• Title/Summary/Keyword: measured size

Search Result 6,878, Processing Time 0.033 seconds

Comparison of particle size distribution and particle number concentration measured by APS 3321 and Dust Monitor 1.108 (APS 3321과 Dust Monitor 1.108을 이용한 입자 크기분포 및 수농도 측정결과 비교)

  • Lim, Kyoung-Soo;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2009
  • The size distribution and number concentration of atmospheric aerosol were measured and compared using APS 3321 and Dust Monitor 1.108. The particle size distribution and number concentration measured by two devices were also compared at a particle generation system of standard PSL and fly ash. The number concentration of atmospheric aerosol measured by APS was higher than that by Dust Monitor in particle size range of less than $3.0{\mu}m$, but there was good accordance between them in particle size range of over $3.0{\mu}m$. In the particle generation system of PSL and fly ash, different measurement results were shown because the particle concentration was higher than that of atmospheric aerosol. The number concentration measured by Dust Monitor was higher than that by APS in most particle size ranges. However, the peak concentration of PSL particles measured by Dust Monitor was lower than that by APS. The difference of the collection efficiency in a scrubber by APS and Dust Monitor measurement was less than 10%, but in the particle size of $1.5{\mu}m$, it was over 20%.

  • PDF

Experimental Analysis on Particle Growth m TEOS/O2 Plasma Reactor (TEOS/O2 플라즈마 반응기에서 미립자 성장에 대한 실험적 분석)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.149-153
    • /
    • 2001
  • A study on the particle growth in $TEOS/O_2$ plasma was performed, and particle size and its distribution was measured by the electrical aerosol analyzer (EAA), light scattering particle size analyzer and the particle size was also determined by SEM. The effects of process variables such as total gas flow rate, reactor pressure, supplied power and initial reactant concentration on the particle growth were investigated. From the EAA results, the particle size distribution is divided into three groups of the cluster size and the small and large size particles. The particle size distribution measured by the light scattering particle size analyzer becomes bimodal, because the cluster size particles smaller than 20 nm in diameter cannot be detected by the light scattering particle size analyzer. The size of particles measured by the light scattering particle size analyzer is in good agreements with those by the SEM. Also we could understand that the particle formation is very sensitive to the changes of reactor pressure and reactant concentration. As the total gas flow rate increases, the particle size decreases because of the shorter residence time. As the reactor pressure, or the reactant concentration increases, the particle concentration increases and the particles grow more quickly by the faster coagulation between particles.

  • PDF

The Comparison of Ultrasonographic Size of Morton's Neuroma measured to Actual Size (Morton씨 지간 신경종의 초음파검사상 크기와 실제 크기의 비교)

  • Kim, J-Young;Lee, Kyung-Tae;Young, Ki-Won;Son, Sang-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.80-83
    • /
    • 2006
  • Purpose: To compare ultrasonographic size of morton's neuroma measured to actual size. Materials and Methods: Thirty-two (twenty-eight patients) of symptomic Morton's neuroma were measured by ultrasonography preoperatively and by manual method that designed by authors intraoperatively from January, 2002 to May, 2003. Two results were stastically compared by paired T-test. Results: Except one, all of cases were women and the mean age of patients was 50.6 years (32-62 years). The most common associated disease was hallux valgus deformity (17 cases). Six of Morton's neuromas located on second intermetatarsal space, sixteen of them did third intemetatarsal space and ten of neuromas located simultaneously second and third intermetatarsal space. The ultrasonographic size of neuroma averaged 3.48 mm and real size was 3.99 mm. The size checked by manual method was larger than by ultrasound with statical meaning. Conclusion: The size of Morton's interdigital neuroma checked by ultrasonography on plantar aspect is smaller than real size. If you checked Morton's interdigital neuroma size by ultrasonography, you can suspect that real size of Morton's interdigital neuroma is larger than that size.

  • PDF

Comparison of the Mercury Intrusion Porosimerty, Capillary Flow Porometry and Gas Permeability of Eleven Species of Korean Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.681-691
    • /
    • 2018
  • The typical methods of mercury intrusion porosimetry (MIP) and capillary flow porometry (CFP) were used to evaluate the pore size of cross-section of wood and the effect of the pore structure on the permeability of wood was analyzed in this study. The results of this study were as followings: The pore size of wood measured by CFP was larger than that measured by MIP except for Lime tree, Korean red pine and Paulownia. Among the three pore types of porous materials defined by IUPAC (through pores, blind pores, and closed pores), only through pores are related to permit fluid flow. MIP measures the pore size of both through pores and blind pores, while CFP measures the pore size of only constricted through pores. Therefore, pore size measured by MIP was not related to gas permeability, however pore size measured by CFP had a proportional relationship with gas permeability.

A Study on the Measurement of Elastic-Plastic Zone at the Crack Tip under Cyclic Loading using ESPI System. (전자스페클 간섭시스템을 이용한 피로하중을 받는 균열선단에서 탄소성 영역 측정에 관한 연구)

  • Kim, Kyung-Su;Shin, Byung-Chun;Shim, Chun-Sik;Park, Jin-Young
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.140-144
    • /
    • 2002
  • In this paper, the plastic zone size ahead of the crack tip of DENT specimen and the crack growth length under cyclic loading were measured by ESPI system. These results of the plastic zone size measured by ESPI system were compared with the plastic zone size proposed by Irwin. The results of tile crack growth length measured by it were also compared with them measured by the image analysis system. It is confirmed that it is possible to measure the plastic zone and crack growth length.

