposed method offers us an easy way to measure the specified harmonic distortion level with a small hardware. Moreover, our method is not affected by noise which has no correlation with the test signal, and the measurement can be carried out in a noisy environment. The effectiveness of the proposed method is confirmed by experiment using a loudspeaker in a noisy room.

  • PDF

The Evaluation of Effectiveness on Horizontal Ambient Vibration Measurement of Tall Building Using Wireless MEMS Sensor (무선 MEMS 센서를 이용한 초고층 건물 수평 상시진동 계측의 유효성 평가)

  • Lee, Jong-Ho;Cheon, Dong-Jin;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.51-58
    • /
    • 2018
  • Recently, measuring instruments for SHM of structures had being developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to its absence of triboelectric noise and elimination of the requirement for cumbersome cable. However, the research on the tall buildings with relatively small vibration levels is insufficient. Therefore, in this paper, we used the wireless MEMS sensor and iPad to compare and analyze the vibration measurements of three tall buildings and two towers.