• Title/Summary/Keyword: mean comfort

Search Result 310, Processing Time 0.023 seconds

Performance and Applicability of PMV-based and TS-based Building Thermal Controls (PMV, TS 기준 건물 열 환경 제어법의 성능 및 적용성 분석)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.430-440
    • /
    • 2011
  • The purpose of this study was to investigate the interactions between the thermal factors in existing thermal control methods and to find out the control logic that can create more comfortable thermal conditions. For it, four thermal control logics were developed:conventional temperature-based control; temperature-based and humidity-based control; PMV-based control; and TS-based control. Their performance was comparatively tested in the U.S. typical 5-story office building in two climate zones (Detroit, Michigan and Miami, Florida) for two seasons (winter and summer) incorporating IBPT (International Building Physics Toolbox) and Matlab/Simulink. Analysis on the thermal conditions and energy efficiency revealed that each control logic created comfortable conditions for their respective target, i.e., temperature, humidity, PMV or TS, but uncomfortable for others (e.g., temperature-based control logic maintained PMV or TS uncomfortably or vise versa). In addition, energy efficiency was significantly different by logics. In conclusion, it can be said that the overall thermal comfort can be improved by the adoption of the PMV and TS as a target variable and their economical benefits are expected in the hotter climate zones with the reduced cooling and dehumidifying energy consumptions.

A Study on the Noise Level and Patients' Perception of the Noise in Emergency Department (응급실의 소음도와 환자의 인지정도에 관한 연구)

  • Chung Seung-Eun;Choi Chang-Ha
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.341-352
    • /
    • 1998
  • The purpose of this study was to provide a bases for comfort of patient through of measuring the noise level in emergency room and grasping the perception to noise of inpatient. Data on noise level through sound level meter in ER and patients' perception of the noise through a structured questionnaire and were collected from August 21 to September 5 in 1998. And collected data were analyzed with SAS statistics progeam, descriptive statistic, t-test and ANOVA. The result of examination is as follows : 1. Among a noise level of measured highest was 64.6dB(A) in 'rounding of medical teams', the lowest was 54.8dB(A) in 'traffic noise from outside'. 2. The mean score of noise perception was 0.93. Among a kind of noise reported by the subjects, that which ranked highest was 'conversation of patients' caregiver and visitors'(1.75). The ranked lowest was 'noise of airconditioner'(0.59). 3. The relationship between perception of noise and subjects' characteristics was not significient. Therefore, based on this result, ways require to decrease the noise level in emergency department.

  • PDF

Analysis of Nursing Interventions used in Orthopedic Nursing Unit (정형외과 간호단위에 적용되는 간호중재 분석)

  • Kim Hye-Suk;Choi Soon-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.13 no.1
    • /
    • pp.33-41
    • /
    • 2006
  • Purpose: This study was done to identify the Domains, Classes, labels and nursing activities of nursing interventions used with 117 patients who were admitted to orthopedic nursing units. Method: Data were collected in January and February, 2004 using a computerized nursing process program that contained nursing diagnosis-outcome-intervention (NNN) linkages. The program was developed by the researcher. Frequencies and percentages were used in the analysis. Results: Sixty-five nursing intervention labels were identified. The Domains of the nursing interventions showed higher percentages for 'physiological: basic' (75.9%), 'physiological: complex' (12.9%), 'behavioral'(7.8%) 'family'(1.3%), and 'safety'(1.1%). The Classes of nursing interventions showed higher percentages for 'activity and exercise management'(30.8%), 'physical comfort promotion'(19.3%), 'immobility management'(14.5%), 'drug management'(8.1%), and 'coping assistance'(5.6%). Nursing intervention labels showed higher percentages for 'pain management'(14.7%), 'body mechanics promotion'(8.0%), 'exercise therapy : ambulation'(7.2%), 'splinting'(5.4%), and 'positioning'(5.1%). In the comparison of numbers between performed nursing activities and nursing activities of NIC according to nursing intervention label, the mean of combined rate was 52.3%. Conclusion: These findings will help in building of a standardized language for orthopedic nursing units and enhance the quality of nursing care.