  • PDF

Updating Inspection Data to Estimate Probability of Failure (파괴확률 산정을 위한 검측 데이터의 확률적 업데이트)

  • Chung, Tae-Young;Park, Heung-Min;Lee, Hak;Kong, Jung-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.645-650
    • /
    • 2007
  • According to most studies, assessment of aging structure is trend to detect flaw size by sensor than using existing subjective evaluation by expert for objective evaluation. But Uncertainties existing in the sensor make difference between measured flaw size and actual flaw size, In this paper, Probability of Detection(POD) have been used to quantify the uncertainties and POD is updated by relationship measured flaw size and actual flaw size (Heasler, 1990), also we proposed probabilistic updating approach method to improve measurement accuracy(the difference of measured PDF and actual PDF) by using updated POD.

  • PDF

A Study on Manufacturing Problem Solving of Scaffold with Pore Using 3SC Practical TRIZ and Machine Learning (3SC 실용트리즈와 머신러닝을 이용한 기공을 가진 인공지지체 제조문제 해결에 관한 연구)

  • Lee, Song-Yeon;Huh, Yong Jeong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.25-30
    • /
    • 2019
  • In this paper, we have analyzed manufacturing problems of the scaffold with pores using FDM 3D printer and PLGA. We suggested the solutions using 3SC practical TRIZ. We selected the final solution used machine learning. We reduced number of experiments using most influential factor after analysis print factors. We printed the scaffold and measured pore size. We created the regression model using python tensorflow. The print condition data of measured pore size was used as training data. We predicted the pore size of printed condition using regression model. We printed the scaffold using the predicted the print condition data. We quantitatively compare the predicted scaffold pore size data and the measured scaffold pore size data. We got satisfactory result.

Size Distribution of Ambient Aerosol Measured at a Coastal Site in Jeju Island (제주도 해안가에서 측정된 에어로졸의 성분별 입경분포 특성)

  • 이기호;양희준;허철구
    • Journal of Environmental Science International
    • /
    • v.12 no.10
    • /
    • pp.1043-1054
    • /
    • 2003
  • During the period from April to September 2002, the size distributions of ambient aerosol were measured at the coastal site at Hamduk in Jeju Island. Na$\^$+/, K$\^$+/, Mg$\^$2+/, Ca$\^$2+/and Cl$\^$-/ exhibited mostly a bimodal coarse mode size distribution, while ammonium and sulfate were mainly in the fine size range, with maximum at around 0.54$\mu\textrm{m}$. The average molar concentration ratio of ammonium to sulfate for fine particles was equal to 2.0${\pm}$0.9. Nitrate was evenly found in both the coarse and fine modes. Elements like Al, Fe, Cu, Mg, Na, Ti, Sr and Mn were dominant in coarse particles, with the maximum at around 5.25$\mu\textrm{m}$. S and Pb were mainly in the submicrometer size range. Other elements with a fine and coarse modes were V, Ni, Cu, Ba and Mo. The patterns of the size distributions of trace elements measured at the downtown in Jeju City were very similar to those at the coastal site in Hamduk. However, the amplitude of size fractional concentrations at Jeju City was narrower than that at Hamduk. While the mass median diameters for the chemical species originated from the natural origin such as marine and crust were relatively large, those for ammonium, sulfate, S and Pb were very small.

An Experimental Study on Droplet Size according to Discharge Coefficient of Sprinkler Head (스프링클러 헤드의 방수상수에 따른 물방울 크기에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • The sprinkler system is a basic fire extinguishing system that uses water as an extinguishing agent. In order to evaluate the fire extinguishing performance of the sprinkler system, information such as the discharge angle, discharge speed, discharge pressure, flow rate, and water droplet size of the installed head are required. However, there is a lack of research on droplets size compared to other requirements. In this study, to evaluate the extinguishing characteristics of sprinkler system, the droplet size distribution was measured for various types of sprinkler heads actually used. The size of the droplet was measured using laser diffraction method. The 50% cumulative volume distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the Rosin-Rammler index value are presented. As a result of the fire simulation with FDS, it was confirmed that the performance difference occurs according to the water droplet size distribution even when the same amount of water is used. Therefore, the extinguishing performance of the sprinkler system should be evaluated considering the droplet size distribution according to the sprinkler head type.

A Study on the Prediction of the Drop Size Distribution of Pressure-Swirl Atomizer (압력식 스월 노즐의 액적 크기분포 예측에 관한 연구)

  • Cho, D.J.;Yoon, S.J.;Kim, D.W.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1996
  • A theoretical and experimental study was carried out on the prediction of drop size distribution of the pressure swirl atomizer. Drop size distribution was obtained by using maximum entropy formal ism. Several constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of the estimating source terms. In this study $D_{10}$ was only introduced into the formulation as a constraint. A drop size obtained by using linear Kelvin-Helmholtz instability theory was considered as an unknown characteristic length scale. As a result, the calculated drop size was agreed well with measured mean diameter, particularly with $D_{32}$. The predicted drop size distribution was agreed welt with experimental data measured wi th Malvern 2600.

  • PDF