• Title/Summary/Keyword: maximum storage ratio

Search Result 109, Processing Time 0.026 seconds

Effects of Formaldehyde to Urea Mole Ratio on Thermomechanical Curing of Urea-Formaldehyde Resin Adhesives

  • Park, Byung-Dae;Kim, Jae-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.76-86
    • /
    • 2007
  • This study was conducted to investigate the effects of formaldehyde to urea (F/U) mole ratio on thermomechanical curing of UF resin adhesives with different F/U mole ratios. Thermomechanical curing of these UF resin adhesives was characterized using parameters of dynamic mechanical analysis (DMA) such as the gel temperature, maximum storage modulus, and peak temperatures of storage and loss modulus. As the F/U mole ratio decreased, the gel temperature of UF resin adhesives increased. The maximum storage modulus as an indicator of the rigidity of UF resin adhesives decreased with decreasing F/U mole ratio. The peak temperature of tan $\delta$ increased with decreasing F/U mole ratio, indicating that the vitrification occurred faster for high F/U mole ratio of UF resin adhesives than for the one of lower F/U mole ratio. These results partially explained the reason why UF resin adhesives with lower F/U mole ratio resulted in relatively poor adhesion performance when they were applied.

Design of Detention Pond and Critical Duration of Design Rainfall in Seoul

  • Lee, Jong-Tae;Yoon, Sei-Eui;Lee, Jae-Joon
    • Korean Journal of Hydrosciences
    • /
    • v.5
    • /
    • pp.33-43
    • /
    • 1994
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribytion of the design rainfall, Huff's quartile method is used for the 9 cases of durations (ranges from 20 to 240 minutes) with ten years return period, and the ILLUDAS model is used for runoff analysis. The storage ratio, which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the criticalduration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watercheds with pump station in Seoul, of which the range of watershed area is 0.24~12.70$km^2$. The result of simulation shows that the duration which maximizes storage ratio is 30 and 60 minutes on the whole. It is also shown that the storage ratios of 2nd - and 3rd-quartile pattern are larger than those of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by the regression analysis between the maximum storage ratio and the peak ratio. This formula can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF

Prediction of practically chargeable cold energy in an ice storage system (빙축열시스템의 실질적인 최대 축열 가능량 예측)

  • Lee, D.-Y.;Kang, B.H.;Kim, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

A study on the Thermal Characteristics of a Thermal Storage Tank for using Gravels (자갈식 축열조의 축열특성에 관한 연구)

  • Park, Jung-Won;Park, Bong-Kyu;Ahn, Sang-Kyu
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.81-87
    • /
    • 1992
  • The purpose of this study was to investigate the fluid flow characteristics of heat storage in sensible heat storage system for use In cooling and heating of buildings. Heat storage material was gravels and experiments were performed in the condition of constant temperature. The experimental parameters were fluid velocity and size of gravels. The experimental results of the heat storage quantity and the heat storage efficiency by the variation of packing size and fluid velocity were as the follows : The maximum value of the heat storage capacity and heat storage efficiency and the minimum arriving time for maximum heat storage were observed when the packing ratio was 72.5% and the fluid velocity was 0.14m/s.

  • PDF

A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control (소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구)

  • Ahn, Tae-Jin;Park, Jong-Yoon;Lyu, Heui-Jeong;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.385-398
    • /
    • 2003
  • The concept of the effective storage ratio has been suggested to determine the size of detention pond by the previous researchers. The 11 pump - pond facilities in Dongdu-chun city were selected to analyze the critical duration for design rainfall and the storage ratio for each rainfall duration in this study It has been then found that the criteria of the maximum storage ratio is not reasonable for determining the size of detention pond because the difference of storage ratio with respect to each rainfall duration is too small. Moreover, since the size of pond compared with the pump capacity is not always big enough, the pump should be frequently operated, which may result in pump failure. Thus, the pond should be sufficiently sized to prevent the possibility of the pump failure due to frequent operation. According to the analyses for changing pump capacity, it has been found that if the function of the pond compared with the pump is concentrated, determining the size of pond based on the storage ratio is operationally feasible for even small basin. Thus, an improved procedure based on the storage ratio for determining the size of detention pond in small basin has been suggested. The results by the proposed procedure considering pump switching frequency may lead to reasonable pump operation. A simple linear programming model has been also adopted to figure out the relationship between pump capacity and pond size. It has been shown that the determination lot the size of detention pond based on conventional hydrologic flood routing in pond is feasible for only urban districts not rural areas.

Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank (관외착빙형 빙축열조의 방열성능 모델링)

  • Lee, Sang-Ryoul;Lee, Kyoung-Ho;Choi, Byoung-Youn;Han, Seong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

An experimental study on heat transfer characteristics in the ice storage system of ice-on-coil type with rectangular finned tube during freezing process (직사각형 휜이 부착된 관외착빙형 빙축열조에서 응고과정시 열전달 특성에 관한 연구)

  • Kwon, H.Y.;Koh, J.Y.;Jeong, B.Y.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.61-67
    • /
    • 2000
  • The purpose of this study is to improve heat transfer by attaching rectangular fins to tube. Experiments were carried out under the following conditions - Aspect ratio$(W_f/R_f)$ is 0.7, 1.2 and 1.8. Temperature conversion between high and low positions of water in the thermal storage appeared because maximum density point of water is about $4^{\circ}C$ and inlet direction of working fluid influenced conductive heat transfer Compared with the unfinned tube(bare tube), the rectangular tube increased the ice thermal storage energy and the ice thermal storage energy was increased as aspect ratio was increased.

  • PDF

A Numerical Study on the Hoop Tensile Test of Type IV High Aspect Ratio Hydrogen Storage Vessel (Type IV 고세장비 수소저장용기의 Hoop 인장 시험에 관한 수치해석적 연구)

  • MOONSIC PARK;JUNSOONG LEE;WONHO YOON;KYUNBUM PARK;HYEONGUK YUN;SUNGWOOK JOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.1
    • /
    • pp.32-37
    • /
    • 2023
  • In this study, in order to propose a integrity evaluation for type IV high aspect ratio hydrogen storage vessel, a numerical analysis of the hoop tensile test and pressure test was performed using FEM software, and the results of the actual physical property test were reviewed. The property test and numerical analysis were compared, and very similar results were obtained with deviations of maximum tensile strength of 4.75% and fiber direction stress of 5.39%.

Dynamic Prime Chunking Algorithm for Data Deduplication in Cloud Storage

  • Ellappan, Manogar;Abirami, S
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.4
    • /
    • pp.1342-1359
    • /
    • 2021
  • The data deduplication technique identifies the duplicates and minimizes the redundant storage data in the backup server. The chunk level deduplication plays a significant role in detecting the appropriate chunk boundaries, which solves the challenges such as minimum throughput and maximum chunk size variance in the data stream. To provide the solution, we propose a new chunking algorithm called Dynamic Prime Chunking (DPC). The main goal of DPC is to dynamically change the window size within the prime value based on the minimum and maximum chunk size. According to the result, DPC provides high throughput and avoid significant chunk variance in the deduplication system. The implementation and experimental evaluation have been performed on the multimedia and operating system datasets. DPC has been compared with existing algorithms such as Rabin, TTTD, MAXP, and AE. Chunk Count, Chunking time, throughput, processing time, Bytes Saved per Second (BSPS) and Deduplication Elimination Ratio (DER) are the performance metrics analyzed in our work. Based on the analysis of the results, it is found that throughput and BSPS have improved. Firstly, DPC quantitatively improves throughput performance by more than 21% than AE. Secondly, BSPS increases a maximum of 11% than the existing AE algorithm. Due to the above reason, our algorithm minimizes the total processing time and achieves higher deduplication efficiency compared with the existing Content Defined Chunking (CDC) algorithms.

The Hydrogen Storage Characteristics of Ti-Cr-V Alloys (Ti-Cr-V 합금의 수소저장 특성)

  • Cho, Sung-Wook;Han, Chang-Suck;Park, Choong-Nyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 1998
  • The crystal structures, the lattice parameters and the characteristics of hydrogen storage at 303K has been investigated in the ternary alloys of Ti-Cr-V system. All of these alloys, in the range of this study, have shown a bcc structure. The hydrogen storage capacities and the effective hydrogen storage capacities of the alloys were strongly dependant on the composition ratio of Ti/Cr, showing their maximum values at the Ti/Cr ratio of about 0.75. It was also found that the lattice parameters of the alloys increased linearly with an increase of the Ti/Cr ratio. The differences in affinities to hydrogen and lattice parameters of pure metal states of the three elements have been adopted in oder to explain the Ti/Cr ratio dependance of the lattice parameter and hydrogen storage capacity of the alloys.

  • PDF