  • PDF

LONGITUDINAL CLINICAL STUDY ON THE EFFICACY OF OSSEOINTEGRATED DENTAL IMPLANTS IN PARTIALLY EDENTULOUS KOREAN PATIENTS: AN 8-YEAR PROSPECTIVE STUDY

  • Han Dong-Hoo;Bae Hanna Eun-Kyong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.698-708
    • /
    • 2001
  • This study was to evaluate the clinical evidence for the success and the predictability of the osseointegrated dental implants in the partially edentulous Korean patients. 201 patients have received total of 502 Branemark implants, which were restored with either single or multiunit fixed superstructures at the Implants Clinic, Yonsei University Dental Hospital. The clinical and radiographic evaluations carried out on the patients for maximum 8 years were assessed annually for peri-implant inflammation, implant mobility (PTV), Plaque Index (PI), Gingival Index (GI), Bleeding on Probing (BOP), Keratinized Mucosa width and any changes in the surrounding bone level. The radiographs were taken at completion of the restoration, and annually thereafter. On the last recall appointments the patients filled a questionnaire consist of 29 questions in four categories. The cumulative non-failure rate of success was 93.9%. The first year mean bone loss was 0.3mm and less than 0.2mm annually thereafter. The periodontal parameters, keratinized tissue width and periotest values stabilized after initial changes in the first few years. The questionnaire has shown general satisfactory responses in all four aspect of dental implants treatment, including chewing efficacy, comfort, aesthetics and speech. The results support the predictability and success of the long-term rehabilitation of implant supported prostheses in partially edentulous Korean patients.

  • PDF

Layering Effects on Clothing Microclimate, Clothing Insulation and Physiological Responses

  • Park, Joonhee;Yoo, Shinjung
    • International Journal of Human Ecology
    • /
    • v.14 no.2
    • /
    • pp.93-103
    • /
    • 2013
  • This study investigated the relationship of clothing microclimate and physiological responses in order to examine the layering effects on the clothing microclimate as an index to predict clothing thermal insulation ($I_{cl}$). Experiments were conducted in a $15^{\circ}C$ environment on six physically active males. Increased clothing layers resulted in higher mean temperature inside the clothing ($\bar{T}_{cl}$) and $I_{cl}$. The $I_{cl}$ had a high correlation with: $\bar{T}_{cl}$ (r = 0.556), the difference between the innermost surface temperature and the outermost surface temperature at the chest (DST) (r = 0.549) and the temperature inside clothing at the abdomen (r = 0.478). $\bar{T}_{cl}$ had the highest correlation with the temperature inside clothing at the abdomen (r = 0.889). $\bar{T}_{cl}$ also had the highest correlation with $\bar{T}_{sk}$ (r = 0.860). The results showed that the relationship between $I_{cl}$ and $\bar{T}_{cl}$ was linear (p < .01). Thermal comfort had a negative correlation with $\bar{T}_{cl-thigh}$ (r=-0.411) and $\bar{T}_{cl}$ (r = -0.323) (p < .01.)

A Study on Wearing Conditions and Dissatisfaction with Breast Cap for Current Womens Swimsuits (여성 수영복용 브래스트캡의 착용실태 및 불만족도에 관한 연구)

  • 노정화;최혜선;도월희
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.7
    • /
    • pp.47-55
    • /
    • 2003
  • The purpose of this study was to provide information on how to improve the comfort and fit of womens swimsuits through analysis of the present wearing conditions and users complaints. In order to compile the information about dissatisfaction with the appropriateness of the fit of breast cap for swimsuits, a questionnaire was administered to 364 females (over 20 years old under 60 years old). The contents of the questionnaire consisted of questions such as the reasons for selecting to wear breast cap for swimsuits or not, size of brassiere and swimsuits, dissatisfaction with material, dissatisfaction with function of breast cap. The collected data were analyzed using the descriptive statistics value of frequencies and percentile value, mean, and so on by means of the SPSS WIN.10.0 program. The differences among age groups, body type groups by rohrer index, cup size and so on were compared using the chi-square test. Results of the survey responses about swimsuits breast caps: Most women have worn swimsuits with caps. According to the results, women who are older or overweight, or have larger breasts, or breasts which sag, as well as those who have had the experience of giving birth responded that they feel uncomfortable because of the slope of their breasts. Concerning complaints about the caps, 61% of respondents complained about the cap size and lack of correspondence with breast size, 56.8% expressed concern about the cap gap. There is significant difference in wearing reason of breast caps forswimsuits among age groups and many kinds of groups.

