• 제목/요약/키워드: maximum temperature rise

검색결과 223건 처리시간 0.03초

Steel Cord 생산을 위한 초고속 습식 신선 패스 설계 (Pass Design of wet-Drawing with Ultra High Speed for Steel Cord)

  • 황원호;이상곤;김병민;고우식
    • 소성∙가공
    • /
    • 제14권9호통권81호
    • /
    • pp.785-790
    • /
    • 2005
  • High-speed multi-pass wet wire drawing has become very common for production of high-carbon steel cord because of the increase in customer demand and production rates in real industrial fields. Although, the wet wire drawing process is performed at a high speed usually above 1000m/min, greater speed is required to improve productivity. However, in the high-carbon steel wire drawing process, the wire temperature rises greatly as the drawing speed increase. The excessive temperature rise makes the wire more brittle and finally leads to wire breakage. In this study, the variations in wire temperature during the multi-pass wet wire drawing process were investigated. A multi-pass wet wire drawing process with 21 passes, which is used to produce steel cord, was redesigned by considering the increase in temperature. Through a wet wire drawing experiment, it was possible to increase the maximum final drawing speed to 2000m/min.

참억새(Miscanthus)燃料의 着火溫度 및 燃燒熱量 (Catch-fire Temperature and Amount of Combustion-Heat on the Fuel of Miscanthus type)

  • Kim, Kwan-Soo;In-Soo Jang;Jae-Soon Lee
    • The Korean Journal of Ecology
    • /
    • 제18권4호
    • /
    • pp.483-491
    • /
    • 1995
  • This study examined the relationship among catch-fire, burning, maximum temperature (MT), amount of combustion-heat (ACH), and combustive time (CT) in heating temperature treated with the same amount of each organ of Miscanthus. In the survey sites, about 19% of the areaswere covered by Miscanthus types, and the dry weight of Miscanthus and debris on the ground were 1,164 and 178 g/㎡, respectively. At 350℃ and 400℃, the rise of temperature by Culm type (culms and ears) and Leaf type (leaves and debris) were 90℃ and 82℃, respectively. At 350℃, durning time (BT) of culms-200, ears-200, ears-200, leaves-200 and debris-200 was 0-10’30”, 0-07’40”, 0-04’20”and 0-02’40”, and that at 400℃ was 0-01’20”, 0-00’50” 0-00’35”and 0-00’30”, respectively. BT was shorter at higher temperatures, and BT of Leaf type was shorter than that of Culm type. The amount of samples consumed was as follows: Culm type (culms-200 and ears-200) was 14.6g and 12.6g more than Leaf type (leaves-200 and debris-200) at 350℃ and 400℃, respectively. The total amount of combustion-heat (TACH) of samples was 5,859.7 kcal. The amount of mean combustion-heat generated from sample at 350℃ and 400℃ differed little: 727.6 kcal (24.9%) at 350℃ and 737.3 kcal (26.0%) at 400℃.

  • PDF

원형관에서 수직상향유동 초임계압 $CO_2$의 대류열전달 상관식 개발 (Development of a correlation on the convective heat transfer of supercritical pressure $CO_2$ vertically upward flowing in a circular tube)

  • 강덕지;김환열;배윤영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.292-295
    • /
    • 2008
  • In a SCWR (SuperCritical pressure Water cooled Reactor), the coolant temperature initially at below the pseudo-critical temperature at the bottom of a reactor core increases as the coolant flows upward through the sub-channels of the fuel assemblies, and it finally becomes higher than the pseudo-critical temperature when it leaves the reactor core. At certain conditions, heat transfer deterioration occurs near the pseudo-critical temperature and it may cause a drastic rise of the fuel surface temperature resulting a fuel failure. Therefore, an accurate estimation of the heat transfer coefficient is very important for the thermal-hydraulic design of a reactor core. An experiment on heat transfer to the vertically upward flowing $CO_2$ at a supercritical pressure in a circular tube were performed at KAERI. The internal diameter of the test section is 6.32 mm, which corresponds to the hydraulic diameter of a sub-channel in the conceptional design proposed by KAERI. The test range of the mass flux is 285 to 1200 kg/m$^2$s and the maximum heat flux is 170 kW/m$^2$. The inlet pressure is maintained at 8.12 MPa, which is 1.1 times the critical pressure. A new correlation, which covers both the normal and deterioration heat transfer regimes was proposed and compared with the estimations by exiting correlations.

  • PDF

지하생활공간 화재시 풍속에 따른 열유동 특성 연구 (Experimental Study on Heat Flow According to the Wind Velocity in an Underground Life Space)

  • 김영노;석창목;김화중
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.61-68
    • /
    • 2007
  • 본 연구에서는 지하생활공간을 대상으로 풍속의 변화에 대한 축소모델 실험을 통하여 열유동 및 화재성상을 분석하였다. 풍속이 증가할수록 화재실의 온도상승 시간은 빨라지고, 실의 온도도 증가하였다. 그리고 풍속이 증가할수록 화재실의 개구부에서 최고온도를 나타내었다. 화재확산에 따른 열유동은 풍속이 증가할수록 와류확산을 촉진시켜 연기발생과 화염의 크기를 증가시키고, 인근실의 내부보다 통로에서 높은 온도분포를 나타내었다. 끝으로 지하생활공간의 화재시 열유동은 풍향과 풍속에 의해 화재확산이 결정되어지고 풍속이 증가할수록 온도증가와 감소는 빠르게 진행됨을 확인할 수 있었다.

