• Title/Summary/Keyword: measured method

Search Result 22,621, Processing Time 0.05 seconds

Compensation Method of Current Measurement Error for Vector-Controlled Inverter of 2-Phase Induction Motor (2상 유도전동기용 벡터제어 인버터를 위한 전류측정 오차 보상 방법)

  • Lee, Ho-Jun;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1204-1210
    • /
    • 2016
  • The phase currents must be accurately measured to achieve the instantaneous torque control of AC motors. In general, those are measured using the current sensors. However, the measured current signals can include the offset errors and scaling errors by several components such as current sensors, analog amplifiers, noise filter circuits, and analog-to-digital converters. Therefore, the torque-controlled performance can be deteriorated by the current measurement errors. In this paper we have analyzed the influence caused by vector control of 2-phase induction motor when two errors are included in measured phase currents. Based on analyzed results, the compensation method is proposed without additional hardware. The proposed compensation method was applied vector-controlled inverter for 2-phase induction motor of 360[W] class and verified through computer simulations and experiments.

A Study on the Measurement of Water Content in Hydrogel Contact Lens by Gravimetric Method (중량측정법에 의한 하이드로젤 콘택트렌즈의 함수율 측정에 관한 연구)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.59-63
    • /
    • 2008
  • Purpose: The purpose of this study is to understand a relation of water content measurement with two different method, water removal method and dry method. Methods: 72 hydrogel contact lens containing various water content (ranged from 47% to 58%) were measured by the gravimetric method at 20$^{\circ}C$and 21% of the humidity. We weighed the dried test specimen at room temperature for 30 min after cooling. Results: In dry blotting method, the water content was measured to 47.43${\pm}$8.48%. The water contents was measured to 48.15${\pm}$8.36% with wet blotting condition. It was found that wet blotting method showed the higher water content of about 7% than dry blotting method. In water content with two dry methods, each of results was measured by 47.89${\pm}$8.06% and 49.56${\pm}$7.06%. In case of microwave method, the water content was measured significantly higher water content of about 1.67% than vacuum oven method. However, no statistical difference was found (p>0.05). Conclusions: In water removal method (Dry blotting method and Wet blotting method) to weigh hydrated test specimen, wet blotting method showed significantly higher water content than dry blotting method. Also in case of dry methods (vacuum oven and microwave) to weigh dry test specimen, water content of microwave method showed higher water content than vacuum oven method, but it should be noted that microwave oven method must be used carefully to measure accurateness on the specimen position and wave power.

  • PDF

Development of Method for Deciding Automatically Parameters of Water Quality Simulation Models (수질모형의 매개변수 자동보정 프로그램 개발에 관한 연구)

  • Song, Kwang-Duck;Paik, Do Hyeon;Lee, Yong Woon
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2006
  • Water quality simulation models include the difference between the measured and estimated values as an inevitable consequence because they represent the complicated natural phenomena as simplified mathematical equations. The major reason of the difference occurrence is due to the use of the imprecise values of the model parameters, but the parameter values are currently determined by the try and error method directly performed by humans. However, the use of this method requires many time and endeavor of humans, and generally does not obtain the most suitable parameter values. A method for deciding model parameter values is, therefore, developed in this study. The method minimizes the difference between the measured and estimated values and also distributes uniformly the measured values on the upper and lower sides of the line representing the estimated values. A user interface based on this method is also developed by using the Visual Basic 6.0 of Microsoft, and it can be operated in the environment of Windows 98/2000. In this study, the method for deciding model parameter values is applied for estimating the water quality of the stream Ko-heung. The results of the application show that the method, including its computer program, can effectively obtain the most suitable parameter values and also save many working time in comparison with the existing method directly performed by humans.

Measurement of Isochromatic Fringe Distribution of a TV Glass Panel by Use of Photoelastic 4-step Phase Shifting Method (광탄성 4단계 위상이동법을 이용한 TV유리패널의 등색프린지 분포측정)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Cho, Seong-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper presents the experimental results measured by photoelastic 4-step phase shifting method for the isochromatic fringe distribution in a TV glass panel. In the conventional photoelastic method, the isochromatic fringe orders are measured manually point by point. The 4-step phase shifting method uses four images obtained from a circular polariscope by rotating the analyzer to $0^{\circ},\;45^{\circ},\;90^{\circ}$, and $135^{\circ}$. In order to use the 4-step phase shifting method, the elements of a polariscope should be aligned to isoclinic direction at a point and/or along a line where isochromatic fringe distribution is measured. Experimental results obtained from the 4-step phase shifting method are compared with those measured by the Senarmont compensation method. Both results are well agreed. Then, isochromatic fringe distributions in the TV glass panel that is heat-treated before and after are compared. Maximum and minimum isochromatic fringe orders in the TV glass panel with before- and after-heat treatment are changed approximately two times.

