• Title/Summary/Keyword: mean energy

Search Result 2,997, Processing Time 0.058 seconds

Correlation Between Fatigue Life of 2.2Ni-0.1Cr-0.5Mo Steel Accompanying Mean Stresses with Cyclic Strain Energy Density (평균응력을 동반하는 2.2Ni-lCr-0.5Mo강의 피로수명과 변형률에너지 밀도와의 상관관계)

  • Koh, Seung-Kee;Ha, Jeong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.167-174
    • /
    • 2003
  • Fatigue damage of 2.2Ni-1Cr-0.5Mo steel used fir high strength pressure tubes and vessels was evaluated using uniaxial specimens subjected to strain-controlled fatigue loading. Based on the fatigue test results from different strain ratios of -2. -i 0, 0.5, 0.75, the fatigue damage of the steel was represented by using a cyclic strain energy density. Mean stress relaxation depended on the magnitude of the applied strain amplitude. The high pressure vessel steel exhibited the cyclic softening behavior. Total strain energy density consisting of the plastic strain energy density and the elastic tensile strain energy density described fairly well the fatigue life of the steel, taking the mean stress effects into account. Compared to other fatigue damage parameters, fatigue life prediction by the cyclic strain energy density showed a good correlation with the experimental fatigue lift within a factor of 3.

Mean Flow and Variability in the Upper Portion of the East Sea Proper Water in the southwestern East Sea with APEX Floats

  • Lee, Homan;Kim, Tae-Hee;Kim, Ji-Ho;Seo, Jang-Won;Youn, Yong-Hoon
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.135-141
    • /
    • 2004
  • Drift data from 17 Argo profiling floats in the East Sea are used to understand the mean flow and its variability in the upper portion of the East Sea Proper Water (UESPW) (around 800 m). The flow penetrates into the Ulleung basin (UB) through two paths: an extension of the southward flowing of the North Korean Cold Water along the east coast of Korea and between Ulleung Island and Dok island. Flows at 800 m are observed in the range of from 0.2 to 4.29 cms-1 and the variability in the north of the UB is larger than that in the south of the UB. In the UB, cyclonic flows from 0.3 to 1.6 cms-1 are observed with the bottom topography. We found that the mean kinetic energy (MKE) and the mean eddy kinetic energy (EKE) are 1.3 and 2.1 cm2s-2 respectively.

Characteristics of Electron Transport in $SiH_4$ Gas used by MCS-BEq Algorithm (MCS-BEq 알고리즘에 의한 $SiH_4$ 기체의 전자수송특성)

  • Kim, Sang-Nam;Seong, Nak-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.159-162
    • /
    • 2006
  • In this paper energy distribution function in $SiH_4$ has been analysed over the E/N range 0.5${\sim}$300Td and Pressure value 0.5, 1.0, 2.5 Torr by a two-term approximation Boltzmann equation method and by a Monte Carlo simulation. The motion has been calculated to give swarm parameters for the electron drift velocity, diffusion coefficient, electron ionization, mean energy and the electron energy distribution function. The electron energy distribution function has been analysed in $SiH_4$ at E/N=30, 50Td for a case of the equilibrium region in the mean electron energy and respective set of electron collision cross sections. The results show that the deduced electron drift velocities, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients and mean energy agree reasonably well with theoretical for a rang of E/N values.

  • PDF

Nutrition survey of young children in a day care center in the low income area of seoul (서울 시내 변두리 저소득지역 유아원 어린이의 영양실태조사)

  • 이혜상
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.2
    • /
    • pp.37-50
    • /
    • 1986
  • A nutrition survey of 128 perschool children, 4 to 6 years old, in the Saemaul Youlgok day care center, located in one uplane, overpolulated, poor area of the city of Seoul, sponsered by the Korean Red Cross Society, was undertaken between August 21 and 31, 1984, to investigate dietary and nutritional status. RESULTS: Mean values of height, weight, arm circumference, girth of chest, and head circumference ranged from 95 to 100% of KIST mean. However, 4.8~14.2% of the subjects were assessed as undernourished in terms of 'weight for height'. Mean hemoglobin vcalue was 12.1±0.7gm%, and mean hematocrit value was 38.5±2.2%; 4.1% of the subjects were proven to be anemic according to the criterion of hemoglobin established by the ICNND. Mean urinary urea nitrogen/creatinine ratio was 11.4±3.8. Regarding mean energy and nutrient intake, the following percentages had intakes below two-thirds of the 1985 RDAs: 28.8% of children, for protein; 48.8% of children, for iron; and 28.8% of children, for calcium. About 25% of children had vitamin A intake below one-third of the recommended allowance. Carbohydrate provided 71% of total energy intake; protein accounted for 13%; fat provided 16%. Energy intake was divided among breakfast, lunch, dinner and snacks in a percentage ration of 19:26:21:34. The lunch, and snacks which were served at the day care center provided 36.5~79.1% of daily energy and nutrient intake. The survey clarified that the day care feding largely supplemented the inadequate dietary intakes of these young children at home. According to factor analysis of energy and nutrient intake, there were two factor groups : the first factor group, for energy, protein, carbohydrate, iron and niacin, mainly provided by grains; and the second factor group, for calcium, vitamin A, thamin, riboflavin and ascorbic acid, provided by vegetables, fruits, milk and milk products. The survey also revealed significant correlation coefficients between family factors such as family income, educational level of parents, and number of children; and dietary or nutritional status of the subjects.