NUMERICAL STUDY ON PERFORMANCE ASSESSMENT AND INSTALLATION CONDITIONS OF AN AUTOMOTIVE AIR CLEANER (자동차용 공기청정기의 성능 평가 및 설치 조건 도출을 위한 수치해석적 연구)

  • Lee, Y.H.;Seo, J.W.;Park, J.H.;Choi, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.263-270
    • /
    • 2010
  • In this study, an air cleaner is considered to improve comfort, safety, and health of automobile passengers. The performance and installation conditions of the air cleaner have been studied to investigate their effects on the air quality in the cabin room using numerical analysis. A five-passenger sedan and a seven-passenger minivan that have comparatively large indoor volume have been considered. The distributions of the local mean age and the volume averaged age of indoor air are calculated according to the variation of the placement and the air flow of the air cleaner. In addition, a decrease of contamination concentration, especially VOCs(volatile organic compounds), by the air cleaner is numerically analyzed with time-accurate unsteady calculation to quantify the effect of the air cleaner on the indoor air quality. As a result, the effective installation and operation conditions of the air cleaner for the automobile cabin room could be suggested.

  • PDF

Physiological Responses of Cold Protective Clothing with Different clo Value (보온력 차이에 따른 방한복 상의의 인체착의 생리반응)

  • Lee, Jung-Sug;Kim, Hee-Eun;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.683-689
    • /
    • 2008
  • The purpose of this study was to investigate physiological responses such as rectal temperature, skin temperature, micro climate, sweat rate and subjective sensations using cold protective clothing with five different clo value. The clo value was measured by thermal manikin in windless condition. Healthy five 20's males volunteered as subjects for wearing trial experiment. The climate chamber was controlled at $50^{\circ}C$, 65% RH. The experiment consisted of repeated exercise and recovery periods. We found that the higher clo value has, the higher mean skin temperature, micro climate and sweat rate show. They felt warm and wet with higher insulation clothing. Thermal comfort increased in the last recovery period after exercise. There was significant difference between five cold protective clothing. In correlation analysis of clo value, it showed that correlation coefficient(r) values were more than 0.8. Therefore, in terms of clothing insulation, we found that correlation between thermal manikin experiment and wearing trial experiment was high. Clothing insulation could be variable according to many factors such as body movement, covering area, clothing gap, layering and design. Considering the body movement, we thought that insulation measurement need to carry out both thermal manikin experiment and wearing trial experiment.

Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space (천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성)

  • Sung, Sang-Chul;Kim, Hyouk-Soon;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF

A Study on the view of Housing of University Students (대학생의 주거관에 관한 연구)

  • An, Ok-Hee;Jung, Mi-Ran;Kim, Soon-Kyung
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.1
    • /
    • pp.67-78
    • /
    • 1999
  • The purpose of this study was to analyze the view of housing of university students. The view of housing was investigated in four stages - housing consciousness, resident opinion, ideal housing type and housing needs - in this study. The data were collected through the self-entry questionnaire designed for this study. The statistical analysis methods used in this study are frequencies, mean, percentage, {\chi}^2-test, factor analysis and t-test using the SPSS for Window (version 7.5). The results are as follows : 1) The major findings of the housing consciousness were that the university students preferred the detached house in the future. 2) The resident opinion of university students showed that the group space was more important than the private space. 3) In the ideal housing image, they wanted psychological and physical comfort from their houses. 4) The points of consideration when they select their future housing is classified of 5 factors : Indoor-outdoor environment, neighbourhood environment, investmental value, design and size of house.

  • PDF