Spatial Data Analysis using the Kriging Method

  • Jang, Jihui;Hong, Taekyong;NamKung, Pyong
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.423-432
    • /
    • 2003
  • The data observed at different positions are called the estimate of interested variable at new observation point on the Kriging utilize the space estimate technique, in which case there is correlation spatially. In this paper we provide the estimate for Variogram and Kriging methods as a field of kriging theory and dealt with actually measured data. And at the same time we forecast the amount of ozone that was not measured at this point by Kriging method and compared Ordinary Kriging method with Inverse Distance Kriging method.

Simple DC CAD model and parameter extraction method for HBT (HBT를 위한 간단한 DC CAD 모델과 파라메터 추출 방법)

  • 서영석;박용완
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.48-55
    • /
    • 1998
  • We propose a new static current source model and parameter extraction method for AlGaAs/GaAs HBT. The proposed model has 9 parameters describing internal currents and are experessed with the physically meaningful parameters.The proposed parameter extraction method uses the measured dC IV curves and does not need the gummel plt data and any optimization process. the constructed model based on the proposed method predicts the measured data well.

  • PDF

A Practical Method to Correct the Saturation Effect in XMCD Spectra

  • Kim, J.Y.
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.85-87
    • /
    • 2008
  • I report a simple method to correct the saturation effect in absorption spectra measured in total electron yield (TEY) mode. It does not require additional measurements of the X-ray penetration depth. In order to check the reliability of the method, X-ray magnetic circular dichroism (XMCD) spectra for polycrystalline Fe were measured at two different incident angles, and then processed with the method. The two resultant XMCD spectra were identical, and their sum rule analysis produced the ratios of orbital magnetic moment to spin magnetic moment, which were very close to the well-known value.

AC Losses of the HTS Pancake Coil by Using Electric Method (전기적 측정법을 사용한 팬케이크 코일에서의 교류손실 측정)

  • 이승욱;임형우;최명섭;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.37-40
    • /
    • 2003
  • This paper presents calculated and measured AC losses of the HTS pancake coil. Magnetic field in the HTS coil under operating conditions was calculated by FEM. Results of measured ac loss in 4-stacked short sample were used in the AC loss calculation. Various methods, such as, electric method, calorimetric method, wattmeter method, were used to measure the AC loss.

  • PDF

Measurement of Noise Parameters Using 6-Port Network (Invited Paper) (6-포트 회로망을 이용한 잡음 파라미터 측정)

  • Yeom, Kyung-Whan;Ahmed, Abdule-Rahman
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.2
    • /
    • pp.119-126
    • /
    • 2015
  • The information about noise parameters is essential in the design of low noise amplifier. In the past, the noise parameters were measured using an impedance tuner and noise figure analyzer. Recently, the authors proposed the method of measuring the noise parameters using the 8-port network without the aid of the mechanically driven impedance tuner. However, the 8-port method still requires the noise source and causes the complexity in the measurements. In this paper, a novel measurement method of the noise parameters without the noise source using 6-port network is proposed. Based on the proposed 6-port method, the noise parameters of 10 dB attenuator whose noise parameters can be theoretically determined were measured and the measured noise parameters are compared with those measured using the previous 8-port network method. As a result, the accuracy of the measured noise parameters using 6-port network is found to be comparable to the previous 8-port network method.

A Method Estimating Displacement using Measured Strain Response of Simply Supported Girder Bridges (단순지지 거더교의 실측 변형률 응답을 이용한 변위 추정 방법)

  • Jeon, Jun-Chang;Lee, Hee-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.18-24
    • /
    • 2016
  • This study presents a simple method which can estimate displacement using measured strain response of simply supported girder bridges. The basic concept of the present method is derived from a relation between displacement and strain, and is generalized by introducing analytical tool. Static and dynamic laboratory test are conducted on simply supported plate which is designed to respond dynamically similar to actual bridges to experimentally verify the present method, and displacement and strain are measured at the midpoint of specimen. Displacement estimated by using measured strain is well agreed with measured one. This study demonstrates that the present method is suitable for estimating displacement of real simply supported bridge, in which the installation of a displacement transducer at the fixed reference point is difficult.