  • PDF

Evaluation of UM-LDAPS Prediction Model for Daily Ahead Forecast of Solar Power Generation (태양광 발전 예보를 위한 UM-LDAPS 예보 모형 성능평가)

  • Kim, Chang Ki;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.71-80
    • /
    • 2019
  • Daily ahead forecast is necessary for the electricity balance between load and supply due to the variability renewable energy. Numerical weather prediction is usually employed to produce the solar irradiance as well as electric power forecast for more than 12 hours forecast horizon. UM-LDAPS model is the numerical weather prediction operated by Korea Meteorological Administration and it generates the 36 hours forecast of hourly total irradiance 4 times a day. This study attempts to evaluate the model performance against the in situ measurements at 37 ground stations from January to May, 2013. Relative mean bias error, mean absolute error and root mean square error of hourly total irradiance are averaged over all ground stations as being 8.2%, 21.2% and 29.6%, respectively. The behavior of mean bias error appears to be different; positively largest in Chupoongnyeong station but negatively largest in Daegu station. The distinct contrast might be attributed to the limitation of microphysics parameterization for thick and thin clouds in the model.

The Energy Absorption Characteristics of Thin-walled Rectangular Tubes (박판 사각튜브의 에너지 흡수 특성)

  • 김천욱;한병기;원종진;임채홍
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.83-91
    • /
    • 1996
  • This paper investigates the energy absorption characteristics of thin-walled rectangular tubes. In the compact mode, the crushing process of a thin-walled tube is analyzed into 3 parts by the ratio of outward to inward fold length. The mean crush load and the half-wave folding length are determined by using minimum energy principle. The effective crush distance can be determined when half-wave folding length is known, and the number of folds is derived when crush distance is given. Thus when the crush distance is given, energy absorption capacity can be estimated with mean crush load and number of folds. And the theoretical value is proven experimentally.

  • PDF

Turbine Design for Turbo-compound System to Recover Exhaust Gas Energy Using 1-D Mean Line Flow Model (1-D Mean Line Flow Model을 이용한 엔진 배기에너지 회수를 위한 터보컴파운드 시스템용 터빈 설계)

  • Jang, Jinyoung;Yun, Jeong-Eui
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.74-81
    • /
    • 2016
  • The aim of this study was to find the initial design value of turbine blade for electrical type turbocompound system generating 10 kW. Turbocompound is one of the waste heat recovery system applying to internal combustion engine to recover exhaust gas energy that was about 30 % of total input energy. To design the turbine blade, 1-D mean line flow model was used. Exhaust gas temperature, pressure, flow rate and turbine rotating speed was fixed as primary boundary conditions. The velocity triangles was defined and used to determine the rotor inlet radius and width, the rotor outlet radius at shroud and radius at hub, the rotor flow angles and the number of blades.

Experimental Results of Turbulent Thermal Mixing Phenomena Using Sodium Parallel Jets

  • Lee, Y.B.;Park, S.K.;J.S. Hwang;Kim, Y.K.;H.Y. Nam
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.199-204
    • /
    • 1996
  • In the present the mean temperature and the temperature fluctuation of non-isothermal parallel liquid sodium jets were measured and analyzed changing the temperature difference and mean velocity of the hot and cold sodium. The sampling frequency and sampling time were 420Hz and three seconds, respectively. The wave-form characteristics were discussed in regard to the peak-to-peak amplitudes and the periods provided by a wave analysis. And also the correlations of the temperature fluctuation in rms value and the peak amplitude are derived. The overall mean accuracy ratios of the correlations are 1.07 and 1.08 with a standard deviation of 0.17 and 0.15, respectively.

  • PDF

Natural Convection from a Horisontal Conducting Tube with One Vertical Axial Fin. (단일수직(單一垂直)한 축방향(軸方向)의 핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流))

  • Chung, H.S.;Kwon, S.S.
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.60-69
    • /
    • 1986
  • Two-dimensional finite difference numerical analysis is used to study conjugate natural convection heat transfer from a horizontal conducting tube with one vertical axial fin. By increasing dimensionless fin length ($L_F$), the mean total Nusselt number of the upward fin is slightly less than that of the downward fin at $L_F\;{\le}\;0.18$ and is higher than that of the downward fin at $L_F\;>\;0.18$. However comparing the upward fin and the downward fin with the no fin, the mean total Nusselt numbers of downward fin and upward fin at $L_F=0.30$ are increased approximately 4.01% and 5.51%, respectively. As Rayleigh number, Prandtl number and Biot number increase, the mean total and the mean tube Nusselt numbers are increased, but as wall thickness increases, the mean total and the mean tube Nusselt numbers are decreased. As the fin conduction parameter increases, the mean total Nusselt number is slightly increased because of increasing the mean fin Nusselt number.

  • PDF

Evaluating the Output of Small-size Wind Power Generators Using Weibull Data (와이블데이터를 이용한 소형풍력발전기 출력에 대한 평가)

  • You, Ki-Pyo;Kim, Young-Moon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.95-104
    • /
    • 2012
  • This study purposed to predict wind energy for small size wind power generators at 50m above the ground in each area using mean wind speed data for 10 minutes collected from 2001 to 2011 by meteorological data in large cities having over 60% of 15 story (50m) or higher apartments including Seoul, Daejeon, Gwangju and Daegu representing the inland region, and Busan, Incheon and Ulsan representing the coastal region. In the results of analysis, we confirmed close agree ment between observatory weather data and probability density distribution obtained using Weibull's parameters, and this suggests that Weibull's parameter is applicable to the estimation of wind energy. Hourly output energy using the mean wind speed for 10 minutes and output energy obtained from Weibull's parameter showed an error less than 5%, and thus it was found that wind energy can be evaluated using Weibull's modulus.