차세대에너지시스템 구축을 위한 도시기상조건 시계열분석 (A Time Series Analysis on Urban Weather Conditions for Constructing Urban Integrated Energy System)

  • 김상옥;한경민;이정재;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.26-31
    • /
    • 2009
  • This study was analysed influence of urban higher temperature in Busan about time series analysis of AWS data. The results are as follows. (1) The temperature of Busan show min $13.2^{\circ}C$ ~max $15.8^{\circ}C$ by 50 years, it is on the rise. (2) The seasonal adjustment series, summer appeared min $17.5^{\circ}C$ ~max $28.9^{\circ}C$ with primitive series similarly. The winter was min $-11.4^{\circ}C$ ~max $17.9^{\circ}C$, the minimum temperature was more lowly than primitive series and maximum temperature was more higher than primitive series. The results, seasonal adjustment series is guessed with influence difference urban structural element beside seasonal factor. (3) Regional analytical result, January appeared with range of min 28% ~max 196% of the seasonal factor and August appeared min 90% ~ max 106%. One of the case which is of 100% or more of the seasonal factor January 12nd~17th, August appears at the 15~17th.

  • PDF

가정용 열병합 발전을 위한 스털링 엔진의 열원 온도 및 냉각수 유량에 따른 성능 실험 (Performance Measurements of A Stirling Engine for Household Micro Combined Heat and Power with Heat Source Temperatures and Cooling Flow Rates)

  • 심규호;김민기;이윤표;장선준
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2015
  • A Beta-type Stirling engine is developed and tested on the operation stability and cycle performance. The flow rate for cooling water ranges from 300 to 1500 ml/min, while the temperature of heat source changes from 300 to $500^{\circ}C$. The internal pressure, working temperatures, and operation speed are measured and the engine performance is estimated from them. In the experiment, the rise in the temperature of heat source reduces internal pressure but increases operation speed, and overall, enhances the power output. The faster coolant flow rate contributes to the high temperature limit for stable operation, the cycle efficiency due to the alleviated thermal expansion of power piston, and the heat input to the engine, respectively. The experimental Stirling engine showed the maximum power output of 12.1 W and the cycle efficiency of 3.0 % when the cooling flow is 900 ml/min and the heat source temperature is $500^{\circ}C$.

전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구 (An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error)

  • 이병욱;오용택;장한솔;최성경;조효림;성원석;김은정
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

PHYSIOLOGICAL RESPONSES, FEED INTAKE, URINE VOLUME AND SERUM OSMOLALITY OF AARDI GOATS DEPRIVED OF WATER DURING SPRING AND SUMMER

  • El-Nouty, F.D.;Al-Haidary, A.A.;Basmaeil, S.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권4호
    • /
    • pp.331-336
    • /
    • 1990
  • In order to evaluate the adaptability of Aardi goats to arid environment, 5 Aardi bucks were deprived of water for four days during spring and summer seasons. The rise in average maximum ambient temperature from $24.8^{\circ}C$ in spring to $35.8^{\circ}C$ in summer caused a significant rise in rectal temperature ($0.3^{\circ}C$), respiratory rate (62%), serum osmolaity (8%) and serum sodium concentration (17%). While, it resulted in a significant decline in dry matter intake (50%), urine volume (74%) and fecal water excretion (60%) compared with their values in spring, but had no significant effect on the volume of drinking water. At the end of the 4-days deprivation period during spring, respiratory rate, dry matter intake and urine volume were reduced by 18, 77 and 91% relative to their average in control goats. The corresponding reduction in summer were 58, 100 and 100%. Serum osmolaity was risen by 15% in spring deprived goats and 29% in summer deprived goats. Rectal temperature rose by a mean value of $1.3^{\circ}C$ only in goats deprived of water in summer. Percent of moisture in the feces declined from 64 in control goats, to 24% in water deprived goats during spring season. The corresponding values in summer were 25 and 6%. These responses of Aardi goats deprived of water in summer indicate that they possess a water economy mechanism enable them to tolerate infrequent drinking in hot-arid environment.

Enhancement of Dimensional Stability of Compressed Open Cell Rigid Polyurethane Foams by Thermo-Mechanical Treatment

  • Ahn, WonSool
    • Elastomers and Composites
    • /
    • 제50권1호
    • /
    • pp.30-34
    • /
    • 2015
  • Thermo-mechanical treatment process of a compressed open-cell rigid polyurethane foam (OC-RPUF), which was fabricated for the vacuum insulation panel (VIP), was studied to obtain an optimum condition for the dimensional stability by the relaxation of compressive stress. Thermo-mechanical deformation of the sample OC-RPUF was shown to occur from about $120^{\circ}C$. Yield stress of 0.36 MPa was shown at about 10% yield strain. And, densification of the foam started to occur from 75% compressive strain and could be continued up to max. 90%. Compression set of the sample restored after initial compression to 90% at room temperature was ca. 82%. Though the expansion occurred to about twice of the originally compressed thickness in case of temperature rise to $130^{\circ}C$, it could be overcome and the dimensional stability could be maintained if the constant load of 0.3 MPa was applied. As the result, a thermo-mechanical treatment process, i.e, annealing process at temperature of $130{\sim}140^{\circ}C$ for about 20 min as is the maximum compressed state at room temperature, should be required for dimensional stability as an optimum condition for the use of VIP core material.

YBCO Coated Conductor의 과전류 특성해석 (Analysis of Over-current Characteristics in YBCO Coated Conductor)

  • 이찬주;남관우;강형구;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF